{"id":4203,"date":"2025-09-29T10:43:32","date_gmt":"2025-09-29T10:43:32","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=4203"},"modified":"2025-09-29T10:43:34","modified_gmt":"2025-09-29T10:43:34","slug":"ws-c296048tc-s","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/ws-c296048tc-s\/","title":{"rendered":"WS-C2960+48TC-S"},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<h3><strong>WS-C2960+48TC-S Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Configurations<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10\/100 Ethernet Interfaces<\/p>\n<\/td>\n<td>\n<p>48<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Uplink Interfaces<\/p>\n<\/td>\n<td>\n<p>2 (SFP or 1000BASE-T)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Cisco IOS Software Feature Set<\/p>\n<\/td>\n<td>\n<p>LAN Lite<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Available PoE Power<\/p>\n<\/td>\n<td>\n<p>None<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Hardware<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Flash memory<\/p>\n<\/td>\n<td>\n<p>64 MB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DRAM<\/p>\n<\/td>\n<td>\n<p>128 MB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Performance and Scalability<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Forwarding bandwidth<\/p>\n<\/td>\n<td>\n<p>16 Gbps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum active VLANs<\/p>\n<\/td>\n<td>\n<p>64<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>VLAN IDs available<\/p>\n<\/td>\n<td>\n<p>4K<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum transmission unit (MTU) &#8211; L3 packet<\/p>\n<\/td>\n<td>\n<p>9000 bytes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Jumbo frame &#8211; Ethernet frame<\/p>\n<\/td>\n<td>\n<p>9018 bytes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Forwarding Rate: 64-Byte L3 Packets, Millions of packets per second<\/p>\n<\/td>\n<td>\n<p>10.1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Mechanical <\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Dimensions (H x W x D)<\/p>\n<\/td>\n<td>\n<p><span>1.73 x 17.70 x 9.52<\/span>&nbsp;in (<span>4.4 x 45.0 x 24.2<\/span> cm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Weight<\/p>\n<\/td>\n<td>\n<p>8 lb (3.6 Kg)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Package Weight<\/p>\n<\/td>\n<td>\n<p>17.64 lb (8.0 Kg)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Environmental Ranges<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating temperature up to 5000 ft (1500 m)<\/p>\n<\/td>\n<td>\n<p>23&ordm; to 113&ordm;F<\/p>\n<p>(-5&ordm; to 45&ordm;C)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating temperature up to 10,000 ft (3000 m)<\/p>\n<\/td>\n<td>\n<p>23&ordm; to 104&ordm;F<\/p>\n<p>(-5&ordm; to 40&ordm;C)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Short-term exception at sea level*<\/p>\n<\/td>\n<td>\n<p>23&ordm; to 131&ordm;F<\/p>\n<p>(-5&ordm; to 55&ordm;C)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Short-term exception up to 5000 feet (1500 m)*<\/p>\n<\/td>\n<td>\n<p>23&ordm; to 122&ordm;F<\/p>\n<p>(-5&ordm; to 50&ordm;C)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Short-term exception up to 10,000 feet (3000 m)*<\/p>\n<\/td>\n<td>\n<p>23&ordm; to 113&ordm;F<\/p>\n<p>(-5&ordm; to 45&ordm;C)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Short-term exception up to 13,000 feet (4000 m)*<\/p>\n<\/td>\n<td>\n<p>23&ordm; to 104&ordm;F<\/p>\n<p>(-5&ordm; to 40&ordm;C)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Storage temperature up to 15,000 feet (4573 m)<\/p>\n<\/td>\n<td>\n<p>23&ordm; to 158&ordm;F<\/p>\n<p>(-25&ordm; to 70&ordm;C)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating altitude<\/p>\n<\/td>\n<td>\n<p>Up to 10,000 Feet<\/p>\n<p>(Up to 3,000 Meters)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Storage altitude<\/p>\n<\/td>\n<td>\n<p>Up to 13,000 Feet<\/p>\n<p>(Up to 4,000 Meters)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating relative humidity<\/p>\n<\/td>\n<td>\n<p>10% to 95% noncondensing<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Storage relative humidity<\/p>\n<\/td>\n<td>\n<p>10% to 95% noncondensing<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Sound Pressure, dBA<\/p>\n<\/td>\n<td>\n<p>Typical, LpAm: 33<\/p>\n<p>Maximum, LpAD: 36<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Sound Power, dbA<\/p>\n<\/td>\n<td>\n<p>Typical, LwA: 43<\/p>\n<p>Maximum, LwAD: 46<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>MTBF in thousands of hours<\/p>\n<\/td>\n<td>\n<p>623<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Connectors and Interfaces<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Ethernet Interfaces<\/p>\n<\/td>\n<td>\n<ul>\n<li>10BASE-T ports: RJ-45 connectors, 2-pair Category 3, 4, or 5 unshielded twisted-pair (UTP) cabling<\/li>\n<li>100BASE-TX ports: RJ-45 connectors, 2-pair Category 5 UTP cabling<\/li>\n<li>1000BASE-T ports: RJ-45 connectors, 4-pair Category 5 UTP cabling<\/li>\n<li>1000BASE-T SFP-based ports: RJ-45 connectors, 4-pair Category 5 UTP cabling<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Indicator LEDs<\/p>\n<\/td>\n<td>\n<ul>\n<li>Per-port status: Link integrity, disabled, activity, speed, and full duplex<\/li>\n<li>System status, Port Status, RPS, link duplex, and link speed<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Console<\/p>\n<\/td>\n<td>\n<p>Cisco Catalyst console cables:<\/p>\n<ul>\n<li>CAB-CONSOLE-RJ45 Console cable 6 ft. with RJ-45<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Power<\/p>\n<\/td>\n<td>\n<ul>\n<li>The internal power supply is an auto-ranging unit and supports input voltages between 100 and 240V AC.<\/li>\n<li>Use the supplied AC power cord to connect the AC power connector to an AC power outlet.<\/li>\n<li>The Cisco RPS connector offers connection for an optional Cisco RPS 2300 that uses AC input and supplies DC output to the switch.<\/li>\n<li>Only the Cisco RPS 2300 (model PWR-RPS2300) should be attached to the redundant-power-system receptacle.<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Management and Standards Support<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Management<\/p>\n<\/td>\n<td>\n<ul>\n<li>BRIDGE-MIB<\/li>\n<li>CISCO-CABLE-DIAG-MIB<\/li>\n<li>CISCO-CDP-MIB<\/li>\n<li>CISCO-CLUSTER-MIB<\/li>\n<li>CISCO-CONFIG-COPY-MIB<\/li>\n<li>CISCO-CONFIG-MAN-MIB<\/li>\n<li>CISCO-DHCP-SNOOPING-MIB<\/li>\n<li>CISCO-ENTITY-VENDORTYPE-OID-MIB<\/li>\n<li>CISCO-ENVMON-MIB<\/li>\n<li>CISCO-ERR-DISABLE-MIB<\/li>\n<li>CISCO-FLASH-MIB<\/li>\n<li>CISCO-FTP-CLIENT-MIB<\/li>\n<li>CISCO-IGMP-FILTER-MIB<\/li>\n<li>CISCO-IMAGE-MIB<\/li>\n<li>CISCO-IP-STAT-MIB<\/li>\n<li>CISCO-LAG-MIB<\/li>\n<li>CISCO-MAC-NOTIFICATION-MIB<\/li>\n<li>CISCO-MEMORY-POOL-MIB<\/li>\n<li>CISCO-PAGP-MIB<\/li>\n<li>CISCO-PING-MIB<\/li>\n<li>CISCO-POE-EXTENSIONS-MIB<\/li>\n<li>CISCO-PORT-QOS-MIB<\/li>\n<li>CISCO-PORT-SECURITY-MIB<\/li>\n<li>CISCO-PORT-STORM-CONTROL-MIB<\/li>\n<li>CISCO-PRODUCTS-MIB<\/li>\n<li>CISCO-PROCESS-MIB<\/li>\n<li>CISCO-RTTMON-MIB<\/li>\n<li>CISCO-SMI-MIB<\/li>\n<li>CISCO-STP-EXTENSIONS-MIB<\/li>\n<li>CISCO-SYSLOG-MIB<\/li>\n<li>CISCO-TC-MIB<\/li>\n<li>CICSO-TCP-MIB<\/li>\n<li>CISCO-UDLDP-MIB<\/li>\n<li>CISCO-VLAN-IFTABLE<\/li>\n<li>RELATIONSHIP-MIB<\/li>\n<li>CISCO-VLAN-MEMBERSHIP-MIB<\/li>\n<li>CISCO-VTP-MIB<\/li>\n<li>ENTITY-MIB<\/li>\n<li>ETHERLIKE-MIB<\/li>\n<li>IEEE8021-PAE-MIB<\/li>\n<li>IEEE8023-LAG-MIB<\/li>\n<li>IF-MIB<\/li>\n<li>INET-ADDRESS-MIB<\/li>\n<li>OLD-CISCO-CHASSIS-MIB<\/li>\n<li>OLD-CISCO-FLASH-MIB<\/li>\n<li>OLD-CISCO-INTERFACES-MIB<\/li>\n<li>OLD-CISCO-IP-MIB<\/li>\n<li>OLD-CISCO-SYS-MIB<\/li>\n<li>OLD-CISCO-TCP-MIB<\/li>\n<li>OLD-CISCO-TS-MIB<\/li>\n<li>RFC1213-MIB<\/li>\n<li>RMON-MIB<\/li>\n<li>RMON2-MIB<\/li>\n<li>SNMP-FRAMEWORK-MIB<\/li>\n<li>SNMP-MPD-MIB<\/li>\n<li>SNMP-NOTIFICATION-MIB<\/li>\n<li>SNMP-TARGET-MIB<\/li>\n<li>SNMPv2-MIB<\/li>\n<li>TCP-MIB<\/li>\n<li>UDP-MIB<\/li>\n<li>ePM MIB<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Standards<\/p>\n<\/td>\n<td>\n<ul>\n<li>IEEE 802.1D Spanning Tree Protocol<\/li>\n<li>IEEE 802.1p CoS Prioritization<\/li>\n<li>IEEE 802.1Q VLAN<\/li>\n<li>IEEE 802.1s<\/li>\n<li>IEEE 802.1w<\/li>\n<li>IEEE 802.1X<\/li>\n<li>IEEE 802.1ab (LLDP)<\/li>\n<li>IEEE 802.3ad<\/li>\n<li>IEEE 802.3af<\/li>\n<li>IEEE 802.3ah (100BASE-X single\/multimode fiber only)<\/li>\n<li>IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports<\/li>\n<li>IEEE 802.3 10BASE-T<\/li>\n<li>IEEE 802.3u 100BASE-TX<\/li>\n<li>IEEE 802.3ab 1000BASE-T<\/li>\n<li>IEEE 802.3z 1000BASE-X<\/li>\n<li>RMON I and II standards<\/li>\n<li>SNMP v1, v2c, and v3<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RFC compliance<\/p>\n<\/td>\n<td>\n<ul>\n<li>RFC 768 &#8211; UDP<\/li>\n<li>RFC 783 &#8211; TFTP<\/li>\n<li>RFC 791 &#8211; IP<\/li>\n<li>RFC 792 &#8211; ICMP<\/li>\n<li>RFC 793 &#8211; TCP<\/li>\n<li>RFC 826 &#8211; ARP<\/li>\n<li>RFC 854 &#8211; Telnet<\/li>\n<li>RFC 951 &#8211; Bootstrap Protocol (BOOTP)<\/li>\n<li>RFC 959 &#8211; FTP<\/li>\n<li>RFC 1112 &#8211; IP Multicast and IGMP<\/li>\n<li>RFC 1157 &#8211; SNMP v1<\/li>\n<li>RFC 1166 &#8211; IP Addresses<\/li>\n<li>RFC 1256 &#8211; Internet Control Message Protocol (ICMP) Router Discovery<\/li>\n<li>RFC 1305 &#8211; NTP<\/li>\n<li>RFC 1492 &#8211; TACACS+<\/li>\n<li>RFC 1493 &#8211; Bridge MIB<\/li>\n<li>RFC 1542 &#8211; BOOTP extensions<\/li>\n<li>RFC 1643 &#8211; Ethernet Interface MIB<\/li>\n<li>RFC 1757 &#8211; RMON<\/li>\n<li>RFC 1901 &#8211; SNMP v2C<\/li>\n<li>RFC 1902-1907 &#8211; SNMP v2<\/li>\n<li>RFC 1981 &#8211; Path MTU Discovery for IPv6<\/li>\n<li>FRC 2068 &#8211; HTTP<\/li>\n<li>RFC 2131 &#8211; DHCP<\/li>\n<li>RFC 2138 &#8211; RADIUS<\/li>\n<li>RFC 2233 &#8211; IF MIB v3<\/li>\n<li>RFC 2373 &#8211; IPv6 Aggregatable Addrs<\/li>\n<li>RFC 2460 &#8211; IPv6<\/li>\n<li>RFC 2461 &#8211; IPv6 Neighbor Discovery<\/li>\n<li>RFC 2462 &#8211; IPv6 Autoconfiguration<\/li>\n<li>RFC 2463 &#8211; ICMP IPv6<\/li>\n<li>RFC 2474 &#8211; Differentiated Services (DiffServ) Precedence<\/li>\n<li>RFC 2597 &#8211; Assured Forwarding<\/li>\n<li>RFC 2598 &#8211; Expedited Forwarding<\/li>\n<li>RFC 2571 &#8211; SNMP Management<\/li>\n<li>RFC 3046 &#8211; DHCP Relay Agent Information Option<\/li>\n<li>RFC 3376 &#8211; IGMP v3<\/li>\n<li>RFC 3580 &#8211; 802.1X RADIUS<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Voltage and Power Ratings<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Voltage (Autoranging)<\/p>\n<\/td>\n<td>\n<p>100 to 240 VAC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Current (Amperes)<\/p>\n<\/td>\n<td>\n<p>0.6 &#8211; 0.3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Frequency<\/p>\n<\/td>\n<td>\n<p>50 to 60Hz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Power Rating (kVA)<\/p>\n<\/td>\n<td>\n<p>0.04<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DC Input Voltages (RPS Input)<\/p>\n<\/td>\n<td>\n<p>3A at 12V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Power Consumption<\/p>\n<\/td>\n<td>\n<p>0% traffic: 29.9<\/p>\n<p>10% traffic: 29.7<\/p>\n<p>100% traffic: 30.2<\/p>\n<p>ATIS weighted average: 29.8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Safety and Compliance<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Regulatory Compliance<\/p>\n<\/td>\n<td>\n<p>Products should comply with CE Marking per directives 2004\/108\/EC and 2006\/95\/EC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Safety<\/p>\n<\/td>\n<td>\n<p>UL 60950-1 Second Edition<\/p>\n<p>CAN\/CSA-C22.2 No. 60950-1 Second Edition<\/p>\n<p>EN 60950-1 Second Edition<\/p>\n<p>IEC 60950-1 Second Edition<\/p>\n<p>AS\/NZS 60950-1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>EMC &#8211; Emissions<\/p>\n<\/td>\n<td>\n<p>47CFR Part 15 (CFR 47) Class A<\/p>\n<p>AS\/NZS CISPR22 Class A<\/p>\n<p>CISPR22 Class A<\/p>\n<p>EN55022 Class A<\/p>\n<p>ICES003 Class A<\/p>\n<p>VCCI Class A<\/p>\n<p>EN61000-3-2<\/p>\n<p>EN61000-3-3<\/p>\n<p>KN22 Class A<\/p>\n<p>CNS13438 Class A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>EMC &#8211; Immunity<\/p>\n<\/td>\n<td>\n<p>EN55024<\/p>\n<p>CISPR24<\/p>\n<p>EN300386<\/p>\n<p>KN24<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Environmental<\/p>\n<\/td>\n<td>\n<p>Reduction of Hazardous Substances (RoHS) including Directive 2011\/65\/EU<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<table>< tbody > <\/p>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>WS-C2960+48TC-S Catalyst 2960 Plus Switch<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td itemprop=\"description\">Catalyst 2960 Plus 48 10\/100 + 2 T\/SFP LAN Lite<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":53645,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[488],"product_tag":[],"class_list":{"0":"post-4203","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-switches-cisco-switch-catalyst-2960-cisco","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/4203","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=4203"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/53645"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=4203"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=4203"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=4203"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=4203"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}