{"id":36705,"date":"2025-09-29T14:59:35","date_gmt":"2025-09-29T14:59:35","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=36705"},"modified":"2025-09-29T14:59:36","modified_gmt":"2025-09-29T14:59:36","slug":"tnns0vbswf15","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/tnns0vbswf15\/","title":{"rendered":"TNNS0VBSWF15"},"content":{"rendered":"<table border=\"1\" cellpadding=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td colspan=\"5\" valign=\"top\" width=\"568\">\n<h3 align=\"center\"><strong>TNNS0VBSWF1<\/strong><strong>5<\/strong><strong>&nbsp;Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\">\n<p><strong>Part Number<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">\n<p>88032XCR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\">\n<p><strong>Model<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">\n<p>TNNS0VBSWF15<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\">\n<p><strong>Description<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">\n<p>OptiX OSN 7500 II-Basic Software Package,V200R015(Per Subrack)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\">\n<p><strong>Discount Category<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">\n<p>Basic Software<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\">\n<p><strong>Product Line<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">\n<p>Networking<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\">\n<p><strong>Sub Product Family<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">\n<p>MSTP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\">\n<p><strong>Product Series<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">\n<p>OSN 7500 II<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\">\n<p><strong>UOM<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">\n<p>PCS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" valign=\"top\" width=\"568\">\n<p align=\"center\"><strong>Huawei OSN 7500 II<\/strong><strong>&nbsp;<\/strong><strong>Specification<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\">\n<p><strong>Dimensions<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">\n<p>800mm (H) x 496mm (W) x 295mm (D)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\">\n<p><strong>Switch Capacity<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">\n<p>Packet: 320 Gbit\/s and TDM: 360 Gbit\/s (higher order), 40 Gbit\/s (lower order), OTN: 560Gbit\/s<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\">\n<p><strong>Service Slots<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">\n<p>32 slots, 16 slots for interface boards and 16 slots for processing boards with same bandwidth per slot<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"9\" valign=\"top\" width=\"147\">\n<p><strong>Supported Interface<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>OTN interface<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>OTU-1, OTU-2\/2e, OTU-3(40G, compliant with OTL3.4 standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>Ethernet interface<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>FE\/GE\/10GE\/40GE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>SDH interface<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>STM-1\/4\/16\/64<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>PDH interface<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>E1\/T1, E3\/T3, E4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>ATM interface<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>E1, STM-1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>WDM interface<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>40 DWDM wavelengths, compliant with ITU-T G.694.1<\/p>\n<p>8 CWDM wavelengths, compliant with ITU-T G.694.2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>SAN interface<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>FDDI, ESCON, FICON\/FICON Express, FC100\/200\/400\/800\/1200<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>PCM interface<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>FXS\/FXO, 2\/4W VF &amp; E&amp;M<\/p>\n<p>X.21\/V.35\/V.11\/V.24\/V.28, RS232\/RS422, RS449\/RS423A\/RS422A, RS530\/RS530A,RS485, G.703 64 kbit\/s codirectional<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>Other interface<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>DDN, Video<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\">\n<p><strong>Networking Mode<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">\n<p>Supports packet, hybrid (packet + SDH or OTN + SDH) or SDH networking<\/p>\n<p>Supporting WDM networking<\/p>\n<p>Supporting single-fiber bidirectional transmission<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\">\n<p><strong>Power Supply<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">\n<p>-48V DC\/-60V DC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" valign=\"top\" width=\"147\">\n<p><strong>Operation<\/strong><strong><\/strong><\/p>\n<p><strong>Environment<\/strong><strong><\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"140\">\n<p>&nbsp;<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"140\">\n<p>Temperature<\/p>\n<\/td>\n<td valign=\"top\" width=\"140\">\n<p>Relative Humidity<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"140\">\n<p>Long term<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"140\">\n<p>0<span style=\"font-family: \u00e5\u00ae\u2039\u00e4\u00bd\u201c;\">&ordm;<\/span><span style=\"font-family: Calibri;\">C ~ 45<\/span><span style=\"font-family: \u00e5\u00ae\u2039\u00e4\u00bd\u201c;\">&ordm;<\/span><span style=\"font-family: Calibri;\">C<\/span><\/p>\n<\/td>\n<td valign=\"top\" width=\"140\">\n<p>5% ~ 85%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"140\">\n<p>Short term<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"140\">\n<p>-5<span style=\"font-family: \u00e5\u00ae\u2039\u00e4\u00bd\u201c;\">&ordm;<\/span><span style=\"font-family: Calibri;\">C ~ 55<\/span><span style=\"font-family: \u00e5\u00ae\u2039\u00e4\u00bd\u201c;\">&ordm;<\/span><span style=\"font-family: Calibri;\">C<\/span><\/p>\n<\/td>\n<td valign=\"top\" width=\"140\">\n<p>5% ~ 95%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\">\n<p><strong>Ethernet Feature<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">\n<p>E-Line and E-LAN, QinQ<\/p>\n<p>MPLS-TP based VPWS and VPLS<\/p>\n<p>Multi-section pseudo-wire (MS-PW)<\/p>\n<p>ETH PWE3, TDM PWE3, A TM\/IMA PWE3<\/p>\n<p>IGMP Snooping V2<\/p>\n<p>Blacklist, Broadcast packet suppression, ACL<\/p>\n<p>VLAN SWAP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\">\n<p><strong>PCM Feature<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">\n<p>Voice or data Conference\/Meeting,P2MP,MP2MP<\/p>\n<p>FXO\/FXS mode can be set by software<\/p>\n<p>E&amp;M Interface voltage can be set by software (-48V\/-12V)<\/p>\n<p>E&amp;M signaling can be set by software (Bell types I, II, III, IV, V and British Telecom SSDC5)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\">\n<p><strong>QoS<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">\n<p>Hierarchical QoS scheduling and traffic shaping<\/p>\n<p>DiffServ mode based on traffic classification, eight priority queues<\/p>\n<p>Simple traffic classification, complex traffic classification, per hop behavior (PHB),and A CL<\/p>\n<p>Committed access rate (CAR), shaping based on port scheduling priority<\/p>\n<p>PQ scheduling priority, weighted fair queuing (WFQ) and PQ+WFQ queuing<\/p>\n<p>Tail drop and weighted random early detection (WRED)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" valign=\"top\" width=\"147\">\n<p><strong>OAM<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>MPLS-TP OAM<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>LSP\/PW OAM:<\/p>\n<p>CC, LB, LT<\/p>\n<p>AIS, RDI<\/p>\n<p>LM, DM<\/p>\n<p>LCK, TST<\/p>\n<p>CSF<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>MPLS OAM<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>LSP\/PW OAM: FDI, BDI,CV, FFD, TraceRoute, Ping, LM, DM<\/p>\n<p>PW OAM: CES PW VCCV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>Ethernet OAM<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>ETH-CC, ETH-Loopback, ETH-Link Trace, Remote Loopback, Remote Fault Detection, RMON(RFC 2819)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" valign=\"top\" width=\"147\">\n<p><strong>Protection<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>Equipment-level Protection<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>Universal Cross-Connect, System Control and Clock Processing Board 1+1 backup and power 1+1 backup<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>MPLS-TP based Service<\/p>\n<p>Protection<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>LSP\/PW Linear protection, Ring protection<\/p>\n<p>Anti multifailure protection based on MS-PW<\/p>\n<p>LAG, MC-LAG, Dual-homing protection, LPT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>SDH based Service<\/p>\n<p>Protection<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>2\/4 fiber MS-SP Ring;<\/p>\n<p>1+1\/1:n (n&lt;=14) Linear MSP<\/p>\n<p>SNCP\/SNCTP<\/p>\n<p>Tributary protection for E1\/T1, E3\/T3, E4, STM-1(e) and FE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>ASON<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">\n<p>Distributed restorable rerouting protection<\/p>\n<p>5-level service dedicated protection scheme based on different SLA: Diamond, Gold, Silver, Copper and Iron services<\/p>\n<p>Based on VC-4 and VC-12 granularity<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\">\n<p><strong>Synchronization<\/strong><strong><\/strong><\/p>\n<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">\n<p>Both Ethernet and SDH networks supporting clock synchronization<\/p>\n<p>Supporting G.813, Synchronous Ethernet and IEEE 1588v2 synchronization<\/p>\n<p>Adaptive clock recovery (ACR)<\/p>\n<p>Two external clock inputs\/outputs (2 MHz or 2 Mbit\/s)<\/p>\n<p>Two external time signals (1pps+TOD)<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<table>< tbody > <\/p>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>TNNS0VBSWF15 &#8211; Huawei OSN 7500 II Basic  Software<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td itemprop=\"description\">OptiX OSN 7500 II-Basic Software Package,V200R015(Per Subrack)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":62695,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[1500],"product_tag":[],"class_list":{"0":"post-36705","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-huawei-transmission-network-huawei-optix-osn-7500-ii-huawei-huawei-transmission-network","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/36705","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=36705"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/62695"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=36705"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=36705"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=36705"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=36705"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}