{"id":8371,"date":"2025-09-29T11:08:32","date_gmt":"2025-09-29T11:08:32","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=8371"},"modified":"2025-09-29T11:08:32","modified_gmt":"2025-09-29T11:08:32","slug":"sm-sre-700-k9","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/sm-sre-700-k9\/","title":{"rendered":"SM-SRE-700-K9"},"content":{"rendered":"<table>\n<tbody>\n<tr>\n<td colspan=\"2\">\n<h3 style=\"text-align: center;\"><strong>SM-SRE-700-K9 Specifications<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Form factor<\/strong><\/p>\n<\/td>\n<td>\n<p>SM<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>CPU<\/strong><\/p>\n<\/td>\n<td>\n<p>Intel Core2 Solo, 1.86 GHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>DRAM<\/strong><\/p>\n<\/td>\n<td>\n<p>4 GB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Compact Flash memory<\/strong><\/p>\n<\/td>\n<td>\n<p>2-GB internal USB flash-memory module<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Hard disk<\/strong><\/p>\n<\/td>\n<td>\n<p>One 500-GB SATA<\/p>\n<p>5400 rpm (SRE 700)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Hot-swappable hard disk drive (HDD)<\/strong><\/p>\n<\/td>\n<td>\n<p>None<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>RAID support<\/strong><\/p>\n<\/td>\n<td>\n<p>None<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Internal network interfaces<\/strong><\/p>\n<\/td>\n<td>\n<p>Gigabit Ethernet connectivity to router backplane<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>External network interfaces<\/strong><\/p>\n<\/td>\n<td>\n<p>One USB connector<\/p>\n<p>One RJ-45 Gigabit Ethernet connector<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Router platforms<\/strong><\/p>\n<\/td>\n<td>\n<p>Cisco 2911, 2921, 2951, 3925, 3925E, 3945, and 3945E Integrated Services Routers<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Cisco IOS Software (on&nbsp;router)<\/strong><\/p>\n<\/td>\n<td>\n<p>Release 15.1(4)M<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Embedded hardware-based cryptography acceleration<\/strong><\/p>\n<\/td>\n<td>\n<p>No<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Applications<\/strong><\/p>\n<\/td>\n<td>\n<p>&bull; Cisco Unity Express<\/p>\n<p>&bull; Cisco UCS Express<\/p>\n<p>&bull; Cisco AXP<\/p>\n<p>&bull; Cisco WLC<\/p>\n<p>&bull; Cisco Wide Area Application Services (WAAS)<\/p>\n<p>&bull; Infoblox Core Network Services<\/p>\n<p>&bull; Cisco Prime Network Analysis Module (NAM)<\/p>\n<p>&bull; Cisco Unified SIP Proxy<\/p>\n<p>&bull; Cisco Unified Messaging Gateway (UMG)<\/p>\n<p>&bull; Cisco Survivable Remote Site Voicemail (SRSV)<\/p>\n<p>&bull; Sagemcom Fax over IP<\/p>\n<p>&bull; Tiani Spirit Medical Data Exchange Solution<\/p>\n<p>&bull; Orion Health Rhapsody Connect<\/p>\n<p>&bull; NetScout nGenius Integrated Agent<\/p>\n<p>&bull; BlueCat Adonis DNS\/DHCP and Proteus IPAM<\/p>\n<p>&bull; LogLogic MX-Virtual Appliance<\/p>\n<p>&bull; SecureLogix Voice Policy Firewall<\/p>\n<p>&bull; Open Text RightFax Fax over IP<\/p>\n<p>&bull; Visual Network Systems OmniPoint Element<\/p>\n<p>&bull; Uplogix Local Management Platform<\/p>\n<p>&bull; IndustryWeapon CommandCenterHD<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Power consumption (maximum)<\/strong><\/p>\n<\/td>\n<td>\n<p>35W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Dimensions (H x W x D)<\/strong><\/p>\n<\/td>\n<td>\n<p>1.58 x 7.44 x 7.5 in.<\/p>\n<p>(4 x 18.9 x 19.1 cm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Shipping dimensions (H x W x D with packaging)<\/strong><\/p>\n<\/td>\n<td>\n<p>9.5 x 7.5 x 2.5 in.<\/p>\n<p>(24.1 x 19.1 x 6.4 cm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Maximum weight<\/strong><\/p>\n<\/td>\n<td>\n<p>2.5 lb (1.1 kg)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Operating temperature<\/strong><\/p>\n<\/td>\n<td>\n<p>32 to 104&deg;F (0 to 40&deg;C) normal<\/p>\n<p>23 to 131&deg;F (-5 to +55&deg;C) short term<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Humidity<\/strong><\/p>\n<\/td>\n<td>\n<p>10 to 85% operating<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Altitude (operating)<\/strong><\/p>\n<\/td>\n<td>\n<p>104&deg;F (40&deg;C) at sea level<\/p>\n<p>104&deg;F (40&deg;C) at 6,000 ft (1,800m)<\/p>\n<p>86&deg;F (30&deg;C) at 13,000 ft (4,000m)<\/p>\n<p>27.2&deg;C (81&deg;F) at 15,000 ft (4,600m)<\/p>\n<p>Note: De-rate 34.5&deg;F (1.4&deg;C) per 1,000 ft above 6,000 ft (per 300m above 2,600m)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Temperature<\/strong><\/p>\n<\/td>\n<td>\n<p>-4 to 149&deg;F (-20 to +65&deg;C)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Relative humidity<\/strong><\/p>\n<\/td>\n<td>\n<p>5 to 95%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Altitude<\/strong><\/p>\n<\/td>\n<td>\n<p>15,000 ft (4,600m)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Safety<\/strong><\/p>\n<\/td>\n<td>\n<p>&bull; UL 60950-1, First Edition, Standard for safety for information technology equipment (US)<\/p>\n<p>&bull; CAN\/CSA-C22.2 No. 60950-1-03, Safety of information technology equipment including electrical business equipment (Canada)<\/p>\n<p>&bull; IEC 60950-1:2001, Safety of information technology equipment\/Second Edition -2005) (World-Wide)- 2&nbsp;nd&nbsp;Ed. 2005 (optional)<\/p>\n<p>&bull; EN 60950 -1:2001, Safety of information technology equipment (CENELEC; includes EU and EFTA)<\/p>\n<p>&bull; GB4943-2001, Safety of information technology equipment (PRC)<\/p>\n<p>&bull; AS\/NZS 60950-1, Safety of information technology equipment including electrical business equipment (Australia)<\/p>\n<p>&bull; NOM-019, Safety of data processing equipment (Mexico)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>EMC<\/strong><\/p>\n<\/td>\n<td>\n<p>Emission:<\/p>\n<p>&bull; 47 CFR Part 15 Class A<\/p>\n<p>&bull; CISPR22 Class A<\/p>\n<p>&bull; EN300386 Class A<\/p>\n<p>&bull; EN55022 Class A<\/p>\n<p>&bull; EN61000-3-2<\/p>\n<p>&bull; EN61000-3-3<\/p>\n<p>&bull; SD\/EMI (India)<\/p>\n<p>&bull; KN22 (Korea)<\/p>\n<p>&bull; VCCI Class I<\/p>\n<p>&bull; AS\/NZS CISPR 22 Class A<\/p>\n<p>Immunity:<\/p>\n<p>&bull; CISPR24<\/p>\n<p>&bull; EN300386<\/p>\n<p>&bull; EN50082-1<\/p>\n<p>&bull; EN55024<\/p>\n<p>&bull; SD\/EMI (India)<\/p>\n<p>&bull; KN22 (Korea)<\/p>\n<p>&bull; EN61000-6-1<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<table>< tbody > <\/p>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>SM-SRE-700-K9 Router Services Ready Engine<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td itemprop=\"description\">Cisco Service-Ready Mondule (SRE), Voicemail, wilreless controller, AXP, Intel Processor, Software controller, 500G hard disk, 4G memory<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":55605,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[661],"product_tag":[],"class_list":{"0":"post-8371","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-router-isr-g2-sm-ism-modules","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/8371","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=8371"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/55605"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=8371"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=8371"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=8371"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=8371"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}