{"id":3465,"date":"2025-09-29T10:39:57","date_gmt":"2025-09-29T10:39:57","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=3465"},"modified":"2025-09-29T10:39:58","modified_gmt":"2025-09-29T10:39:58","slug":"pwr-c45-6000acv","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/pwr-c45-6000acv\/","title":{"rendered":"PWR-C45-6000ACV"},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<h3 align=\"center\"><strong>PWR-C45-6000ACV Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>AC-input type<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Autoranging inputs with power factor correction<\/p>\n<p>Note&nbsp;Power factor correction is a standard feature on all Catalyst 4500 E-series AC-input power supplies. PFC reduces the reactive component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current components.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>AC-input voltage<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Low-line (120 VAC nominal)&mdash;85 VAC (min) to 132 VAC (max)<\/p>\n<p>High-line (230 VAC nominal)&mdash;170 VAC (min) to 264 VAC (max)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>AC-input current<\/p>\n<\/td>\n<td valign=\"top\">\n<p>12 A (max) @ 120 VAC (for each input)<\/p>\n<p>16 A (max) @ 230 VAC (for each input)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>AC-input frequency<\/p>\n<\/td>\n<td valign=\"top\">\n<p>50\/60 Hz (nominal) (&plusmn;3% for full range)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Power supply output<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Total output depends on the number of inputs connected and the source AC voltage. If two inputs are used, they should both be of the same AC voltage.<\/p>\n<p>1050 W operation (with one 120 VAC nominal input)<\/p>\n<p>&ndash;&nbsp;70.8 A @ 12 VDC (data only)<\/p>\n<p>&ndash;&nbsp;12.5 A @ 3.3 VDC (data only)<\/p>\n<p>&ndash;&nbsp;18.4 A @ &ndash;50 VDC (PoE if used)<\/p>\n<p>2100 W operation (with two 120 VAC nominal inputs)<\/p>\n<p>&ndash;&nbsp;141.6 A @ 12 VDC (data only)<\/p>\n<p>&ndash;&nbsp;12.5 A @ 3.3 VDC (data only)<\/p>\n<p>&ndash;&nbsp;37.0 A @ &ndash;50 VDC (PoE if used)<\/p>\n<p>3000 W operation (with one 230 VAC nominal input)<\/p>\n<p>&ndash;&nbsp;183.3 A @ 12 VDC (data only)<\/p>\n<p>&ndash;&nbsp;12.5 A @ 3.3 VDC (data only)<\/p>\n<p>&ndash;&nbsp;48 A @ &ndash;50 VDC (PoE if used)<\/p>\n<p>6000 W operation (with two 230 VAC nominal inputs)<\/p>\n<p>&ndash;&nbsp;183.3 A @ 12 VDC (data only)<\/p>\n<p>&ndash;&nbsp;12.5 A @ 3.3 VDC (data only)<\/p>\n<p>&ndash;&nbsp;96 A @ &ndash;50 VDC (PoE if used)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Power supply output capacity<\/p>\n<\/td>\n<td valign=\"top\">\n<p>6000 W maximum<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Output holdup time<\/p>\n<\/td>\n<td valign=\"top\">\n<p>20 ms minimum<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>kVA rating<a href=\"https:\/\/www.cisco.com\/c\/en\/us\/td\/docs\/switches\/lan\/catalyst4500\/hardware\/catalyst4500e\/installation\/guide\/Eseries\/0aspecs.html#pgfId-1057110\" target=\"_blank\" rel=\"noopener\">5<\/a><\/p>\n<\/td>\n<td valign=\"top\">\n<p>6.8 kVA (power factor = 0.99)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Heat dissipation<\/p>\n<\/td>\n<td valign=\"top\">\n<p>2,720 BTUs\/hr (approx.)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Minimum software requirement<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Cisco IOS Release 12.2(52)SG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Power over Ethernet<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Supported, up to 4800 W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<p align=\"center\"><strong>LEDs and Meanings<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>INPUT OK<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Green&mdash;Source AC voltage is OK. (Input voltage is 85 VAC or greater.)<\/p>\n<p>Off&mdash;Source AC voltage falls below 70 VAC, is not present, or the power supply is turned off.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>FAN OK<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Green&mdash;Power supply fan is operating properly.<\/p>\n<p>Off&mdash;Power supply fan failure is detected.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>OUTPUT FAIL<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Red&mdash;Problem with one or more of the DC-output voltages of the power supply is detected.<\/p>\n<p>Off&mdash;DC-output voltage with acceptable margins.<\/p>\n<p>Note&nbsp;For proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray assembly and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray assembly, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<table>< tbody > <\/p>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>PWR-C45-6000ACV Cisco Catalyst 4500 PoE Enabled Power Supply<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td itemprop=\"description\">Cisco Catalyst 4500 Power Supply PWR-C45-6000ACV Catalyst 4500 6000W AC dual input Power Supply (Data + PoE)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":53305,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[456],"product_tag":[],"class_list":["post-3465","product","type-product","status-publish","has-post-thumbnail","product_cat-cisco-power-supply-catalyst-4500-switch-power-supply-cisco","first","instock","sale","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/3465","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=3465"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/53305"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=3465"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=3465"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=3465"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=3465"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}