{"id":4467,"date":"2025-09-29T10:45:08","date_gmt":"2025-09-29T10:45:08","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=4467"},"modified":"2025-09-29T10:45:08","modified_gmt":"2025-09-29T10:45:08","slug":"n9k-c92160yc-x","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/n9k-c92160yc-x\/","title":{"rendered":"N9K-C92160YC-X"},"content":{"rendered":"<h3><span data-sheets-value=\"\"><a href=\"https:\/\/itnetworks.ae\/n9k-c92160yc-x.html\" target=\"_blank\" rel=\"noopener\">N9K-C92160YC-X<\/a> Datasheet<\/span><\/h3>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>N9K-C92160YC-X Datasheet Switches Cisco Nexus<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">We at <a href=\"https:\/\/gntme.com\/product-category\/cisco\/cisco-switches\/\" target=\"_blank\" rel=\"noopener\">Gntme<\/a>, furnish you with the highest Cisco network Series that you can purchase. We comprehend that switches are the establishment of most business organizations, and how essential they are for your working environment. Through Cisco Switches, gadgets associated with your organization can speak with each other and furthermore with different organizations proficiently, much the same as the Internet.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">The Cisco Nexus\u00ae 9200 stage is the furthest down the line expansion to the <a href=\"https:\/\/gntme.com\/?s=Cisco+Nexus+9000+Series+Switches&amp;search_id=1&amp;post_type=product\" target=\"_blank\" rel=\"noopener\">Cisco Nexus 9000 Series Switches<\/a>. The Cisco Nexus 9200 stage comprises industry-driving ultra-thickness fixed-design server farm switches with line-rate Layer 2 and 3 highlights that help undertaking and business applications, specialist co-op facilitating and distributed computing conditions. These N9K-C92160YC-X switches uphold a wide scope of port rates with adaptable blends of 1\/10\/25\/40\/50\/100-Gbps availability in reduced structure factors. <\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Utilizing the broadly conveyed industry-driving Cisco\u00ae NX-OS Software working framework, the <a href=\"https:\/\/gntme.com\/product-category\/cisco\/cisco-switches\/cisco-switch-catalyst-9200\/\" target=\"_blank\" rel=\"noopener\">Nexus 9200 switch<\/a> is intended for the programmable texture, which offers adaptability, versatility, and scale for specialist co-ops and IaaS\/cloud suppliers; and for the programmable organization which mechanizes design and the executives for clients who need to exploit the DevOps kind of working model and toolsets.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><a class=\"Hyperlink BCX0 SCXW187574036\" href=\"https:\/\/gntme.com\/\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"TextRun Underlined BCX0 SCXW187574036\" lang=\"EN-GB\" xml:lang=\"EN-GB\" data-contrast=\"none\"><span class=\"NormalTextRun BCX0 SCXW187574036\" data-ccp-charstyle=\"Hyperlink\"><span data-sheets-value=\"\">N9K-C92160YC-X datasheet, <\/span>Cisco<\/span><\/span><\/a><span class=\"TextRun BCX0 SCXW187574036\" lang=\"EN-GB\" xml:lang=\"EN-GB\" data-contrast=\"none\"><span class=\"NormalTextRun BCX0 SCXW187574036\"> ONE Nexus N9K-C92160YC-X Datasheet switch-L3-hosted-48 x 10\/25 Gigabit SFP+ + 6 x 40 Gigabit QSFP+ (uplink)+ 4 x 100 Gigabit QSFP- rack mount (C1-N9K- C92160YC-X) The Cisco Nexus N9K-C92160YC-X Datasheet switch (N9K-C92160YC-X) is a 1 rack unit (RU) switch with 48 SFP+ downstream ports, supporting 1, 10 or 25 Gigabit speeds, six upstream ports, supporting 40 or 100 gigabits. Speed (40 Gb for all six ports and 100 Gb for up to four ports), two network management ports (RJ-45 and SFP+), one RS-232 console port for setting up the initial switch configuration, and one USB Port used to save or load switch configuration.<\/span><\/span><span class=\"EOP BCX0 SCXW187574036\" data-ccp-props=\"\">\u00a0<\/span><\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td style=\"width: 613.273px;\" colspan=\"2\">\n<h2 style=\"text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>N9K-C92160YC-X Datasheet Specification<\/strong><\/span><\/h2>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Ports<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">48 x 10- and 25-Gbps SFP+ and 6 QSFP+ ports (4 are 100-Gbps capable) N9K-C92160YC-X<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Supported speeds<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">1, 10, and 25 Gbps on SFP+ ports<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">10, 25, 40, and 100 Gbps on QSFP+ ports<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Port configuration<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">48 x 10\/25-Gbps ports for downlinks; 4 of the 6 uplink ports are 100-Gbps capable. Ports 50 and 52 can be individually configured into 1 x 100 Gbps, 4 x 10 Gbps, 4 x 25 Gbps, 1 x 40 Gbps, or 2 x 50 Gbps<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>CPU<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">2 cores<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>System memory<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">16G<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>SSD drive<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">24G<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Shared system buffer<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">20MB<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Management ports<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">2 ports: 1 RJ-45 and 1SFP<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>USB ports<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">1<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>RS-232 serial ports<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">1<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Power supplies (up to 2)<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">650W AC, 930W DC, or 1200W AC\/HVDC<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Typical power (AC)<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">10-Gbps mode: 150W<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">25-Gbps mode: 170W<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Maximum power (AC)<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">475W<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Input voltage (AC)<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">100 to 240V<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Input voltage (HVAC)<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">200 to 277V<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Input voltage (DC)<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u201340 to \u201372V DC (minimum and maximum) \u201348 to \u201360V DC (nominal)<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Input voltage (HVDC)<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">240 to 380V<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Frequency (AC)<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">50 to 60 Hz<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Fans<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">4<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Airflow<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Port-side intake and exhaust<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>MTBF (hours)<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">379,400<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Physical (H x W x D)<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">1.72 x 17.3 x 22.5 in. (4.4 x 43.9 x 57.1 cm)<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Acoustics<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">51.9 dBA at 40% fan speed, 56.2 dBA at 70% fan speed, and 66.0 dB at 100% fan speed<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>RoHS compliance<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Yes<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Number of longest prefix match (LPM) routes<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Default:\u00a06,000<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">LPM heavy mode:\u00a0650,000<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Number of IP host entries<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Default: 96,000<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">LPM heavy mode: 650,000<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Number of MAC address entries<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">92,000<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Number of multicast routes<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Shipping:\u00a08,000<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Maximum: 32,000<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Number of Interior Gateway Management Protocol (IGMP) snooping groups<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Shipping: 8,000<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Maximum: 32,000<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Number of access control list (ACL) entries<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Per slice\u00a0of the\u00a0forwarding engine:<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">4,000 ingress<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">2,000 egress Maximum: 8,000 ingress<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">4,000 egress Shipping: 7,164 ingress<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">3,580 egress<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Maximum number of VLANs<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">3,967<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Number of Virtual Routing and Forwarding (VRF) instances<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Shipping:\u00a01,000<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Maximum: 16,000<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Maximum number of links in a Port Channel<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">32<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Maximum number of ECMP paths<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">64<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Maximum number of ECMP groups<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">256<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Maximum number of ECMP members<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">64,000<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Maximum number of Port Channels<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">512<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Number of active SPAN sessions<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">4<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Number of VLAN\u2019s in Rapid per-VLAN Spanning Tree (RPVST) instances<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">3,967<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Number of Hot-Standby Router Protocol (HSRP) groups<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">490<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Number of Multiple Spanning Tree (MST) instances<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">64<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Maximum Number of VxLAN Tunnel Endpoints (VTEPs)<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">256<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Operating temperature<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">32 to 104\u00b0F (0 to 40\u00b0C)<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Nonoperating (storage) temperature<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">-40 to 158\u00b0F (-40 to 70\u00b0C)<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Humidity<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">5 to 95% (noncondensing)<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Altitude<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">0 to 13,123 ft (0 to 4000m)<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 168.182px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Weight (without power supplies or fans)<\/strong><\/span><\/td>\n<td style=\"width: 434.364px;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">14.12 lb (6.4 kg)<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Related: Product\u00a0<\/span><\/p>\n<ul style=\"text-align: justify;\">\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"1\" aria-setsize=\"-1\" data-aria-posinset=\"1\" data-aria-level=\"1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><a href=\"https:\/\/gntme.com\/product\/n9k-c9372px-e\/\" target=\"_blank\" rel=\"noopener\">N9K-C9372PX-E<\/a>\u00a0<\/span><\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"1\" aria-setsize=\"-1\" data-aria-posinset=\"2\" data-aria-level=\"1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><a href=\"https:\/\/gntme.com\/product\/n9k-c9372tx\/\" target=\"_blank\" rel=\"noopener\">N9K-C9372TX<\/a>\u00a0<\/span><\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"1\" aria-setsize=\"-1\" data-aria-posinset=\"3\" data-aria-level=\"1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><a href=\"https:\/\/gntme.com\/product\/n9k-c9372tx-e\/\" target=\"_blank\" rel=\"noopener\">N9K-C9372TX-E<\/a>\u00a0<\/span><\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"1\" aria-setsize=\"-1\" data-aria-posinset=\"4\" data-aria-level=\"1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><a href=\"https:\/\/gntme.com\/product\/n9k-c93108tc-ex\/\" target=\"_blank\" rel=\"noopener\">N9K-C93108TC-EX<\/a>\u00a0<\/span><\/li>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"1\" aria-setsize=\"-1\" data-aria-posinset=\"5\" data-aria-level=\"1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><a href=\"https:\/\/gntme.com\/product\/n9k-c9372px\/\" target=\"_blank\" rel=\"noopener\">N9K-C9372PX<\/a><\/span><\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><a href=\"https:\/\/gntme.com\/product-category\/cisco\/cisco-switches\/cisco-switch-catalyst-9200\/\" target=\"_blank\" rel=\"noopener\">The\u00a0CiscoNexus\u00a09200 platform<\/a>\u00a0is the latest member of the Cisco Nexus 9000 series of switches.\u00a0 The Cisco Nexus 9200 platform consists of industry-leading ultra-density fixed-configuration data\u00a0center\u00a0switches, with wire-speed Layer 2 and Layer 3 functions, supporting enterprise and commercial applications, service provider hosting, and cloud computing environments.\u00a0\u00a0\u00a0<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">These switches flexibly combine 1\/10\/25\/40\/50\/100-Gbps connectivity in a compact form factor to support various port speeds.\u00a0 The\u00a0<a href=\"https:\/\/gntme.com\/product-category\/cisco\/cisco-switches\/cisco-switch-catalyst-9200\/\" target=\"_blank\" rel=\"noopener\">Nexus 9200 switch<\/a>\u00a0uses the widely deployed industry-leading Cisco\u00ae NX-OS software operating system and is designed for programmable architectures, providing flexibility, mobility and scale for service providers and IaaS\/cloud providers. And the programmable network that realizes automatic configuration and management for customers who want to utilize DevOps-type operating models and tool sets.\u00a0<\/span><\/p>","protected":false},"excerpt":{"rendered":"<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>N9K-C92160YC-X Datasheet &#8211; Cisco Nexus 9000 Switches<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>Nexus 9K Fixed with 48p 10G SFP+ and 6p 40G OR 4p 100G<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>PDF Attachment:<\/p>\n<p><a href=\"https:\/\/gntme.com\/wp-content\/uploads\/2021\/04\/n9k-c92160yc-x-datasheet-converted.pdf\">n9k-c92160yc-x datasheet<\/a><\/p>","protected":false},"featured_media":53839,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[496],"product_tag":[],"class_list":{"0":"post-4467","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-switches-cisco-nexus-9000-series-cisco","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/4467","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=4467"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/53839"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=4467"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=4467"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=4467"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=4467"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}