{"id":34531,"date":"2025-09-29T14:29:56","date_gmt":"2025-09-29T14:29:56","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=34531"},"modified":"2025-09-29T14:29:56","modified_gmt":"2025-09-29T14:29:56","slug":"s2350-28tp-pwr-ei-ac","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/s2350-28tp-pwr-ei-ac\/","title":{"rendered":"S2350-28TP-PWR-EI-AC"},"content":{"rendered":"<table border=\"1\">\n<thead>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"100%\">\n<h3 align=\"center\"><strong>S2350-28TP-PWR-EI-AC Specifications<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"100%\">\n<p align=\"center\"><strong>Technical Specifications<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Item<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Memory (RAM)<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>256 MB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Flash<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>200 MB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Mean time between failures (MTBF)<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>78.29 years<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Mean time to repair (MTTR)<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>2 hours<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Availability<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>&gt; 0.99999<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Service port surge protection<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>Common mode: &plusmn;6 kV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Power supply surge protection<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>&plusmn;6 kV in differential mode, &plusmn;6 kV in common mode<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Dimensions (W x D x H)<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>442.0 mm x 310.0 mm x 43.6 mm (17.4 in. x 12.2 in. x 1.72 in.)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Weight<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>&le; 5 kg (11.02 lb)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Stack ports<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>Two uplink 1000Base-X optical ports<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>RPS<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>Not supported<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>PoE<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>Supported<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Rated voltage range<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>100 V AC to 240 V AC, 50\/60 Hz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Maximum voltage range<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>90 V AC to 264 V AC, 47 Hz to 63 Hz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Maximum power consumption (100% throughput, 100% PoE loads, full speed of fans)<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>445 W (system power consumption: 75 W, PoE: 370 W)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Operating temperature<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>-5&deg;C to +50&deg;C (23&deg;F to 122&deg;F) at an altitude of 0-1800 m (0-5096 ft.)<\/p>\n<p>NOTE\u00ef\u00bc\u0161<\/p>\n<p>When the altitude is between 1800 m (5096 ft.) and 5000 m (16404 ft.), the highest operating temperature reduces by 1&deg;C (1.8&deg;F) every time the altitude increases by 220 m (722 ft.).<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Storage temperature<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>-40&deg;C to +70&deg;C (-40&deg;F to +158&deg;F)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Noise under normal temperature (27&deg;C, sound power)<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>&lt; 52 dBA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Relative humidity<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>5% to 95%, noncondensing<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Operating altitude<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>0-5000 m (0-16404 ft.)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Certification<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>&middot;EMC certification<\/p>\n<p>&middot;Safety certification<\/p>\n<p>&middot;Manufacturing certification<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"100%\">\n<p align=\"center\"><strong>Performance Specifications<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Ethernet<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>MAC:16K<\/p>\n<p>VLAN:4K<\/p>\n<p>Maximum number of Eth-Trunks:8<\/p>\n<p>Maximum number of dynamic ARP entries in the system:256<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>QoS<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>Maximum number of outbound QoS queues on an interface:8<\/p>\n<p>CAR:8 Kbit\/s<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>ACL<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>ACLv4: Supports a maximum of 500 inbound and outbound ACLv4 entries.<\/p>\n<p>ACLv6: Supports a maximum of 500 inbound and outbound ACLv6 entries.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>IP unicast<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>IPv4 Route capacity:32<\/p>\n<p>IPv6 Route capacity:16<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Multicast<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>Number of multicast groups on the switch:1K<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p>Reliability<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p>RRPP:<\/p>\n<p>&middot;Maximum number of RRPP instances: 64<\/p>\n<p>&middot;Maximum number of RRPP rings: 16<\/p>\n<p>&middot;Maximum number of RRPP domains: 8<\/p>\n<p>Smart Link:<\/p>\n<p>&middot; Maximum number of instances: 64<\/p>\n<p>&middot; Maximum number of Smart Link groups: 16<\/p>\n<p>MSTP:<\/p>\n<p>&middot; Maximum number of MSTIs: 64<\/p>\n<p>VBST:<\/p>\n<p>&middot;Number of protected VLANs: 128<\/p>\n<p>SEP:<\/p>\n<p>&middot;Maximum number of segments: 16<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<table>< tbody > <\/p>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>S2350-28TP-PWR-EI-AC Huawei S2300 Series Switch<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td itemprop=\"description\">S2350-28TP-PWR-EI-AC(24 Ethernet 10\/100 PoE+ ports,2 Gig SFP and 2 dual-purpose 10\/100\/1000 or SFP,AC 110\/220V)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":62325,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[1510],"product_tag":[],"class_list":{"0":"post-34531","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-huawei-switches-huawei-s2300-series-switches-huawei","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/34531","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=34531"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/62325"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=34531"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=34531"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=34531"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=34531"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}