{"id":34415,"date":"2025-09-29T14:28:29","date_gmt":"2025-09-29T14:28:29","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=34415"},"modified":"2025-09-29T14:28:29","modified_gmt":"2025-09-29T14:28:29","slug":"le0ks9306","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/le0ks9306\/","title":{"rendered":"LE0KS9306"},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"100%\">\n<h3 align=\"center\"><strong>LE0KS9306 Specifications<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">Packet forwarding rate<\/td>\n<td valign=\"top\" width=\"72%\">2880Mpps<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">Switching capacity<\/td>\n<td valign=\"top\" width=\"72%\">3.84Tbps<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">Service slot quantity<\/td>\n<td valign=\"top\" width=\"72%\">6<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">User management<\/td>\n<td valign=\"top\" width=\"72%\">Unified user management<\/p>\n<p>802.1x, MAC, and Portal authentications<\/p>\n<p>Charging based on traffic volume and online duration<\/p>\n<p>User authorization based on user groups, domains, and time ranges<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">VLAN<\/td>\n<td valign=\"top\" width=\"72%\">Access, trunk, and hybrid<\/p>\n<p>Default VLAN<\/p>\n<p>VLAN switching<\/p>\n<p>QinQ and selective QinQ<\/p>\n<p>MAC-based VLAN assignment<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">MAC address<\/td>\n<td valign=\"top\" width=\"72%\">MAC address learning and aging<\/p>\n<p>Static, dynamic, and blackhole MAC address entries<\/p>\n<p>Packet filtering based on source<\/p>\n<p>MAC addresses MAC address limiting based on ports and VLANs<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">STP\/ERPS<\/td>\n<td valign=\"top\" width=\"72%\">STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s)<\/p>\n<p>BPDU protection, root protection, and loop protection<\/p>\n<p>BPDU tunnel<\/p>\n<p>G.8032 Ethernet Ring Protection Switching (ERPS)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">IP routing<\/td>\n<td valign=\"top\" width=\"72%\">IPv4 dynamic routing protocols, such as RIP, OSPF, IS-IS, and BGP<\/p>\n<p>IPv6 routing protocols, such as RIPng, OSPFv3, IS-ISv6, and BGP4+<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">Multicast<\/td>\n<td valign=\"top\" width=\"72%\">IGMPv1\/v2\/v3 and IGMP v1\/v2\/v3 snooping<\/p>\n<p>PIM-DM, PIM-SM, and PIM-SSM<\/p>\n<p>MSDP and MBGP<\/p>\n<p>Prompt leave<\/p>\n<p>Multicast traffic control<\/p>\n<p>Multicast querier<\/p>\n<p>Multicast protocol packet suppression<\/p>\n<p>Multicast CAC<\/p>\n<p>Multicast ACL<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">MPLS<\/td>\n<td valign=\"top\" width=\"72%\">Basic MPLS functions<\/p>\n<p>MPLS OAM<\/p>\n<p>MPLS TE<\/p>\n<p>MPLS VPN\/VLL\/VPLS<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">Reliability<\/td>\n<td valign=\"top\" width=\"72%\">LACP and inter-chassis E-Trunk<\/p>\n<p>VRRP and BFD for VRRP<\/p>\n<p>BFD for BGP\/IS-IS\/OSPF\/static route<\/p>\n<p>NSF and GR for BGP\/IS-IS\/OSPF\/LDP<\/p>\n<p>TE FRR and IP FRR<\/p>\n<p>Ethernet OAM in compliance with IEEE 802.3ah and 802.1ag (hardware-level) ITU-Y.1731<\/p>\n<p>DLDP<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">QoS<\/td>\n<td valign=\"top\" width=\"72%\">Traffic classification based on Layer 2 headers, Layer 3 protocols, Layer 4 protocols, and 802.1p fields<\/p>\n<p>ACL, CAR, and actions including Remark and Schedule<\/p>\n<p>Queuing algorithms, such as SP, WRR, DRR, SP+WRR, and SP+DRR<\/p>\n<p>Congestion avoidance mechanisms, including WRED and tail drop<\/p>\n<p>H-QOS<\/p>\n<p>Traffic shaping<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">Configuration and maintenance<\/td>\n<td valign=\"top\" width=\"72%\">iPCA, monitor network quality for any service flow at any network node, at any time, and without extra costs<\/p>\n<p>Terminal access services such as console port login, Telnet, and SSH<\/p>\n<p>Network management protocols, such as SNMPv1\/v2\/v3<\/p>\n<p>File uploading and downloading through FTP and TFTP<\/p>\n<p>BootROM upgrade and remote in-service upgrade<\/p>\n<p>Hot patches<\/p>\n<p>User operation logs<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">Security and user management<\/td>\n<td valign=\"top\" width=\"72%\">802.1x authentication and Portal authentication<\/p>\n<p>NAC<\/p>\n<p>RADIUS and HWTACACS authentication for login users<\/p>\n<p>Command line authority control based on user levels (unauthorized users cannot use commands)<\/p>\n<p>Defense against DoS attacks, TCP SYN Flood attacks, UDP Flood attacks, broadcast storms, and traffic flooding attacks<\/p>\n<p>1K CPU queues<\/p>\n<p>Ping and traceroute<\/p>\n<p>RMON<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">Security protection<\/td>\n<td valign=\"top\" width=\"72%\">Firewall<\/p>\n<p>Network Address Translation (NAT)<\/p>\n<p>IPSec, SSL VPN<\/p>\n<p>Intrusion Protection System (IPS)<\/p>\n<p>Load balancing Analog Digital Conversion (ADC)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">Energy saving<\/td>\n<td valign=\"top\" width=\"72%\">Energy Efficient Ethernet (802.3az)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">LPU slots<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">6<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">MPU slots<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">Fan slots<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">System power supply slots<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">PoE power supply slots<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">Maximum port density<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">\u00b7V100R006C00 and V200R001C00: 288xFE, 288xGE, 240x10GE<\/p>\n<p align=\"left\">\u00b7V200R002C00 to V200R007C00: 288xFE, 288xGE, 240x10GE, 12x40GE<\/p>\n<p align=\"left\">\u00b7V200R008C00 to V200R009C00: 288xFE, 288xGE, 240x10GE, 12x40GE, 12x100GE<\/p>\n<p align=\"left\">\u00b7V200R010C00 and later versions: 288xFE, 288xGE, 288x10GE, 48x40GE, 24x100GE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">Installation<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">In an N66E or N68E cabinet, one or two chassis in a cabinet<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">CSS<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">CSS card or service port clustering<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">PoE<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">\u00b7Power input: Versions earlier than V200R006C00 support only AC power supply. V200R006C00 and later versions support both AC power supply and DC power supply (only 2200 W DC power modules).<\/p>\n<p align=\"left\">\u00b7PoE power module backup: no backup, 3+1 backup, or 2+2 backup<\/p>\n<p align=\"left\">\u00b7Maximum output power: 8800 W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">Maximum power consumption (fully loaded, no PoE power supply)<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">2200 W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">Power specifications<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">\u00b7DC input voltage<\/p>\n<p align=\"left\">Rated voltage: -48 V DC\/-60 V DC<\/p>\n<p align=\"left\">Maximum voltage range:<\/p>\n<p align=\"left\">1600 W\/2400 W\u00a0DC power module: -38.4 V DC to -72 V DC<\/p>\n<p align=\"left\">2200 W DC power module: -40 V DC to -72 V DC<\/p>\n<p align=\"left\">\u00b7AC input voltage<\/p>\n<p align=\"left\">Rated voltage: 110 V AC\/220 V AC, 50\/60 Hz<\/p>\n<p align=\"left\">Maximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The output power reduces to half of the maximum output when the input voltage is in the range of 90 V AC to 175 V AC.)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">Dimensions (W x D x H, excluding rack-mounting brackets)<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">\u00b7With cable management frames: 442 mm x 585 mm x 441.7 mm (17.4 in. x 23.0 in. x 17.39 in. (10 U))<\/p>\n<p align=\"left\">\u00b7Without cable management frames: 442 mm x 489 mm x 441.7 mm (17.4 in. x 19.3 in. x 17.39 in. (10 U))<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">Weight (empty\/fully loaded)<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">15 kg\/42 kg (33.1 lb\/92.6 lb)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">Reliability and availability<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">MTBF: 24.2 years<\/p>\n<p align=\"left\">MTTR: 52 minutes<\/p>\n<p align=\"left\">Availability: 0.9999959<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">Environment parameters<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">\u00b7Operating temperature and altitude:<\/p>\n<p align=\"left\">-60 m to +1800 m (197 ft. to 5906 ft.): 0\u00b0C to 45\u00b0C (32\u00b0F to 113\u00b0F)<\/p>\n<p align=\"left\">1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1\u00b0C (1.8\u00b0F) every time the altitude increases 220 m (722 ft.).<\/p>\n<p align=\"left\">4000 m (13123 ft.): 0\u00b0C to 35\u00b0C (32\u00b0F to 95\u00b0F)<\/p>\n<p align=\"left\">\u00b7Operating relative humidity: 5% RH to 95% RH (noncondensing)<\/p>\n<p align=\"left\">\u00b7Storage temperature: -40\u00b0C to +70\u00b0C (-40\u00b0F to +158\u00b0F)<\/p>\n<p align=\"left\">\u00b7Storage altitude: &lt; 5000 m (16404 ft.)<\/p>\n<p align=\"left\">\u00b7Storage relative humidity: 5% RH to 95% RH (noncondensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">Noise at normal temperature (acoustic power)<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">\u2264 72 dBA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">EMC compliance<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">CISPR22 Class A<\/p>\n<p align=\"left\">CISPR24<\/p>\n<p align=\"left\">EN55022 Class A<\/p>\n<p align=\"left\">EN50024<\/p>\n<p align=\"left\">ETSI EN 300 386 Class A<\/p>\n<p align=\"left\">ICES 003 Class A<\/p>\n<p align=\"left\">AS\/NZS CISPR22 Class A<\/p>\n<p align=\"left\">VCCI Class A<\/p>\n<p align=\"left\">IEC61000-6-2<\/p>\n<p align=\"left\">IEC61000-6-4<\/p>\n<p align=\"left\">IEC61000-4-2<\/p>\n<p align=\"left\">ITU-T K 20<\/p>\n<p align=\"left\">ITU-T K 21<\/p>\n<p align=\"left\">ITU-T K 44<\/p>\n<p align=\"left\">CNS13438 CLASS A<\/p>\n<p align=\"left\">KN 22 CLASS A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">Environmental standards compliance<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">RoHS<\/p>\n<p align=\"left\">REACH<\/p>\n<p align=\"left\">WEEE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"27%\">\n<p align=\"left\">Safety standards compliance<\/p>\n<\/td>\n<td valign=\"top\" width=\"72%\">\n<p align=\"left\">IEC 60950-1<\/p>\n<p align=\"left\">EN 60950-1<\/p>\n<p align=\"left\">UL 60950-1<\/p>\n<p align=\"left\">CSA C22.2 No 60950-1<\/p>\n<p align=\"left\">AS\/NZS 60950.1<\/p>\n<p align=\"left\">BS EN 60950-1<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>&lt; tbody &gt;<\/p>\n<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>LE0KS9306 Huawei S9300 Series Switch<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>S9306 Assembly Chassis<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":62317,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[1514],"product_tag":[],"class_list":["post-34415","product","type-product","status-publish","has-post-thumbnail","product_cat-huawei-switches-huawei-s9300-series-switches-huawei","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/34415","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=34415"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/62317"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=34415"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=34415"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=34415"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=34415"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}