{"id":6407,"date":"2025-09-29T10:57:18","date_gmt":"2025-09-29T10:57:18","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=6407"},"modified":"2025-09-29T10:57:19","modified_gmt":"2025-09-29T10:57:19","slug":"ce6810-48s4q-li-f","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/ce6810-48s4q-li-f\/","title":{"rendered":"CE6810-48S4Q-LI-F"},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<h3 align=\"center\"><strong>CE6810-48S4Q-LI-F Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>10G Base-T Ports<\/p>\n<\/td>\n<td valign=\"top\">\n<p>0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>SFP+ Ports<\/p>\n<\/td>\n<td valign=\"top\">\n<p>48<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>QSFP+ Ports<\/p>\n<\/td>\n<td valign=\"top\">\n<p>4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Switching Capacity<\/p>\n<\/td>\n<td valign=\"top\">\n<p>1.28 Tbit\/s<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Forwarding Rate<\/p>\n<\/td>\n<td valign=\"top\">\n<p>960 Mpps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Airflow Design<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Front-to-back or back-to-front<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" valign=\"top\">\n<p>Device Virtualization<\/p>\n<\/td>\n<td valign=\"top\">\n<p>iStack<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Super Virtual Fabric (SVF)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Network Virtualization<\/p>\n<\/td>\n<td valign=\"top\">\n<p>M-LAG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>VM Awareness<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Agile Controller<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" valign=\"top\">\n<p>Network Convergence<\/p>\n<\/td>\n<td valign=\"top\">\n<p>FCoE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>DCBX, PFC, and ETS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" valign=\"top\">\n<p>Programmability<\/p>\n<\/td>\n<td valign=\"top\">\n<p>OpenFlow<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>OPS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Puppet and OVSDB plugins released on open source websites (CE6810EI)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Linux container for open source and customization programming<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" valign=\"top\">\n<p>Traffic Analysis<\/p>\n<\/td>\n<td valign=\"top\">\n<p>NetStream<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>sFlow<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" valign=\"top\">\n<p>VLAN<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Adding access, trunk, and hybrid interfaces to VLANs<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Default VLAN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>QinQ<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>MUX VLAN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>GVRP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>ACL<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Ingress: 1,250<br \/> Egress: 500<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" valign=\"top\">\n<p>MAC Address Table<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Maximum: 128k<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Dynamic learning and aging of MAC addresses<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Static, dynamic, and blackhole MAC address entries<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Packet filtering based on source MAC addresses<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>MAC address limiting based on ports and VLANs<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>ARP (maximum)<\/p>\n<\/td>\n<td valign=\"top\">\n<p>1.5k<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>IPv4 FIB (maximum)<\/p>\n<\/td>\n<td valign=\"top\">\n<p>1.5k<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" valign=\"top\">\n<p>IP Routing<\/p>\n<\/td>\n<td valign=\"top\">\n<p>IPv4 routing protocols, such as RIP, OSPF, BGP, and IS-IS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>IPv6 routing protocols, such as RIPng, OSPFv3, IS-ISv6, and BGP4+ (CE6810EI)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>IPv6 FIB (maximum)<\/p>\n<\/td>\n<td valign=\"top\">\n<p>\/<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Multicast FIB (maximum)<\/p>\n<\/td>\n<td valign=\"top\">\n<p>\/<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Multicast<\/p>\n<\/td>\n<td valign=\"top\">\n<p>IGMP snooping<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\" valign=\"top\">\n<p>Reliability<\/p>\n<\/td>\n<td valign=\"top\">\n<p>LACP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>STP, RSTP, VBST, MSTP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>BPDU protection, root protection, and loop protection<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Smart Link and multi-instance<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>DLDP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>ERPS (G.8032)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>VRRP, VRRP load balancing, and BFD for VRRP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" valign=\"top\">\n<p>QoS<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Traffic classification based on Layer 2 headers, Layer 3 protocols, Layer 4 protocols, and 802.1p priority<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Actions of ACL, CAR, re-marking, and scheduling<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Queue scheduling algorithms, including PQ, WRR, DRR, PQ + WRR, and PQ + DRR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Congestion avoidance mechanisms, including WRED and tail drop<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Traffic shaping<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\" valign=\"top\">\n<p>Configuration and Maintenance<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Console, Telnet, and SSH terminals<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Network management protocols, such as SNMPv1\/v2c\/v3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>File upload and download through FTP and TFTP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>BootROM upgrade and remote upgrade<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>802.3az Energy Efficient Ethernet (EEE)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Hot patches<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>User operation logs<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>ZTP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\" valign=\"top\">\n<p>Security and Management<\/p>\n<\/td>\n<td valign=\"top\">\n<p>802.1x authentication<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Command line authority control based on user levels, preventing unauthorized users from using commands<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>DoS, ARP, and ICMP attack defenses<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Port isolation, port security, and sticky MAC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Binding of the IP address, MAC address, interface number, and VLAN ID<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Authentication methods, including AAA, RADIUS, and HWTACACS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Remote Network Monitoring (RMON)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Dimensions (W x D x H)<\/p>\n<\/td>\n<td valign=\"top\">\n<p>442 mm x 600 mm x 43.6 mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Weight (fully loaded)<\/p>\n<\/td>\n<td valign=\"top\">\n<p>10.4 kg (22.9 lb)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Environmental Parameters<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Operating temperature: 0&deg;C to 40&deg;C (32&deg;F to 104&deg;F) (0m to 1,800m)<br \/> Storage temperature: -40&deg;C to 70&deg;C (-40&deg;F to 158&deg;F)<br \/> Relative humidity: 5% RH to 95% RH, non-condensing<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Operating Voltage<\/p>\n<\/td>\n<td valign=\"top\">\n<p>AC: 90V to 290V<br \/> DC: -38.4V to -72V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Max. Power Consumption<\/p>\n<\/td>\n<td valign=\"top\">\n<p>238W<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<table>< tbody > <\/p>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>CE6810-48S4Q-LI-F Huawei CE6800 Series Data Center Switch<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td itemprop=\"description\">CE6810-48S4Q-LI Switch(48-Port 10G SFP+,4-Port 40GE QSFP+,2*FAN Box,Port-side Exhaust,Without Power Module)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":54708,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[579],"product_tag":[],"class_list":{"0":"post-6407","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-huawei-switches-ce6800-series-huawei","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/6407","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=6407"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/54708"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=6407"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=6407"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=6407"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=6407"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}