{"id":5940,"date":"2025-09-29T10:54:33","date_gmt":"2025-09-29T10:54:33","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=5940"},"modified":"2025-09-29T10:54:33","modified_gmt":"2025-09-29T10:54:33","slug":"asr-9001","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/asr-9001\/","title":{"rendered":"ASR-9001"},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<h3 align=\"center\"><strong>ASR-9001 Specifications<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Type<\/td>\n<td valign=\"top\">Cisco ASR 9001 Chassis<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Integrated interfaces<\/td>\n<td valign=\"top\">4 x 10 GE SFP+<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Modular port adapters<\/td>\n<td valign=\"top\">20 x 1 GE, 2 x 10 GE, 4 x 10 GE, 1 x 40 GE<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Redundancy<\/td>\n<td valign=\"top\">Power supply redundancy<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Power supply part number<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0A9K-750W-AC<\/p>\n<p>\u25cf\u00a0\u00a0A9K-750W-DC<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Physical specifications<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0Height: 3.472 inches (88.2 mm)<\/p>\n<p>\u25cf\u00a0\u00a0Width: 17.42 inches (442 mm)<\/p>\n<p>\u25cf\u00a0\u00a0Depth: 18.5 inches (470 mm)<\/p>\n<p>\u25cf\u00a0\u00a0Weight of chassis: 30.2032 lbs (13.7 kg)<\/p>\n<p>\u25cf\u00a0\u00a0Weight of chassis with two MPAs: 36.37623 lbs (16.5 kg)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Power inputs<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0Worldwide ranging AC (90-265V; 50-60 Hz)<\/p>\n<p>\u25cf\u00a0\u00a0Worldwide ranging DC (-40V to -72V)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Power consumption<\/td>\n<td valign=\"top\">425 watts typical, 525 watts maximum<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Environmental conditions<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0Operating temperature: 32 to 104\u00b0F (0 to 40\u00b0C)<\/p>\n<p>\u25cf\u00a0\u00a0Storage temperature: -40 to 167\u00b0F (-40 to 75\u00b0C)<\/p>\n<p>\u25cf\u00a0\u00a0Relative humidity: 10 to 90%, noncondensing<\/p>\n<p>\u25cf\u00a0\u00a0Regulatory compliance<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<p align=\"center\"><strong>Environmental Specifications<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Operating temperature (nominal)<\/td>\n<td valign=\"top\">41 to 104\u00baF (5 to 40\u00baC)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Operating temperature<br \/>\n(short-term)<\/td>\n<td valign=\"top\">23 to 131\u00baF (-5 to 55\u00baC)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Operating humidity (nominal) (relative humidity)<\/td>\n<td valign=\"top\">10 to 85%<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Operating humidity<br \/>\n(short-term)<\/td>\n<td valign=\"top\">5 to 90%<br \/>\nNote: Not to exceed 0.024 kg water or dry air<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Storage temperature<\/td>\n<td valign=\"top\">-40 to 158\u00baF (-40 to 70\u00baC)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Storage (relative humidity)<\/td>\n<td valign=\"top\">5 to 95%<br \/>\nNote: Not to exceed 0.024 kg water or dry air<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Operating altitude<\/td>\n<td valign=\"top\">-1800m<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Air flow<\/td>\n<td valign=\"top\">Side to side<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<p align=\"center\"><strong>Compliance<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Network Equipment Building Standards (NEBS)<\/td>\n<td valign=\"top\">Cisco ASR 9001 is designed to meet:<\/p>\n<p>\u25cf\u00a0\u00a0SR-3580: NEBS Criteria Levels (Level 3)<\/p>\n<p>\u25cf\u00a0\u00a0GR-1089-CORE: NEBS EMC and Safety<\/p>\n<p>\u25cf\u00a0\u00a0GR-63-CORE: NEBS Physical Protection<\/p>\n<p>\u25cf\u00a0\u00a0VZ.TPR.9205: Verizon TEEER<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">ETSI standards<\/td>\n<td valign=\"top\">Cisco ASR 9001 is designed to meet (qualification in progress):<\/p>\n<p>\u25cf\u00a0\u00a0EN300 386: Telecommunications Network Equipment (EMC)<\/p>\n<p>\u25cf\u00a0\u00a0ETSI 300 019 Storage Class 1.1<\/p>\n<p>\u25cf\u00a0\u00a0ETSI 300 019 Transportation Class 2.3<\/p>\n<p>\u25cf\u00a0\u00a0ETSI 300 019 Stationary Use Class 3.1<\/p>\n<p>\u25cf\u00a0\u00a0EN55022: Information Technology Equipment (Emissions)<\/p>\n<p>\u25cf\u00a0\u00a0EN55024: Information Technology Equipment (Immunity)<\/p>\n<p>\u25cf\u00a0\u00a0EN50082-1\/EN-61000-6-1: Generic Immunity Standard<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">EMC standards<\/td>\n<td valign=\"top\">Cisco ASR 9001 is designed to meet:<\/p>\n<p>\u25cf\u00a0\u00a0FCC Class A<\/p>\n<p>\u25cf\u00a0\u00a0ICES 003 Class A<\/p>\n<p>\u25cf\u00a0\u00a0AS\/NZS 3548 Class A<\/p>\n<p>\u25cf\u00a0\u00a0CISPR 22 (EN55022) Class A<\/p>\n<p>\u25cf\u00a0\u00a0VCCI Class A<\/p>\n<p>\u25cf\u00a0\u00a0BSMI Class A<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN 61000-3-2: Power Line Harmonics<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN 61000-3-3: Voltage Fluctuations and Flicker<\/p>\n<p>\u25cf\u00a0\u00a0EN 50121-4: Railway EMC<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Immunity<\/td>\n<td valign=\"top\">Cisco ASR 9001 is designed to meet:<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN-61000-4-3: Radiated Immunity (10V\/m)<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN-61000-4-5: Signal Ports (1kV)<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN-61000-4-5: Surge DC Port (1kV)<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A\/m)<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations<\/p>\n<p>\u25cf\u00a0\u00a0EN 50121-4: Railway EMC<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Safety<\/td>\n<td valign=\"top\">Cisco ASR 9001 is designed to meet:<\/p>\n<p>\u25cf\u00a0\u00a0UL\/CSA\/IEC\/EN 60950-1<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN 60825 Laser Safety<\/p>\n<p>\u25cf\u00a0\u00a0ACA TS001<\/p>\n<p>\u25cf\u00a0\u00a0AS\/NZS 60950<\/p>\n<p>\u25cf\u00a0\u00a0FDA: Code of Federal Regulations Laser Safety<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>&lt; tbody &gt;<\/p>\n<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>ASR-9001 Cisco ASR 9001 Chassis<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>Cisco ASR 9001 Chassis ASR-9001 ASR 9001 Chassis<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":54470,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[546],"product_tag":[],"class_list":["post-5940","product","type-product","status-publish","has-post-thumbnail","product_cat-cisco-router-asr-9000-cisco-routers","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/5940","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=5940"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/54470"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=5940"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=5940"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=5940"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=5940"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}