{"id":4915,"date":"2025-09-29T10:47:33","date_gmt":"2025-09-29T10:47:33","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=4915"},"modified":"2025-09-29T10:47:33","modified_gmt":"2025-09-29T10:47:33","slug":"c9407r","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/c9407r\/","title":{"rendered":"C9407R="},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" align=\"center\">\n<h3 class=\"p\"><strong>Cisco Catalyst <a href=\"https:\/\/itnetworks.ae\/c9407r.html\" target=\"_blank\" rel=\"noopener\">C9407R<\/a> Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Total number of slots <a href=\"https:\/\/gntme.com\/product\/c9407r\/\" target=\"_blank\" rel=\"noopener\">C9407R<\/a><\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Line-card slots<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Supervisor engine slots<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">2<sup><br \/>\n<\/sup><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Dedicated supervisor engine slot numbers<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">3 and 4<sup><br \/>\n<\/sup><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Supervisor engine redundancy<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Supervisor engines supported<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p align=\"left\">C9400-SUP-1,<\/p>\n<p align=\"left\">C9400-SUP-1XL, C9400-SUP-1XL-Y<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Maximum PoE per slot<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">2880W<sup><br \/>\n<\/sup><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Maximum Bandwidth scalability per line-card slot<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">Up to 480 Gbps on all slots<sup><br \/>\n<\/sup><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Number of power supply bays<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>AC input power<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Integrated PoE<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Power supplies supported<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">3200W AC, 2100W AC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Number of fan-tray bays<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Location of 19-inch rack-mount<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">Front<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Dimensions (H x W x D)<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">17.41 x 17.30 x 16.30 in. (44.22 x 43.94 x 41.40cm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Rack Units (RU)<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">10 RU<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Chassis weight (with fan tray)<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">63.0 lb (28.58 kg)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Mounting<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">19-in rack compatible (19-in. rack and cable guide hardware included)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Regulatory compliance<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">CE Marking<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Safety<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\u25cf\u00a0\u00a0UL 60950-1<\/p>\n<p>\u25cf\u00a0\u00a0CAN\/CSA-C222.2 No. 60950-1<\/p>\n<p>\u25cf\u00a0\u00a0EN 60950-1<\/p>\n<p>\u25cf\u00a0\u00a0IEC 60950-1<\/p>\n<p>\u25cf\u00a0\u00a0AS\/NZS 60950.1<\/p>\n<p>\u25cf\u00a0\u00a0IEEE 802.3<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>EMC<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\u25cf\u00a0\u00a047 CFR Part 15<\/p>\n<p>\u25cf\u00a0\u00a0CISPR22 Class A<\/p>\n<p>\u25cf\u00a0\u00a0KN 32 Class A<\/p>\n<p>\u25cf\u00a0\u00a0EN 300 386 V1.6.1<\/p>\n<p>\u25cf\u00a0\u00a0EN 55022 Class A<\/p>\n<p>\u25cf\u00a0\u00a0EN 55032 Class A<\/p>\n<p>\u25cf\u00a0\u00a0CISPR 32 Class A<\/p>\n<p>\u25cf\u00a0\u00a0EN61000-3-2<\/p>\n<p>\u25cf\u00a0\u00a0EN61000-3-3<\/p>\n<p>\u25cf\u00a0\u00a0ICES-003 Class A<\/p>\n<p>\u25cf\u00a0\u00a0TCVN 7189 Class A<\/p>\n<p>\u25cf\u00a0\u00a0V-3 Class A<\/p>\n<p>\u25cf\u00a0\u00a0CNS13438 Class A<\/p>\n<p>\u25cf\u00a0\u00a0CISPR24<\/p>\n<p>\u25cf\u00a0\u00a0EN 300 386<\/p>\n<p>\u25cf\u00a0\u00a0EN55024<\/p>\n<p>\u25cf\u00a0\u00a0TCVN 7317<\/p>\n<p>\u25cf\u00a0\u00a0KN35<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>Industry EMC, safety, and environmental standards<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\u25cf\u00a0\u00a0NEBS: Operating temperature: -5 to 55C<\/p>\n<p>\u25cf\u00a0\u00a0Relative Humidity: 10-93%<\/p>\n<p>\u25cf\u00a0\u00a0Operating Altitude: up to 1829 m (6000 ft) at 55C<\/p>\n<p>\u25cf\u00a0\u00a0ETSI 300-019 Requirements are covered under GR-63-CORE with some deviations.<\/p>\n<p>\u25cf\u00a0\u00a0SR-3580 NEBS level 3 (GR-63-CORE, to current issue, GR-1089-CORE, to current issue)<\/p>\n<p>\u25cf\u00a0\u00a0ETS 300 019-2-1, Class 1.2 Storage<\/p>\n<p>\u25cf\u00a0\u00a0ETS 300 019-2-2, Class 2.3 Transportation<\/p>\n<p>\u25cf\u00a0\u00a0ETS 300 019-2-3, Class 3.2 Stationary<\/p>\n<p>\u25cf\u00a0\u00a0EN50121-4<\/p>\n<p>\u25cf\u00a0\u00a0EN 300 386<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\"><strong>ROHS compliance<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"281\">\n<p class=\"p\">ROHS5<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>C9407R= &#8211; Cisco Switch Catalyst 9400<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>Cisco Catalyst 9400 Series 7 slot chassis Spare<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":54035,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[530],"product_tag":[],"class_list":{"0":"post-4915","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-switches-cisco-switch-catalyst-9400-cisco","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/4915","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=4915"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/54035"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=4915"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=4915"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=4915"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=4915"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}