{"id":4264,"date":"2025-09-29T10:44:15","date_gmt":"2025-09-29T10:44:15","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=4264"},"modified":"2025-09-29T10:44:15","modified_gmt":"2025-09-29T10:44:15","slug":"n9k-c9372tx","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/n9k-c9372tx\/","title":{"rendered":"N9K-C9372TX"},"content":{"rendered":"<h2 style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong><a href=\"https:\/\/itnetworks.ae\/n9k-c9372tx.html\" target=\"_blank\" rel=\"noopener\">N9K-C9372TX<\/a> &#8211; Buy Cisco Nexus 9000 Series Switch<\/strong><\/span><\/h2>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><a href=\"https:\/\/gntme.com\/\" target=\"_blank\" rel=\"noopener\">The Cisco Nexus<\/a> 9372TX Switch N9K-C9372TX is a 1RU switch that supports 1.\u00a0 The bandwidth of 48 fixed 10 Gbps BASE-T ports and 6 fixed 40 Gbps QSFP+ ports is 44\u00a0Tbps, which is more than 1150\u00a0mpps. Cisco Nexus 9372TX \/ 9327TX-E switches provide wire-speed Layer 2 and Layer 3 feature sets in a compact form factor.\u00a0<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">We at <a href=\"https:\/\/gntme.com\" target=\"_blank\" rel=\"noopener\">Gntme<\/a>, give you the highest Cisco network Series that you can purchase. We comprehend that switches are the establishment of most business organizations, and how critical they are for your working environment.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><span data-sheets-value=\"\">N9K-C9372TX datasheet, <\/span>We understand that switches are the foundation of most business networks, and how crucial they are for your workplace. Through <a href=\"https:\/\/gntme.com\/product-category\/cisco\/cisco-switches\/\" target=\"_blank\" rel=\"noopener\">Cisco switches<\/a>, devices connected to your network can communicate with one another and also with other networks efficiently, just like the Internet. There are essentially two sorts of switches you can look over as a feature of your systems administration nuts and bolts: on-premises and cloud-oversaw. The Cisco N9K-C9372TX Switch is a high-performance and scalable switches available in UAE<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><span data-sheets-value=\"\">N9K-C9372TX datasheet, <\/span>Associations wherever perceive that changing application conditions are making new requests for the IT framework that upholds them. Application outstanding burdens are sent across a blend of virtualized and nonvirtualized worker and capacity framework, requiring an organization foundation that gives steady availability, security, and permeability across a scope of exposed metal, virtualized, and distributed computing conditions:<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Application occasions are made powerfully. Thus, the provisioning, change, and evacuation of utilization network availability should be dynamic too.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Specialty units request quickened application organizations. IT offices need to give a shared IT framework to address time-to-showcase needs and to build their profit from speculation (ROI).<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">With associations conveying a blend of custom, open-source, and off-the-rack business applications, IT divisions should oversee both security and nature of administration (QoS) for conditions that help multitenancy.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Applications have been progressing after some time to a less solid, scale-out, multinode model. IT foundation that bolsters this model should scale with the speed of business and backing both 10 and 40 Gigabit Ethernet network.<\/span><\/p>\n<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<h3 align=\"center\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>N9K-C9372TX Specification<\/strong><\/span><\/h3>\n<p>&nbsp;<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Ports<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">48 fixed 1\/10GBASE-T and 6 QSFP+ ports ( N9K-C9372TX )<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Supported speeds<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">100 Megabit Ethernet and 1\/10 Gigabit Ethernet speeds<\/span><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">40 Gigabit Ethernet uplink port<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">6 fixed QSFP+ ports<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Advanced QSFP+ optics enable connectivity using existing 10 Gigabit Ethernet fiber.<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">The switch offers 25 MB of additional packet buffer space shared with all ports for more resilient operations.<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Power supplies (up to 2)<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">650W AC, 930W DC, or 1200W HVAC\/HVDC<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Typical power*(AC &amp; DC)<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">374.5W<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Maximum power*\u00a0(AC &amp; DC)<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">694W<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Input voltage (AC)<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">100 to 240V<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Input voltage (HVAC)<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">200 to 277V<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Input voltage (DC)<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">-40V to -72V DC (min-max)<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">-48V to -60V DC (nominal)<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Input voltage (HVDC)<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u2013240 to \u2013380V<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Frequency (AC)<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">50 to 60 Hz<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Fans<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">4<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Physical (H x W x D)<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">1.72 x 17.3 x 22.5 in. (4.4 x 43.9 x 57.1cm)<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Acoustics<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">48.6 dBA at 40% fan speed, 65.2 dBA at 70% fan speed, and 76.5 dB at 100% fan speed<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">RoHS compliance<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Yes<\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<p align=\"center\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Product Specifications<\/strong><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Maximum number of longest prefix match (LPM) routes<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">128,000*<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Maximum number of IP host entries<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">208,000*<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Maximum number of MAC address entries<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">96,000*<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Number of multicast routes<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a032,000 (without virtual PortChannel [vPC])<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a032,000 (with vPC)<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Number of Interior Gateway Management Protocol (IGMP) snooping groups<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a032,000 (without vPC)<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a032,000 (with vPC)<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Maximum number of Cisco Nexus 2000 Series Fabric Extenders per switch<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">16<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Number of access control list (ACL) entries<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a04000 ingress<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a01000 egress<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Maximum number of VLANs<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">4096<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Maximum number of Virtual Routing and Forwarding (VRF) instances<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">1000<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Maximum number of links in a PortChannel<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">32<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Maximum number of ECMP paths<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">64<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Maximum number of PortChannels<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">528<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Number of active SPAN sessions<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">4<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Maximum number of Rapid per-VLAN Spanning Tree (RPVST) instances<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">507<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Maximum number of Hot-Standby Router Protocol (HSRP) groups<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">490<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Maximum number of Multiple Spanning Tree (MST) instances<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">64<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Maximum number of VXLAN tunnel endpoints (VTEP)<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">256<\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<p align=\"center\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Environmental Properties<\/strong><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Operating temperature<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">32 to 104\u00b0F (0 to 40\u00b0C)<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Nonoperating (storage) temperature<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">-40 to 158\u00b0F (-40 to 70\u00b0C)<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Humidity<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">5 to 95% (noncondensing)<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Altitude<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">0 to 13,123 ft (0 to 4000m)<\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<p style=\"text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Weight<\/strong><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Cisco Nexus 9372PX\/9372PX-E without power supplies or fans<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">22.2 lb (10.1 kg)<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Cisco Nexus 9372TX\/9372TX-E without power supplies or fans<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">22.6 lb (10.25 kg)<\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<p align=\"center\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><strong>Safety and EMC<\/strong><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Regulatory compliance<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Products should comply with CE Markings according to directives 2004\/108\/EC and 2006\/95\/EC<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Safety<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0UL 60950-1 Second Edition<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0CAN\/CSA-C22.2 No. 60950-1 Second Edition<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0EN 60950-1 Second Edition<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0IEC 60950-1 Second Edition<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0AS\/NZS 60950-1<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0GB4943<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">EMC: Emissions<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a047CFR Part 15 (CFR 47) Class A<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0AS\/NZS CISPR22 Class A<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0CISPR22 Class A<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0EN55022 Class A<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0ICES003 Class A<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0VCCI Class A<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0EN61000-3-2<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0EN61000-3-3<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0KN22 Class A<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0CNS13438 Class A<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">EMC: Immunity<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0EN55024<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0CISPR24<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0EN300386<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">\u25cf\u00a0\u00a0KN 61000-4 series<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">RoHS<\/span><\/td>\n<td valign=\"top\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">The product is RoHS-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: justify;\" aria-level=\"3\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><b>The Accessories<\/b>\u00a0<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><b>Table 2 shows the recommended elements for the N9K-C9372TX.<\/b>\u00a0<\/span><\/p>\n<table data-tablestyle=\"MsoTableGrid\" data-tablelook=\"1696\">\n<tbody>\n<tr>\n<td data-celllook=\"4369\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><b>Category<\/b>\u00a0<\/span><\/td>\n<td data-celllook=\"273\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><b>Model<\/b>\u00a0<\/span><\/td>\n<td data-celllook=\"273\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><b>Description<\/b>\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"4\" data-celllook=\"4368\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">40G Transceiver and Cable Options\u00a0<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><b>\u00a0<\/b>\u00a0<\/span><\/td>\n<td data-celllook=\"272\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><a href=\"https:\/\/gntme.com\/product\/qsfp-h40g-acu10m\/\" target=\"_blank\" rel=\"noopener\">QSFP-H40G-ACU10M<\/a>\u00a0<\/span><\/td>\n<td data-celllook=\"272\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Cisco QSFP to QSFP copper direct-attach 40GBASE-CR4 cable QSFP-H40G-ACU10M\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"272\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><a href=\"https:\/\/gntme.com\/product\/qsfp-h40g-cu1m\/\" target=\"_blank\" rel=\"noopener\">QSFP-H40G-CU1M<\/a>\u00a0<\/span><\/td>\n<td data-celllook=\"272\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Cisco QSFP to QSFP copper direct-attach 40GBASE-CR4 cable QSFP-H40G-CU1M\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"272\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><a href=\"https:\/\/gntme.com\/product\/qsfp-h40g-cu3m\/\" target=\"_blank\" rel=\"noopener\">QSFP-H40G-CU3M<\/a>\u00a0<\/span><\/td>\n<td data-celllook=\"272\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Cisco QSFP to QSFP copper direct-attach 40GBASE-CR4 cable QSFP-H40G-CU3M\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"272\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"><a href=\"https:\/\/gntme.com\/product\/qsfp-h40g-cu5m\/\" target=\"_blank\" rel=\"noopener\">QSFP-H40G-CU5M<\/a>\u00a0<\/span><\/td>\n<td data-celllook=\"272\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\">Cisco QSFP to QSFP copper direct-attach 40GBASE-CR4 cable QSFP-H40G-CU5M\u00a0<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\" data-ccp-props=\"\">\u00a0<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\" data-contrast=\"none\">Organizations everywhere recognize that the ever-changing application environment is placing new demands on the IT infrastructure that supports them.\u00a0 Application workloads are deployed in a mix of virtualized and non-virtualized server and storage infrastructure, requiring the network infrastructure to provide consistent connectivity, security, and visibility across various bare metal, virtualized, and cloud computing environments: Applications The program instance is created dynamically.\u00a0 As a result, the provision, modification, and deletion of application network connections must also be dynamic.\u00a0 Business units require accelerated application deployment.\u00a0<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14px;\"> IT departments must provide a shared IT infrastructure to meet the time to market and increase return on investment (ROI) needs. As organizations deploy a mix of custom, open source, and off-the-shelf commercial applications, IT departments must manage security and quality of service (QoS) for environments that support multi-tenancy.\u00a0 Over time, applications have gradually transitioned to a monolithic, horizontally scalable multi-node model.\u00a0 The IT infrastructure supporting this model must scale with the speed of the business and support both 10 and 40 Gigabit Ethernet connections.\u00a0<\/span><\/p>","protected":false},"excerpt":{"rendered":"<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>N9K-C9372TX &#8211; Cisco Nexus 9000 Series Switch<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>Nexus 9300 with 48p 1\/10G-T and 6p 40G QSFP+<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>PDF Attachment:<\/p>\n<p><a href=\"https:\/\/gntme.com\/wp-content\/uploads\/2021\/04\/n9k-c9372tx-datasheet-converted.pdf\">n9k-c9372tx datasheet<\/a><\/p>","protected":false},"featured_media":53711,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[496],"product_tag":[],"class_list":{"0":"post-4264","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-switches-cisco-nexus-9000-series-cisco","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/4264","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=4264"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/53711"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=4264"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=4264"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=4264"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=4264"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}