{"id":4204,"date":"2025-09-29T10:43:34","date_gmt":"2025-09-29T10:43:34","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=4204"},"modified":"2025-09-29T10:43:34","modified_gmt":"2025-09-29T10:43:34","slug":"n3k-c3524p-10gx","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/n3k-c3524p-10gx\/","title":{"rendered":"N3K-C3524P-10GX"},"content":{"rendered":"<p>&nbsp;<\/p>\n<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"5\" valign=\"top\" width=\"100%\">\n<h2 align=\"center\"><strong><a href=\"https:\/\/itnetworks.ae\/n3k-c3524p-10gx.html\" target=\"_blank\" rel=\"noopener\">N3K-C3524P-10GX<\/a> Specification<\/strong><\/h2>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Physicalb <a href=\"https:\/\/gntme.com\/product\/n3k-c3524p-10gx\/\" target=\"_blank\" rel=\"noopener\">N3K-C3524P-10GX<\/a><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"84%\">\n<h4>\u25cf\u00a0\u00a024 fixed SFP+ ports (1 or 10 Gbps); expandable to 48 ports<\/h4>\n<p>\u25cf\u00a0\u00a0Dual redundant hot-swappable power supplies<\/p>\n<p>\u25cf\u00a0\u00a0Four individual redundant hot-swappable fans<\/p>\n<p>\u25cf\u00a0\u00a0One 1-PPS timing port, with the RF1.0\/2.3 QuickConnect connector type*<\/p>\n<p>\u25cf\u00a0\u00a0One 10\/100\/1000-Mbps management port<\/p>\n<p>\u25cf\u00a0\u00a0One RS-232 serial console port<\/p>\n<p>\u25cf\u00a0\u00a0Two USB ports<\/p>\n<p>\u25cf\u00a0\u00a0Locator LED<\/p>\n<p>\u25cf\u00a0\u00a0Locator LED button<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Performance<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"84%\">\u25cf\u00a0\u00a0480-Gbps switching capacity<\/p>\n<p>\u25cf\u00a0\u00a0Forwarding rate of 360 mpps<\/p>\n<p>\u25cf\u00a0\u00a0Line-rate traffic throughput (both Layer 2 and 3) on all ports<\/p>\n<p>\u25cf\u00a0\u00a0Configurable MTUs of up to 9216 bytes (jumbo frames)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Typical operating power<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"84%\">\u25cf\u00a0\u00a0102W<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Maximum power<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"84%\">\u25cf\u00a0\u00a0193W<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Typical heat dissipation<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"84%\">\u25cf\u00a0\u00a0348 BTUs per hr<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Maximum heat dissipation<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"84%\">\u25cf\u00a0\u00a0658 BTUs per hr<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" valign=\"top\">\n<p align=\"center\"><strong>Hardware Specifications N3K-C3524P-10GX<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">\n<p align=\"center\"><strong>Mode<\/strong><\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\">\n<p align=\"center\"><strong>Normal Mode<\/strong><\/p>\n<\/td>\n<td valign=\"top\">\n<p align=\"center\"><strong>Warp Mode<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"11\" valign=\"top\">Hardware tables and scalability<\/td>\n<td valign=\"top\">Number of MAC addresses<\/td>\n<td colspan=\"2\" valign=\"top\">64,000<\/td>\n<td valign=\"top\">8000<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of IPv4 unicast routes<\/td>\n<td colspan=\"2\" valign=\"top\">24,000<\/td>\n<td valign=\"top\">4000<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of IPv4 hosts<\/td>\n<td colspan=\"2\" valign=\"top\">64,000<\/td>\n<td valign=\"top\">8000<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of IPv4 multicast routes<\/td>\n<td colspan=\"2\" valign=\"top\">8000<\/td>\n<td valign=\"top\">8000<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of VLANS<\/td>\n<td colspan=\"3\" valign=\"top\">4096<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of ACL entries<\/td>\n<td colspan=\"3\" valign=\"top\">4096<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of spanning-tree instances<\/td>\n<td colspan=\"3\" valign=\"top\">Rapid Spanning Tree Protocol (RSTP): 512<\/p>\n<p>Multiple Spanning Tree (MST) Protocol: 64<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of EtherChannels<\/td>\n<td colspan=\"3\" valign=\"top\">24<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of ports per EtherChannel<\/td>\n<td colspan=\"3\" valign=\"top\">24<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Buffer size<\/td>\n<td colspan=\"3\" valign=\"top\">6 MB shared among 16 ports; 18 MB total<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Boot flash memory<\/td>\n<td colspan=\"3\" valign=\"top\">2 GB (3524P and 3548P models)<\/p>\n<p>4 GB (3524X and 3548X models)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" valign=\"top\">Power<\/td>\n<td valign=\"top\">Number of power supplies<\/td>\n<td colspan=\"3\" valign=\"top\">2 (redundant)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Power supply types<\/td>\n<td colspan=\"3\" valign=\"top\">\u25cf\u00a0\u00a0AC (forward and reversed airflow)<\/p>\n<p>\u25cf\u00a0\u00a0DC (forward\u00a0and reversed airflow)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Input voltage<\/td>\n<td colspan=\"3\" valign=\"top\">100 to 240 VAC<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Frequency<\/td>\n<td colspan=\"3\" valign=\"top\">50 to 60 Hz<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Power supply efficiency<\/td>\n<td colspan=\"3\" valign=\"top\">89 to 91% at 220V<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Cooling<\/td>\n<td colspan=\"4\" valign=\"top\">Forward and reversed airflow schemes<\/p>\n<p>\u25cf\u00a0\u00a0Forward airflow:Port-side exhaust (air enters through fan tray and power supplies and exits through ports)<\/p>\n<p>\u25cf\u00a0\u00a0Reversed airflow: Port-side intake (air enters through ports and exits through fan tray and power supplies)<\/p>\n<p>Four individual, hot-swappable fans (3+1 redundant)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\" valign=\"top\">Environment<\/td>\n<td valign=\"top\">Dimensions (height x width x depth)<\/td>\n<td colspan=\"3\" valign=\"top\">1.72 x 17.3 x 18.38 in. (4.36 x 43.9 x 46.7 cm)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Weight<\/td>\n<td colspan=\"3\" valign=\"top\">17.4 lb (7.9 kg)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Operating temperature<\/td>\n<td colspan=\"3\" valign=\"top\">32 to 104\u00b0 F (0 to 40\u00b0C)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Storage temperature<\/td>\n<td colspan=\"3\" valign=\"top\">-40 to 158\u00b0 F (-40 to 70\u00b0C)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Relative humidity (operating)<\/td>\n<td colspan=\"3\" valign=\"top\">\u25cf\u00a0\u00a010 to\u00a085% noncondensing<\/p>\n<p>\u25cf\u00a0\u00a0Up to 5 days at maximum (85%) humidity<\/p>\n<p>\u25cf\u00a0\u00a0Recommend ASHRAE\u00a0data center environment<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Relative humidity (nonoperating)<\/td>\n<td colspan=\"3\" valign=\"top\">5 to 95% noncondensing<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Altitude<\/td>\n<td colspan=\"3\" valign=\"top\">0 to 10,000 ft (0 to 3000m)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Mean time between failure (MTBF)<\/td>\n<td colspan=\"3\" valign=\"top\">317,030 hours<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" valign=\"top\">\n<p align=\"center\"><strong>Software Features N3K-C3524P-10GX<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Layer 2<\/td>\n<td colspan=\"4\" valign=\"top\">\u25cf\u00a0\u00a0Layer 2 switch ports and VLAN trunks<\/p>\n<p>\u25cf\u00a0\u00a0IEEE 802.1Q VLAN encapsulation<\/p>\n<p>\u25cf\u00a0\u00a0Support for up to 4096 VLANs<\/p>\n<p>\u25cf\u00a0\u00a0Rapid Per-VLAN Spanning Tree Plus (PVRST+) (IEEE 802.1w compatible)<\/p>\n<p>\u25cf\u00a0\u00a0MSTP (IEEE 802.1s): 64 instances<\/p>\n<p>\u25cf\u00a0\u00a0Spanning Tree PortFast<\/p>\n<p>\u25cf\u00a0\u00a0Spanning Tree Root Guard<\/p>\n<p>\u25cf\u00a0\u00a0Spanning Tree Bridge Assurance<\/p>\n<p>\u25cf\u00a0\u00a0Cisco EtherChannel technology (up to 24 ports per EtherChannel)<\/p>\n<p>\u25cf\u00a0\u00a0LACP: IEEE 802.3ad, IEEE 802.1ax<\/p>\n<p>\u25cf\u00a0\u00a0Advanced PortChannel hashing based on Layer 2, 3, and 4 information<\/p>\n<p>\u25cf\u00a0\u00a0Jumbo frames on all ports (up to 9216 bytes)<\/p>\n<p>\u25cf\u00a0\u00a0Storm control (multicast and broadcast)<\/p>\n<p>\u25cf\u00a0\u00a0Link-level flow control (IEEE 802.3x)<\/p>\n<p>\u25cf\u00a0\u00a0vPC<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Layer 3<\/td>\n<td colspan=\"4\" valign=\"top\">\u25cf\u00a0\u00a0Layer 3 interfaces: Routed ports on interfaces, switch virtual interfaces (SVIs), PortChannels, and subinterfaces (total:\u00a01024)<\/p>\n<p>\u25cf\u00a0\u00a024-way Equal-Cost Multipath (ECMP)<\/p>\n<p>\u25cf\u00a0\u00a04096 ACL entries<\/p>\n<p>\u25cf\u00a0\u00a0Routing protocols: Static, RIPv2, EIGRP, OSPF, and BGP<\/p>\n<p>\u25cf\u00a0\u00a0HSRP and VRRP<\/p>\n<p>\u25cf\u00a0\u00a0ACL: Routed ACL with Layer 3 and 4 options to match ingress and egress ACLs<\/p>\n<p>\u25cf\u00a0\u00a0VRF: VRF-Lite (IP VPN), VRF-aware unicast (BGP, OSPF, and RIP), and VRF\u2011aware multicast<\/p>\n<p>\u25cf\u00a0\u00a0VRF route leaking<\/p>\n<p>\u25cf\u00a0\u00a0Jumbo frame support (up to 9216 bytes)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Multicast<\/td>\n<td colspan=\"4\" valign=\"top\">\u25cf\u00a0\u00a0Multicast: PIMv2, PIM Sparse Mode (PIM-SM), SSM, and BiDir<\/p>\n<p>\u25cf\u00a0\u00a0Bootstrap router (BSR), Auto-RP, and Static RP<\/p>\n<p>\u25cf\u00a0\u00a0MSDP and Anycast RP<\/p>\n<p>\u25cf\u00a0\u00a0Internet Group Management Protocol (IGMP) Versions 2 and 3<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Security<\/td>\n<td colspan=\"4\" valign=\"top\">\u25cf\u00a0\u00a0Ingress ACLs (standard and extended) on Ethernet<\/p>\n<p>\u25cf\u00a0\u00a0Standard and extended Layer 3 to 4 ACLs include IPv4, Internet Control Message Protocol (ICMP), TCP, and User Datagram Protocol (UDP)<\/p>\n<p>\u25cf\u00a0\u00a0VLAN-based ACLs (VACLs)<\/p>\n<p>\u25cf\u00a0\u00a0Port-based ACLs (PACLs)<\/p>\n<p>\u25cf\u00a0\u00a0Named ACLs<\/p>\n<p>\u25cf\u00a0\u00a0ACLs on virtual terminals (VTYs)<\/p>\n<p>\u25cf\u00a0\u00a0Dynamic Host Configuration Protocol (DHCP) relay<\/p>\n<p>\u25cf\u00a0\u00a0Control Plane Policing (CoPP)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Cisco Nexus Data Broker<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/td>\n<td colspan=\"4\" valign=\"top\">\u25cf\u00a0\u00a0Topology support for tap and SPAN aggregation<\/p>\n<p>\u25cf\u00a0\u00a0Traffic load balancing to multiple monitoring tools<\/p>\n<p>\u25cf\u00a0\u00a0Time stamping using PTP<\/p>\n<p>\u25cf\u00a0\u00a0Packet truncation<\/p>\n<p>\u25cf\u00a0\u00a0Traffic filtering based on Layer 1 through Layer 4 header information<\/p>\n<p>\u25cf\u00a0\u00a0Traffic replication and forwarding to multiple monitoring tools<\/p>\n<p>\u25cf\u00a0\u00a0Robust RBAC<\/p>\n<p>\u25cf\u00a0\u00a0Northbound Representational State Transfer (REST) API for all programmability support<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Management<\/td>\n<td colspan=\"4\" valign=\"top\">\u25cf\u00a0\u00a0Power On Auto Provisioning (POAP)<\/p>\n<p>\u25cf\u00a0\u00a0Python scripting<\/p>\n<p>\u25cf\u00a0\u00a0Switch management using 10\/100\/1000-Mbps management or console ports<\/p>\n<p>\u25cf\u00a0\u00a0CLI-based console to provide detailed out-of-band management<\/p>\n<p>\u25cf\u00a0\u00a0In-band switch management<\/p>\n<p>\u25cf\u00a0\u00a0Locator and beacon LEDs<\/p>\n<p>\u25cf\u00a0\u00a0Configuration rollback<\/p>\n<p>\u25cf\u00a0\u00a0SSHv2<\/p>\n<p>\u25cf\u00a0\u00a0Telnet<\/p>\n<p>\u25cf\u00a0\u00a0AAA<\/p>\n<p>\u25cf\u00a0\u00a0AAA with RBAC<\/p>\n<p>\u25cf\u00a0\u00a0RADIUS<\/p>\n<p>\u25cf\u00a0\u00a0TACACS+<\/p>\n<p>\u25cf\u00a0\u00a0Syslog<\/p>\n<p>\u25cf\u00a0\u00a0Embedded packet analyzer<\/p>\n<p>\u25cf\u00a0\u00a0SNMP v1, v2, and v3<\/p>\n<p>\u25cf\u00a0\u00a0Enhanced SNMP MIB support<\/p>\n<p>\u25cf\u00a0\u00a0XML (NETCONF) support<\/p>\n<p>\u25cf\u00a0\u00a0Remote monitoring (RMON)<\/p>\n<p>\u25cf\u00a0\u00a0Advanced Encryption Standard (AES) for management traffic<\/p>\n<p>\u25cf\u00a0\u00a0Unified username and passwords across CLI and SNMP<\/p>\n<p>\u25cf\u00a0\u00a0Microsoft Challenge Handshake Authentication Protocol (MS-CHAP)<\/p>\n<p>\u25cf\u00a0\u00a0Digital certificates for management between switch and RADIUS server<\/p>\n<p>\u25cf\u00a0\u00a0Cisco Discovery Protocol Versions 1 and 2<\/p>\n<p>\u25cf\u00a0\u00a0RBAC<\/p>\n<p>\u25cf\u00a0\u00a0SPAN on physical, PortChannel, and VLAN<\/p>\n<p>\u25cf\u00a0\u00a0ERSPAN Versions 2 and 3<\/p>\n<p>\u25cf\u00a0\u00a0Ingress and egress packet counters per interface<\/p>\n<p>\u25cf\u00a0\u00a0Network Time Protocol (NTP)<\/p>\n<p>\u25cf\u00a0\u00a0Cisco OHMS<\/p>\n<p>\u25cf\u00a0\u00a0Comprehensive bootup diagnostic tests<\/p>\n<p>\u25cf\u00a0\u00a0Cisco Call Home<\/p>\n<p>\u25cf\u00a0\u00a0Cisco DCNM<\/p>\n<p>\u25cf\u00a0\u00a0Active buffer monitoring<\/p>\n<p>\u25cf\u00a0\u00a0PTP (IEEE 1588) boundary clock<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" valign=\"top\">\n<p align=\"center\"><strong>Management and Standards Support N3K-C3524P-10GX<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">MIB support<\/td>\n<td colspan=\"2\" valign=\"top\">Generic MIBs<\/p>\n<p>\u25cf\u00a0\u00a0SNMPv2-SMI<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-SMI<\/p>\n<p>\u25cf\u00a0\u00a0SNMPv2-TM<\/p>\n<p>\u25cf\u00a0\u00a0SNMPv2-TC<\/p>\n<p>\u25cf\u00a0\u00a0IANA-ADDRESS-FAMILY-NUMBERS-MIB<\/p>\n<p>\u25cf\u00a0\u00a0IANAifType-MIB<\/p>\n<p>\u25cf\u00a0\u00a0IANAiprouteprotocol-MIB<\/p>\n<p>\u25cf\u00a0\u00a0HCNUM-TC<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-TC<\/p>\n<p>\u25cf\u00a0\u00a0SNMPv2-MIB<\/p>\n<p>\u25cf\u00a0\u00a0SNMP-COMMUNITY-MIB<\/p>\n<p>\u25cf\u00a0\u00a0SNMP-FRAMEWORK-MIB<\/p>\n<p>\u25cf\u00a0\u00a0SNMP-NOTIFICATION-MIB<\/p>\n<p>\u25cf\u00a0\u00a0SNMP-TARGET-MIB<\/p>\n<p>\u25cf\u00a0\u00a0SNMP-USER-BASED-SM-MIB<\/p>\n<p>\u25cf\u00a0\u00a0SNMP-VIEW-BASED-ACM-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-SNMP-VACM-EXT-MIB<\/p>\n<p>Ethernet MIBs<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-VLAN-MEMBERSHIP-MIB<\/p>\n<p>Configuration MIBs<\/p>\n<p>\u25cf\u00a0\u00a0ENTITY-MIB<\/p>\n<p>\u25cf\u00a0\u00a0IF-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-ENTITY-EXT-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-ENTITY-FRU-CONTROL-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-ENTITY-SENSOR-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-SYSTEM-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-SYSTEM-EXT-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-IP-IF-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-IF-EXTENSION-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-NTP-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-IMAGE-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-IMAGE-UPGRADE-MIB<\/td>\n<td colspan=\"2\" valign=\"top\">Monitoring MIBs<\/p>\n<p>\u25cf\u00a0\u00a0NOTIFICATION-LOG-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-SYSLOG-EXT-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-PROCESS-MIB<\/p>\n<p>\u25cf\u00a0\u00a0RMON-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-RMON-CONFIG-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-HC-ALARM-MIB<\/p>\n<p>Security MIBs<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-AAA-SERVER-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-AAA-SERVER-EXT-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-COMMON-ROLES-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-COMMON-MGMT-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-SECURE-SHELL-MIB<\/p>\n<p>Miscellaneous MIBs<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-LICENSE-MGR-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-FEATURE-CONTROL-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-CDP-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-RF-MIB<\/p>\n<p>Layer 3 and Routing MIBs<\/p>\n<p>\u25cf\u00a0\u00a0UDP-MIB<\/p>\n<p>\u25cf\u00a0\u00a0TCP-MIB<\/p>\n<p>\u25cf\u00a0\u00a0OSPF-MIB<\/p>\n<p>\u25cf\u00a0\u00a0OSPF-TRAP-MIB<\/p>\n<p>\u25cf\u00a0\u00a0BGP4-MIB<\/p>\n<p>\u25cf\u00a0\u00a0CISCO-HSRP-MIB<\/p>\n<p>\u25cf\u00a0\u00a0PIM-MIB<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Standards<\/td>\n<td colspan=\"4\" valign=\"top\">\u25cf\u00a0\u00a0IEEE 802.1D: Spanning Tree Protocol<\/p>\n<p>\u25cf\u00a0\u00a0IEEE 802.1p: CoS Prioritization<\/p>\n<p>\u25cf\u00a0\u00a0IEEE 802.1Q: VLAN Tagging<\/p>\n<p>\u25cf\u00a0\u00a0IEEE 802.1s: Multiple VLAN Instances of Spanning Tree Protocol<\/p>\n<p>\u25cf\u00a0\u00a0IEEE 802.1w: Rapid Reconfiguration of Spanning Tree Protocol<\/p>\n<p>\u25cf\u00a0\u00a0IEEE 802.3z: Gigabit Ethernet<\/p>\n<p>\u25cf\u00a0\u00a0IEEE 802.3ad: Link Aggregation Control Protocol (LACP)<\/p>\n<p>\u25cf\u00a0\u00a0IEEE 802.1ax: Link Aggregation Control Protocol (LACP)<\/p>\n<p>\u25cf\u00a0\u00a0IEEE 802.3ae: 10 Gigabit Ethernet<\/p>\n<p>\u25cf\u00a0\u00a0IEEE 802.3ba: 40 Gigabit Ethernet<\/p>\n<p>\u25cf\u00a0\u00a0IEEE 802.1ab: LLDP<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">RFC<\/td>\n<td colspan=\"4\" valign=\"top\">BGP<\/p>\n<p>\u25cf\u00a0\u00a0RFC 1997: BGP CommunitiesAttribute<\/p>\n<p>\u25cf\u00a0\u00a0RFC 2385: Protection of BGP Sessions with the TCP MD5 Signature Option<\/p>\n<p>\u25cf\u00a0\u00a0RFC 2439: BGP Route Flap Damping<\/p>\n<p>\u25cf\u00a0\u00a0RFC 2519: A Framework for Inter-Domain Route Aggregation<\/p>\n<p>\u25cf\u00a0\u00a0RFC 2545: Use of BGPv4 Multiprotocol Extensions<\/p>\n<p>\u25cf\u00a0\u00a0RFC 2858: Multiprotocol Extensions for BGPv4<\/p>\n<p>\u25cf\u00a0\u00a0RFC 3065: Autonomous System Confederations for BGP<\/p>\n<p>\u25cf\u00a0\u00a0RFC 3392: Capabilities Advertisement with BGPv4<\/p>\n<p>\u25cf\u00a0\u00a0RFC 4271: BGPv4<\/p>\n<p>\u25cf\u00a0\u00a0RFC 4273: BGPv4 MIB: Definitions of Managed Objects for BGPv4<\/p>\n<p>\u25cf\u00a0\u00a0RFC 4456: BGP Route Reflection<\/p>\n<p>\u25cf\u00a0\u00a0RFC 4486: Subcodes for BGP Cease Notification Message<\/p>\n<p>\u25cf\u00a0\u00a0RFC 4724: Graceful Restart Mechanism for BGP<\/p>\n<p>\u25cf\u00a0\u00a0RFC 4893: BGP Support for Four-Octet AS Number Space<\/p>\n<p>OSPF<\/p>\n<p>\u25cf\u00a0\u00a0RFC 2328: OSPFVersion 2<\/p>\n<p>\u25cf\u00a0\u00a08431RFC 3101: OSPF Not-So-Stubby-Area (NSSA) Option<\/p>\n<p>\u25cf\u00a0\u00a0RFC 3137: OSPF Stub Router Advertisement<\/p>\n<p>\u25cf\u00a0\u00a0RFC 3509: Alternative Implementations of OSPF Area Border Routers<\/p>\n<p>\u25cf\u00a0\u00a0RFC 3623: Graceful OSPF Restart<\/p>\n<p>\u25cf\u00a0\u00a0RFC 4750: OSPF Version\u00a02 MIB<\/p>\n<p>RIP<\/p>\n<p>\u25cf\u00a0\u00a0RFC1724: RIPv2 MIB Extension<\/p>\n<p>\u25cf\u00a0\u00a0RFC 2082: RIPv2 MD5 Authentication<\/p>\n<p>\u25cf\u00a0\u00a0RFC 2453: RIP Version 2<\/p>\n<p>\u25cf\u00a0\u00a0IP Services<\/p>\n<p>\u25cf\u00a0\u00a0RFC 768: User Datagram Protocol (UDP)<\/p>\n<p>\u25cf\u00a0\u00a0RFC 783:\u00a0Trivial File Transfer Protocol (TFTP)<\/p>\n<p>\u25cf\u00a0\u00a0RFC 791: IP<\/p>\n<p>\u25cf\u00a0\u00a0RFC 792: Internet Control Message Protocol (ICMP)<\/p>\n<p>\u25cf\u00a0\u00a0RFC 793: TCP<\/p>\n<p>\u25cf\u00a0\u00a0RFC 826: ARP<\/p>\n<p>\u25cf\u00a0\u00a0RFC 854: Telnet<\/p>\n<p>\u25cf\u00a0\u00a0RFC 959: FTP<\/p>\n<p>\u25cf\u00a0\u00a0RFC 1027: Proxy ARP<\/p>\n<p>\u25cf\u00a0\u00a0RFC 1305: Network Time Protocol (NTP) Version 3<\/p>\n<p>\u25cf\u00a0\u00a0RFC 1519: Classless Interdomain Routing (CIDR)<\/p>\n<p>\u25cf\u00a0\u00a0RFC 1542: BootP Relay<\/p>\n<p>\u25cf\u00a0\u00a0RFC 1591: Domain Name System (DNS) Client<\/p>\n<p>\u25cf\u00a0\u00a0RFC 1812: IPv4 Routers<\/p>\n<p>\u25cf\u00a0\u00a0RFC 2131: DHCP Helper<\/p>\n<p>\u25cf\u00a0\u00a0RFC 2338: VRRP<\/p>\n<p>IP Multicast<\/p>\n<p>\u25cf\u00a0\u00a0RFC 2236: InternetGroup Management Protocol, version 2<\/p>\n<p>\u25cf\u00a0\u00a0RFC 3376: Internet Group Management Protocol, Version 3<\/p>\n<p>\u25cf\u00a0\u00a0RFC 3446: Anycast Rendezvous Point Mechanism Using PIM and MSDP<\/p>\n<p>\u25cf\u00a0\u00a0RFC 3569: An Overview of SSM<\/p>\n<p>\u25cf\u00a0\u00a0RFC 3618: Multicast Source Discovery Protocol (MSDP)<\/p>\n<p>\u25cf\u00a0\u00a0RFC 4601: Protocol Independent Multicast &#8211; Sparse Mode (PIM-SM): Protocol Specification (Revised)<\/p>\n<p>\u25cf\u00a0\u00a0RFC 4607: Source-Specific Multicast for IP<\/p>\n<p>\u25cf\u00a0\u00a0RFC 4610: Anycast-RP using PIM<\/p>\n<p>\u25cf\u00a0\u00a0RFC 5015: PIM BiDir<\/p>\n<p>\u25cf\u00a0\u00a0RFC 5132: IP Multicast\u00a0MIB<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>\n<h1><span style=\"font-size: 14px;\">Cisco N3K-C3524P-10GX Nexus 3500 Series Switch<\/span><\/h1>\n<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>\n<h3><span style=\"font-size: 14px;\">Cisco Nexus N3K-C3524P-10GX Switch Layer 2 and layer 3 &#8211; 24 x 10G SFP+ active Ethernet ports &#8211; Ultra-Low latency &#8211; Managed<\/span><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":53652,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[479],"product_tag":[],"class_list":{"0":"post-4204","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-switches-cisco-switch-catalyst-3850-cisco","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/4204","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=4204"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/53652"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=4204"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=4204"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=4204"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=4204"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}