{"id":4451,"date":"2025-09-29T10:44:55","date_gmt":"2025-09-29T10:44:55","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=4451"},"modified":"2025-09-29T10:44:56","modified_gmt":"2025-09-29T10:44:56","slug":"ws-c3560cx-12pc-s","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/ws-c3560cx-12pc-s\/","title":{"rendered":"WS-C3560CX-12PC-S"},"content":{"rendered":"<p><strong><a href=\"https:\/\/itnetworks.ae\/ws-c3560cx-12pc-s-catalyst-compact-switch.html\" target=\"_blank\" rel=\"noopener\">ws-c3560cx-12pc-s<\/a>,<\/strong> The Cisco Catalyst 3560-CX and 2960-CX series of compact switches help optimize network deployment. These Gigabit Ethernet (GbE) managed switches are ideal for high-speed data connections, Wi-Fi backhaul, and Power over Ethernet (PoE) connections where space is at a premium. Catalyst compact switches provide IP connections for devices such as IP phones, wireless access points, surveillance cameras, PCs, and video terminals through a single copper or optical cable in the wiring closet.<\/p>\n<p>With a quiet, fanless design and compact size, these switches provide flexible installation options and open up a variety of network design and connection options. Use them in offices, classrooms, hotels, retail stores and other branches and enterprises. This configuration allows shortening of cable lines from compact switches, allowing space redesign and increased flexibility when new equipment is added to the network, eliminating the need for inflexible and expensive wiring infrastructure.<\/p>\n<h3><strong>The<\/strong> <strong>Accessories<\/strong><\/h3>\n<ol>\n<li><a href=\"https:\/\/gntme.com\/cab-console-rj45\/\" target=\"_blank\" rel=\"noopener\">CAB-CONSOLE-RJ45<\/a><\/li>\n<li><a href=\"https:\/\/gntme.com\/glc-lh-sm\/\" target=\"_blank\" rel=\"noopener\">GLC-LH-SM<\/a><\/li>\n<li><a href=\"https:\/\/gntme.com\/glc-sx-mmd\/\" target=\"_blank\" rel=\"noopener\">GLC-SX-MMD<\/a><\/li>\n<\/ol>\n<table border=\"1\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"553\">\n<h3 align=\"center\"><strong>WS-C3560CX-12PC-S Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Ethernet Ports<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">12 x 10\/100\/1000 Gigabit Ethernet<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>PoE<br \/>\nOutput Ports<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">12 PoE+<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Available<br \/>\nPoE Power<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">240W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Uplinks<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p class=\"pchartbodycmt\">2 x 1G copper plus<\/p>\n<p class=\"pchartbodycmt\">2 x 1G SFP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Default Software<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">IP Base (IP Services with RTU License)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Powering Option<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">Internal power supply<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Available PoE Power (W)<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">240W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Can Switch Be Powered with Uplinks?<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">No<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Forwarding Bandwidth<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">16 Gbps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Switching Bandwidth (full-duplex capacity)<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">32 Gbps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Flash memory<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">128 MB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Memory DRAM<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">512 MB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Max VLANs<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">1023<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>VLAN IDs<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">4000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Maximum transmission unit (MTU)<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">Up to 9000 bytes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Jumbo frames<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">9198 bytes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Forwarding rate 64 Byte Packet\u00a0<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">23.8 mpps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Dimensions<br \/>\n(H x W x D)<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">1.75 x 10.6 x 9.4 in (4.44 x 26.9 x 23.8 cm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Weight<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">5.1 lb (2.31 Kg)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Operating*\u00a0temperature up to 5000 ft (1524 m)<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">-5\u00b0C to +45\u00b0C (+23\u00b0F to +113\u00b0F)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Operating*\u00a0temperature up to 10,000 ft (3048 m)<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">-5\u00b0C to +45\u00b0C (+23\u00b0F to +113\u00b0F)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Storage temperature up to 15,000 ft (4572 m)<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">-25\u00b0C to +70\u00b0C (-13\u00b0F to +158\u00b0F)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Operating altitude<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">Up to 3048 m (Up to 10,000 ft)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Storage altitude<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">Up to 4000 m (Up to 15,000 ft)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Operating relative humidity<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">5% to 95% noncondensing<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Storage relative humidity<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">5% to 95% noncondensing<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>MTBF<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">553,140<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Management<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">\u25cf\u00a0 BRIDGE-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-CABLE-DIAG-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-CDP-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-CLUSTER-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-CONFIG-COPY-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-CONFIG-MAN-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-DHCP-SNOOPING-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-ENTITY-VENDORTYPE-OID-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-ENVMON-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-ERR-DISABLE-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-FLASH-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-FTP-CLIENT-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-IGMP-FILTER-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-IMAGE-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-IP-STAT-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-LAG-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-MAC-NOTIFICATION-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-MEMORY-POOL-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-PAGP-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-PING-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-POE-EXTENSIONS-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-PORT-QOS-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-PORT-SECURITY-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-PORT-STORM-CONTROL-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-PRODUCTS-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-PROCESS-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-RTTMON-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-SMI-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-STP-EXTENSIONS-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-SYSLOG-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-TC-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-TCP-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-UDLDP-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-VLAN-IFTABLE<\/p>\n<p align=\"left\">\u25cf\u00a0 RELATIONSHIP-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-VLAN-MEMBERSHIP-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 CISCO-VTP-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 ENTITY-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 ETHERLIKE-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 IEEE8021-PAE-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 IEEE8023-LAG-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 IF-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 INET-ADDRESS-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 OLD-CISCO-CHASSIS-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 OLD-CISCO-FLASH-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 OLD-CISCO-INTERFACES-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 OLD-CISCO-IP-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 OLD-CISCO-SYS-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 OLD-CISCO-TCP-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 OLD-CISCO-TS-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC1213-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 RMON-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 RMON2-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 SNMP-FRAMEWORK-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 SNMP-MPD-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 SNMP-NOTIFICATION-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 SNMP-TARGET-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 SNMPv2-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 TCP-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 UDP-MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 ePM MIB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Standards<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">\u25cf\u00a0\u00a0IEEE 802.1D Spanning Tree Protocol<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0IEEE 802.1p CoS Prioritization<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0IEEE 802.1Q VLAN<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0IEEE 802.1s<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0IEEE 802.1w<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0IEEE 802.1x<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0IEEE 802.1AB (LLDP)<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0IEEE 802.3ad<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0IEEE 802.3af<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0IEEE 802.3ah<br \/>\n(100BASE-X single\/multimode fiber only)<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0IEEE 802.3 10BASE-T specification<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0IEEE 802.3u 100BASE-TX specification<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0IEEE 802.3ab 1000BASE-T specification<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0IEEE 802.3z 1000BASE-X specification<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0100BASE-BX (SFP)<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0100BASE-FX (SFP)<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0100BASE-LX (SFP)<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a01000BASE-BX (SFP)<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a01000BASE-SX (SFP)<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a01000BASE-LX\/LH (SFP)<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a01000BASE-ZX (SFP)<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a01000BASE-CWDM SFP 1470 nm<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a01000BASE-CWDM SFP 1490 nm<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a01000BASE-CWDM SFP 1510 nm<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a01000BASE-CWDM SFP 1530 nm<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a01000BASE-CWDM SFP 1550 nm<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a01000BASE-CWDM SFP 1570 nm<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a01000BASE-CWDM SFP 1590 nm<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a01000BASE-CWDM SFP 1610 nm<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0RMON I and II standards<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0SNMPv1, SNMPv2c, and SNMPv3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>RFC compliance<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">\u25cf\u00a0 RFC 768: UDP<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 783: TFTP<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 791: IP<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 792: ICMP<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 793: TCP<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 826: ARP<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 854: Telnet<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 951: Bootstrap Protocol<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1542: BOOTP Extensions<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 959: FTP<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1058: RIP Routing<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1112: IP Multicast and IGMP<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1157: SNMPv1<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1166: IP Addresses<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1253: OSPF Routing<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1256: ICMP Router Discovery<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1305: NTP<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1492: TACACS+<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1493: Bridge MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1542: Bootstrap Protocol<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1583: OSPFv2<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1643: Ethernet Interface MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1723: RIPv2 Routing<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1757: RMON<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1812: IP Routing<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1901: SNMPv2C<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1902-1907: SNMPv2<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 1981: MTU Path Discovery IPv6<\/p>\n<p align=\"left\">\u25cf\u00a0 FRC 2068: HTTP<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 2080: RIP for IPv6<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 2131: DHCP<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 2138: RADIUS<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 2233: IF MIB<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 2236: IP Multicast<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 2328: OSPFv2<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 2273-2275: SNMPv3<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 2373: IPv6 Aggregatable Addrs<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 2453: RIPv2 Routing<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 2460: IPv6 protocol<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 2461: IPv6 Neighbor Discovery<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 2462: IPv6 Autoconfiguration<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 2463: ICMP IPv6<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 2474: DiffServ Precedence<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 2597: Assured Forwarding<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 2598: Expedited Forwarding<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 2571: SNMP Management<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 2740: OSPF for IPv6<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 3046: DHCP Relay Agent Information Option<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 3101, 1587: NSSAs<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 3376: IGMPv3<\/p>\n<p align=\"left\">\u25cf\u00a0 RFC 3580: 802.1x RADIUS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Safety standards<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">\u25cf\u00a0\u00a0UL 60950-1<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0CAN\/CSA 22.2 No. 60950-1<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0EN 60950-1<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0IEC 60950-1<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0CE Marking<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0GB 4943<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0IEC 60825<\/p>\n<p align=\"left\">\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Electromagnetic emissions certifications<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">\u25cf\u00a0\u00a0FCC Part 15, CFR 47, Class A, North America<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0EN\/IEC 61000-4-5<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0EN 55022 (CISPR22) and EN 55024 (CISPR24), CE marking, European Union<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0AS\/NZS, Class A, CISPR22:2004 or EN55022, Australia and New Zealand<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0VCCI Class A, V-3\/2007.04, Japan<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0KCC (Formerly MIC, GB17625.1-1998) Class A, KN24\/KN22, Korea<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0ANATEL, Brazil<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0CCC, China<\/p>\n<p align=\"left\">\u25cf\u00a0\u00a0GOST, Russia<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Environmental<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">Reduction of Hazardous Substances (ROHS) 6<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\"><strong>Telco<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"277\">\n<p align=\"left\">Common Language Equipment Identifier (CLEI) code<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>","protected":false},"excerpt":{"rendered":"<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>WS-C3560CX-12PC-S Catalyst Compact switch<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>Cisco Catalyst 3560-CX 12-port compact Switch Layer 3, POE- 12 x 10\/100\/1000 Ethernet Ports, 2 SFP&amp;2GE uplinks- Data IP Base &#8211; Managed<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Datasheet: <a href=\"https:\/\/gntme.com\/wp-content\/uploads\/2020\/05\/WS-C3560CX-12PC-S-Datasheet.pdf\">WS-C3560CX-12PC-S Datasheet<\/a><\/p>","protected":false},"featured_media":53811,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[503],"product_tag":[],"class_list":{"0":"post-4451","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-switches-cisco-catalyst-compact-switch-cisco","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/4451","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=4451"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/53811"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=4451"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=4451"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=4451"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=4451"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}