{"id":6508,"date":"2025-09-29T10:57:48","date_gmt":"2025-09-29T10:57:48","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=6508"},"modified":"2025-09-29T10:57:49","modified_gmt":"2025-09-29T10:57:49","slug":"ce5810-24t4s-ei-b","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/ce5810-24t4s-ei-b\/","title":{"rendered":"CE5810-24T4S-EI-B"},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"601\">\n<h3 align=\"center\"><strong>CE5810-24T4S-EI-B Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">\n<p>Base-T Ports<\/p>\n<\/td>\n<td valign=\"top\">\n<p>&nbsp;24<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">\n<p>SFP+ Ports<\/p>\n<\/td>\n<td valign=\"top\">\n<p>&nbsp;4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">\n<p>QSFP+ Ports<\/p>\n<\/td>\n<td valign=\"top\">\n<p>&nbsp;&#8211;<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">\n<p>Switching Capacity<\/p>\n<\/td>\n<td valign=\"top\">\n<p>128 Gbit\/s<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">\n<p>Forwarding Rates<\/p>\n<\/td>\n<td valign=\"top\">\n<p>96 Mpps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">\n<p>Airflow Design<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Front-to-back or back-to-front<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" valign=\"top\" width=\"113\">\n<p>Device Virtualization<\/p>\n<\/td>\n<td valign=\"top\">\n<p>iStack&nbsp;<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Super Virtual Fabric (SVF)&nbsp;<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" valign=\"top\" width=\"113\">\n<p>Network Virtualization<\/p>\n<\/td>\n<td valign=\"top\">\n<p>M-LAG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>TRILL (CE5855 &amp; CE5850)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">\n<p>VM Awareness<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Agile Controller<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">\n<p>SDN<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Open Programmability System (OPS)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" valign=\"top\" width=\"113\">\n<p>Traffic Analysis<\/p>\n<\/td>\n<td valign=\"top\">\n<p>NetStream<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>sFlow<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" valign=\"top\" width=\"113\">\n<p>VLAN<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Adding access, trunk, and hybrid interfaces to VLANs<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Default VLAN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>QinQ<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>MUX VLAN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>GVRP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">\n<p>ACL<\/p>\n<\/td>\n<td valign=\"top\">\n<p>ingress: 2.25k<br \/> egress: 512<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" valign=\"top\" width=\"113\">\n<p>MAC Address Table<\/p>\n<\/td>\n<td valign=\"top\">\n<p>maximum: 32k<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Dynamic learning and aging of MAC addresses<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Static, dynamic, and black hole MAC address entries<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Packet filtering based on source MAC addresses<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>MAC address limiting based on ports and VLANs<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">\n<p>ARP (maximum)<\/p>\n<\/td>\n<td valign=\"top\">\n<p>8k<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">\n<p>IPv4 FIB (maximum)<\/p>\n<\/td>\n<td valign=\"top\">\n<p>12k<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" valign=\"top\" width=\"113\">\n<p>IP Routing<\/p>\n<\/td>\n<td valign=\"top\">\n<p>IPv4 routing protocols, such as RIP, OSPF, BGP, and IS-IS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>IPv6 routing protocols, such as RIPng, OSPFv3, IS-ISv6, and BGP4+&nbsp;(not supported by CE5855)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">\n<p>IPv6 FIB (maximum)<\/p>\n<\/td>\n<td valign=\"top\">\n<p>6k<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" valign=\"top\" width=\"113\">\n<p>IPv6<\/p>\n<\/td>\n<td valign=\"top\">\n<p>IPv6 Neighbor Discovery (ND)&nbsp;(not supported by CE5855)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Path MTU Discovery (PMTU)&nbsp;(not supported by CE5855)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>TCP6, ping IPv6, tracert IPv6, socket IPv6, UDP6, and Raw IP6<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">\n<p>Multicast FIB (maximum)<\/p>\n<\/td>\n<td valign=\"top\">\n<p>8k<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\" valign=\"top\" width=\"113\">\n<p>Multicast<\/p>\n<\/td>\n<td valign=\"top\">\n<p>IGMP, PIM-SM, PIM-DM, MSDP, and MBGP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>IGMP snooping<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>IGMP proxy<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Fast leave of multicast member interfaces<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Multicast traffic suppression<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Multicast VLAN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\" valign=\"top\" width=\"113\">\n<p>Reliability<\/p>\n<\/td>\n<td valign=\"top\">\n<p>LACP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>STP, RSTP, VBST, MSTP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>BPDU protection, root protection, and loop protection<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Smart Link and multi-instance<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>DLDP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>ERPS (G.8032)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>VRRP, VRRP load balancing, and BFD for VRRP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>BFD for BGP\/IS-IS\/OSPF\/Static route<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" valign=\"top\" width=\"113\">\n<p>QoS<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Traffic classification based on Layer 2 headers, Layer 3 protocols, Layer 4 protocols, and 802.1p priority<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Actions of ACL, CAR, re-marking, and scheduling<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Queue scheduling algorithms, including PQ, WRR, DRR, PQ + WRR, and PQ + DRR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Congestion avoidance mechanisms, including WRED and tail drop<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Traffic shaping<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\" valign=\"top\" width=\"113\">\n<p>Configuration and Maintenance<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Console, Telnet, and SSH terminals<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Network management protocols, such as SNMPv1\/v2c\/v3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>File upload and download through FTP and TFTP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>BootROM upgrade and remote upgrade<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>802.3az Energy Efficient Ethernet (EEE)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Hot patches<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>User operation logs<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Zero-Touch Provisioning (ZTP)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\" valign=\"top\" width=\"113\">\n<p>Security and Management<\/p>\n<\/td>\n<td valign=\"top\">\n<p>802.1x authentication<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Command line authority control based on user levels, preventing unauthorized users from using commands<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>DoS, ARP, and ICMP attack defenses<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Port isolation, port security, and sticky MAC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Binding of the IP address, MAC address, interface number, and VLAN ID<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Authentication methods, including AAA, RADIUS, and HWTACACS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Remote Network Monitoring (RMON)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">\n<p>Dimensions (W x D x H)<\/p>\n<\/td>\n<td valign=\"top\">\n<p>442 mm x 420 mm x 43.6 mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">\n<p>Weight (fully loaded)<\/p>\n<\/td>\n<td valign=\"top\">\n<p>8 kg (17.6 lb)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" valign=\"top\" width=\"113\">\n<p>Environmental Parameters<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Operating temperature: 0&deg;C to 40&deg;C (32&deg;F to 104&deg;F) (0m to 1,800m)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Storage temperature: -40&deg;C to 70&deg;C (-40&deg;F to 158&deg;F)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Relative humidity: 5%&nbsp;to 95%, non-condensing<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" valign=\"top\" width=\"113\">\n<p>Operating Voltage<\/p>\n<\/td>\n<td valign=\"top\">\n<p>&nbsp;AC: 90V to 290V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>DC: -38.4V to -72V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">\n<p>Maximum Power Consumption<\/p>\n<\/td>\n<td valign=\"top\">\n<p>68W<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<table>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td itemprop=\"description\">Huawei CE5810-24T4S-EI Switch (24-Port GE RJ45,4-Port 10G SFP+,2*FAN Box,Port-side Intaket,Without Power Module)<\/td>\n<\/tr>\n<\/table>","protected":false},"featured_media":54743,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[577],"product_tag":[],"class_list":{"0":"post-6508","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-huawei-switches-ce5800-series-huawei","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/6508","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=6508"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/54743"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=6508"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=6508"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=6508"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=6508"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}