{"id":35600,"date":"2025-09-29T14:44:19","date_gmt":"2025-09-29T14:44:19","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=35600"},"modified":"2025-09-29T14:44:20","modified_gmt":"2025-09-29T14:44:20","slug":"tnn1ixcs","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/tnn1ixcs\/","title":{"rendered":"TNN1IXCS"},"content":{"rendered":"<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td colspan=\"5\" valign=\"top\" width=\"568\">\n<h3 align=\"center\"><strong>TNN1IXCS<\/strong><strong>\u00a0Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>Part Number<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">03022LJU<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>Model<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">TNN1IXCS<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>Description<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">Infinite Cross-connect and Synchronous Timing Board<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>Discount Category<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">Main Equipment<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>Product Line<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">Networking<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>Sub Product Family<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">MSTP<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>Product Series<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">OSN 7500 II<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>UOM<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">PCS<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>Net Dimension(D*W*H mm)<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">271*40*294<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>Typic Power(W)<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" valign=\"top\" width=\"568\">\n<p align=\"center\"><strong>Huawei OSN 7500 II<\/strong><strong>\u00a0<\/strong><strong>Specification<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>Dimensions<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">800mm (H) x 496mm (W) x 295mm (D)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>Switch Capacity<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">Packet: 320 Gbit\/s and TDM: 360 Gbit\/s (higher order), 40 Gbit\/s (lower order), OTN: 560Gbit\/s<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>Service Slots<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">32 slots, 16 slots for interface boards and 16 slots for processing boards with same bandwidth per slot<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"9\" valign=\"top\" width=\"147\"><strong>Supported Interface<\/strong><\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">OTN interface<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">OTU-1, OTU-2\/2e, OTU-3(40G, compliant with OTL3.4 standard)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">Ethernet interface<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">FE\/GE\/10GE\/40GE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">SDH interface<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">STM-1\/4\/16\/64<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">PDH interface<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">E1\/T1, E3\/T3, E4<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">ATM interface<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">E1, STM-1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">WDM interface<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">40 DWDM wavelengths, compliant with ITU-T G.694.1<\/p>\n<p>8 CWDM wavelengths, compliant with ITU-T G.694.2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">SAN interface<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">FDDI, ESCON, FICON\/FICON Express, FC100\/200\/400\/800\/1200<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">PCM interface<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">FXS\/FXO, 2\/4W VF &amp; E&amp;M<\/p>\n<p>X.21\/V.35\/V.11\/V.24\/V.28, RS232\/RS422, RS449\/RS423A\/RS422A, RS530\/RS530A,RS485, G.703 64 kbit\/s codirectional<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">Other interface<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">DDN, Video<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>Networking Mode<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">Supports packet, hybrid (packet + SDH or OTN + SDH) or SDH networking<\/p>\n<p>Supporting WDM networking<\/p>\n<p>Supporting single-fiber bidirectional transmission<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>Power Supply<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">-48V DC\/-60V DC<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" valign=\"top\" width=\"147\"><strong>Operation<\/strong><\/p>\n<p><strong>Environment<\/strong><\/td>\n<td valign=\"top\" width=\"140\">&nbsp;<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"140\">Temperature<\/td>\n<td valign=\"top\" width=\"140\">Relative Humidity<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"140\">Long term<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"140\">0<span style=\"font-family: \u00e5\u00ae\u2039\u00e4\u00bd\u201c;\">\u00ba<\/span><span style=\"font-family: Calibri;\">C ~ 45<\/span><span style=\"font-family: \u00e5\u00ae\u2039\u00e4\u00bd\u201c;\">\u00ba<\/span><span style=\"font-family: Calibri;\">C<\/span><\/td>\n<td valign=\"top\" width=\"140\">5% ~ 85%<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"140\">Short term<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"140\">-5<span style=\"font-family: \u00e5\u00ae\u2039\u00e4\u00bd\u201c;\">\u00ba<\/span><span style=\"font-family: Calibri;\">C ~ 55<\/span><span style=\"font-family: \u00e5\u00ae\u2039\u00e4\u00bd\u201c;\">\u00ba<\/span><span style=\"font-family: Calibri;\">C<\/span><\/td>\n<td valign=\"top\" width=\"140\">5% ~ 95%<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>Ethernet Feature<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">E-Line and E-LAN, QinQ<\/p>\n<p>MPLS-TP based VPWS and VPLS<\/p>\n<p>Multi-section pseudo-wire (MS-PW)<\/p>\n<p>ETH PWE3, TDM PWE3, A TM\/IMA PWE3<\/p>\n<p>IGMP Snooping V2<\/p>\n<p>Blacklist, Broadcast packet suppression, ACL<\/p>\n<p>VLAN SWAP<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>PCM Feature<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">Voice or data Conference\/Meeting,P2MP,MP2MP<\/p>\n<p>FXO\/FXS mode can be set by software<\/p>\n<p>E&amp;M Interface voltage can be set by software (-48V\/-12V)<\/p>\n<p>E&amp;M signaling can be set by software (Bell types I, II, III, IV, V and British Telecom SSDC5)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>QoS<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">Hierarchical QoS scheduling and traffic shaping<\/p>\n<p>DiffServ mode based on traffic classification, eight priority queues<\/p>\n<p>Simple traffic classification, complex traffic classification, per hop behavior (PHB),and A CL<\/p>\n<p>Committed access rate (CAR), shaping based on port scheduling priority<\/p>\n<p>PQ scheduling priority, weighted fair queuing (WFQ) and PQ+WFQ queuing<\/p>\n<p>Tail drop and weighted random early detection (WRED)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" valign=\"top\" width=\"147\"><strong>OAM<\/strong><\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">MPLS-TP OAM<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">LSP\/PW OAM:<\/p>\n<p>CC, LB, LT<\/p>\n<p>AIS, RDI<\/p>\n<p>LM, DM<\/p>\n<p>LCK, TST<\/p>\n<p>CSF<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">MPLS OAM<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">LSP\/PW OAM: FDI, BDI,CV, FFD, TraceRoute, Ping, LM, DM<\/p>\n<p>PW OAM: CES PW VCCV<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">Ethernet OAM<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">ETH-CC, ETH-Loopback, ETH-Link Trace, Remote Loopback, Remote Fault Detection, RMON(RFC 2819)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" valign=\"top\" width=\"147\"><strong>Protection<\/strong><\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">Equipment-level Protection<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">Universal Cross-Connect, System Control and Clock Processing Board 1+1 backup and power 1+1 backup<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">MPLS-TP based Service<\/p>\n<p>Protection<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">LSP\/PW Linear protection, Ring protection<\/p>\n<p>Anti multifailure protection based on MS-PW<\/p>\n<p>LAG, MC-LAG, Dual-homing protection, LPT<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">SDH based Service<\/p>\n<p>Protection<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">2\/4 fiber MS-SP Ring;<\/p>\n<p>1+1\/1:n (n&lt;=14) Linear MSP<\/p>\n<p>SNCP\/SNCTP<\/p>\n<p>Tributary protection for E1\/T1, E3\/T3, E4, STM-1(e) and FE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"210\">ASON<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"210\">Distributed restorable rerouting protection<\/p>\n<p>5-level service dedicated protection scheme based on different SLA: Diamond, Gold, Silver, Copper and Iron services<\/p>\n<p>Based on VC-4 and VC-12 granularity<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"147\"><strong>Synchronization<\/strong><\/td>\n<td colspan=\"4\" valign=\"top\" width=\"420\">Both Ethernet and SDH networks supporting clock synchronization<\/p>\n<p>Supporting G.813, Synchronous Ethernet and IEEE 1588v2 synchronization<\/p>\n<p>Adaptive clock recovery (ACR)<\/p>\n<p>Two external clock inputs\/outputs (2 MHz or 2 Mbit\/s)<\/p>\n<p>Two external time signals (1pps+TOD)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>&lt; tbody &gt;<\/p>\n<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>TNN1IXCS &#8211; Huawei OSN 7500 II Main Equipment<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>Infinite Cross-connect and Synchronous Timing Board<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":62476,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[1500],"product_tag":[],"class_list":{"0":"post-35600","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-huawei-transmission-network-huawei-optix-osn-7500-ii-huawei-huawei-transmission-network","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/35600","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=35600"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/62476"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=35600"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=35600"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=35600"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=35600"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}