{"id":34177,"date":"2025-09-29T14:25:28","date_gmt":"2025-09-29T14:25:28","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=34177"},"modified":"2025-09-29T14:25:28","modified_gmt":"2025-09-29T14:25:28","slug":"s5700-52c-pwr-ei-ac","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/s5700-52c-pwr-ei-ac\/","title":{"rendered":"S5700-52C-PWR-EI-AC"},"content":{"rendered":"<table width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<th colspan=\"2\" bgcolor=\"#e6e6e6\">Item<\/th>\n<th bgcolor=\"#e6e6e6\">S5700(S)-LI\/S5710-LI*<\/th>\n<th bgcolor=\"#e6e6e6\">S5700-SI*<\/th>\n<th bgcolor=\"#e6e6e6\">S5700-EI\/S5710-EI\/S5720-EI*<\/th>\n<th bgcolor=\"#e6e6e6\">S5700-HI\/S5710-HI\/S5720-HI*<\/th>\n<\/tr>\n<tr>\n<td rowspan=\"36\">Fixed port<\/td>\n<td rowspan=\"9\">LI<\/td>\n<td colspan=\"4\">S5700-10P-LI-AC\/S5700-10P-PWR-LI-AC: 8 \u00d7 10\/100\/1000Base-T,2 \u00d7 1000Base-X SFP<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5700(S)-28P-LI\/S5700-28P-PWR-LI\/ S5700-28P-LI-BAT\/S5700-28P-LI-4AH: 24 \u00d7 10\/100\/1000Base-T, 4 \u00d7 1000Base-X SFP<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5700-28P-LI-24S-BAT\/S5700-28P-LI-24S-4AH: 28 \u00d7 1000Base-X,4 of which are dual-purpose 10\/100\/1000 or SFP, 4 \u00d7 1000Base-X<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5700-28TP-LI-AC\/S5700-28TP-PWR-LI-AC\/S5701-28TP-PWR-LI-AC: 24\u00d7 10\/100\/1000Base-T, 2\u00d71000Base-X SFP and 2 dual-purpose 10\/100\/1000 or SFP<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5700-28X-LI\/S5700-28X-PWR-LI-AC\/ S5701-28X-LI-AC: 24 \u00d7 10\/100\/1000Base-T, 4 \u00d7 10GE SFP+<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5700-28X-LI-24S-AC\/S5700-28X-LI-24S-DC\/ S5701-28X-LI-24S-AC: 28x1000Base-X,4 of which are dual-purpose 10\/100\/1000 or SFP,4 \u00d7 10GE SFP+<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5700(S)-52P-LI\/S5700-52P-PWR-LI: 48 \u00d7 10\/100\/1000Base-T, 4 \u00d7 1000Base-X SFP<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5700-52X-LI\/S5700-52X-PWR-LI-AC: 48 \u00d7 10\/100\/1000Base-T, 4 \u00d7 10GE SFP+<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5700-52X-LI-48CS-AC:48x1000Base-X(CSFP) or 24 \u00d7 1000Base-X, 4 of which are dual-purpose 10\/100\/1000 or Base-X(CSFP), 4 \u00d7 10GE SFP+<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">SI<\/td>\n<td colspan=\"4\">S5700-24TP-SI\/S5700-24TP-PWR-SI\/S5700-28C-SI\/S5700-28C-PWR-SI:24 \u00d7 10\/100\/1000Base-T, 4 of which are dual-purpose 10\/100\/1000 or SFP<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5700-26X-SI-12S-AC: 12 \u00d7 10\/100\/1000BASE-T,12\u00d7100\/1000Base-X,2 \u00d7 10GE SFP+<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5700-48TP-SI\/S5700-48TP-PWR-SI: 48 \u00d7 10\/100\/1000Base-T, 4 of which are dual-purpose 10\/100\/1000 or SFP<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5700-52C-SI\/S5700-52C-PWR-SI: 48 \u00d7 10\/100\/1000Base-T<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"18\">EI<\/td>\n<td colspan=\"4\">S5700-28C-EI\/S5700-28C-PWR-EI: 24 \u00d7 10\/100\/1000Base-T<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5700-52C-EI\/S5700-52C-PWR-EI: 48 \u00d7 10\/100\/1000Base-T<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5700-28C-EI-24S: 20 \u00d7 100\/1000Base-X, 4 \u00d7 GE Combo<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5710-28C-EI\/S5710-28C-PWR-EI-AC: 20 x 10\/100\/1000Base-T, 4 \u00d7 GE Combo, 4 \u00d7 10GE SFP+<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5710-52C-EI\/S5710-52C-PWR-EI\/S5710-52C-PWR-EI-AC: 48 x 10\/100\/1000Base-T, 4 \u00d7 10GE SFP+<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5720-32P-EI-AC: 24\u00d710\/100\/1000Base-T, 4\u00d7100\/1000Base-X SFP, 4 Gig SFP<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5720-52P-EI-AC:48\u00d710\/100\/1000Base-T, 4 Gig SFP<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5720-36C-EI-AC\/S5720-36C-PWR-EI-AC: 28\u00d710\/100\/1000Base-T(4GE Combo SFP), 4\u00d710 GE SFP+<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5720-36C-EI-28S-AC:28\u00d7100\/1000Base-X SFP(4GE Combo), 4\u00d710GE SFP+<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5720-36PC-EI-AC: 28\u00d710\/100\/1000Base-T(4GE Combo SFP), 4 Gig SFP<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5720-56C-EI-AC\/S5720-56C-PWR-EI-AC\/S5720-56C-PWR-EI-AC1:48\u00d710\/100\/1000Base-T, 4\u00d710GE SFP+<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5720-56C-EI-48S-AC: 48\u00d7100\/1000Base-X SFP, 4\u00d710GE SFP+<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5720-56PC-EI-AC: 48\u00d710\/100\/1000Base-T, 4 Gig SFP<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" valign=\"top\">S5720-32X-EI-AC: 24\u00d710\/100\/1000 Base-T, 4\u00d7100\/1000Base-X SFP, 4\u00d710 GE SFP+<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" valign=\"top\">S5720-32X-EI-24S-AC: 24\u00d7100\/1000Base-X SFP, 4\u00d710\/100\/1000Base-T, 4\u00d710GE SFP+<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" valign=\"top\">S5720-50X-EI-AC : 46 \u00d710\/100\/1000Base-T, 4\u00d710GE SFP+<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" valign=\"top\">S5720-50X-EI-46S-AC: 46 \u00d7100\/1000Base-X SFP, 4\u00d710GE SFP+<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" valign=\"top\">S5720-52X-EI-AC: 48\u00d710\/100\/1000Base-T, 4\u00d710GE SFP+<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">HI<\/td>\n<td colspan=\"4\">S5700-28C-HI: 24 \u00d7 10\/100\/1000Base-T<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5700-28C-HI-24S: 24 \u00d7 100\/1000Base-X<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5710-108C-PWR-HI: 48 \u00d7 10\/100\/1000BASE-T, 8 \u00d7 10GE SFP+<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5720-32C-HI-24S-AC: 24\u00d7100\/1000Base-X ,8 of which are dual-purpose 10\/100\/1000 or SFP, 4\u00d710GE SFP+<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5720-56C-HI-AC\/S5720-56C-PWR-HI-AC: 48\u00d710\/100\/1000Base-T, 4\u00d710GE SFP+<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"5\">MAC address table<\/td>\n<td colspan=\"4\">IEEE 802.1d compliance<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">MAC address learning and aging<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Static, dynamic, and blackhole MAC address entries<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Packet filtering based on source MAC addresses<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">MAC address entries:<br \/>\nS5700S-LI series: 8K, S5700-LI\/S5700-SI series: 16K, S5700-EI series: 32K, S5720-EI series: 64K, S5700-HI series: S5700-HI: 32K, S5710-HI: 456K, S5720-HI: 128K<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"7\">VLAN<\/td>\n<td colspan=\"4\">4K VLANs<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Guest VLAN and voice VLAN<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">GVRP<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">MUX VLAN<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">1:1 and N:1 VLAN Mapping<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">SuperVLAN(supported by the S5700-SI\/S5700-EI\/S5700-HI series)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"7\">Ring protection<\/td>\n<td colspan=\"4\">RRPP ring topology and RRPP multi-instance<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">SEP<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">ERPS(G.8032)(supported by the S5700-LI\/S5700-SI\/S5700-EI\/S5700-HI series)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">STP, RSTP, and MSTP<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">BPDU protection, root protection, and loop protection<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">BPDU Tunnel<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"6\">Reliability<\/td>\n<td colspan=\"4\">Ethernet OAM (IEEE 802.3ah and 802.1ag)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">ITU-Y.1731<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">DLDP<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">LACP<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">E-Trunk(supported by the S5700-SI\/S5700-EI\/S5700-HI series)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM (supported by the S5700-EI\/S5700-HI series)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"5\">MPLS features<\/td>\n<td colspan=\"4\">MPLS L3VPN<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">MPLS L2VPN(VPWS\/VPLS)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">MPLS-TE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">MPLS QoS<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Notes: supported by S5710-EI, S5700-HI and S5710-HI<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"3\">IP routing<\/td>\n<td colspan=\"4\">Static routing<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">RIPv1, RIPv2 and RIPng,ECMP(supported by the S5700-SI\/S5700-EI\/S5700-HI series)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">OSPF, OSPFv3, IS-IS, IS-ISv6, BGP and BGP4+ (supported by the S5700-EI\/S5700-HI series)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"6\">IPv6 features<\/td>\n<td colspan=\"4\">Neighbor Discovery (ND)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Path MTU (PMTU)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">IPv6 ping, IPv6 tracert, and IPv6 Telnet<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">MLD v1\/v2 snooping<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">6to4 tunnel, ISATAP tunnel, and manually configured tunnel(supported by the S5700-SI\/S5700-EI\/S5700-HI series)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"6\">Multicast<\/td>\n<td colspan=\"4\">IGMP v1\/v2\/v3 snooping and IGMP fast leave<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Multicast forwarding in a VLAN and multicast replication between VLANs<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Multicast load balancing among member ports of a trunk<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Controllable multicast<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Port-based multicast traffic statistics<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">IGMP v1\/v2\/v3, PIM-SM, PIM-DM, PIM-SSM, MSDP (supported by the S5700-EI\/S5700-HI series)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"9\">QoS\/ACL<\/td>\n<td colspan=\"4\">Rate limiting on packets sent and received by an interface<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Packet redirection<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Port-based traffic policing and two-rate three-color CAR<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Eight queues on each port<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">WRR, DRR, SP, WRR+SP, and DRR+SP queue scheduling algorithms<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">WRED (supported by the S5710-EI and S5700-HI)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Re-marking of the 802.1p priority and DSCP priority<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Packet filtering at Layers 2 through 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP\/UDP port number, protocol type, and VLAN ID<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Rate limiting in each queue and traffic shaping on ports<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"13\">Security<\/td>\n<td colspan=\"4\">User privilege management and password protection<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">DoS attack defense, ARP attack defense, and ICMP attack defense<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Binding of the IP address, MAC address, interface, and VLAN<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Port isolation, port security, and sticky MAC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">MFF<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Blackhole MAC address entries<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Limit on the number of learned MAC addresses<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">802.1x authentication and limit on the number of users on an interface<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">SSH v2.0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Hypertext Transfer Protocol Secure (HTTPS)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">CPU defense<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Blacklist and whitelist<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Access Security<\/td>\n<td colspan=\"4\">DHCP Relay, DHCP Server, DHCP Snooping, DHCP Security<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"12\">Management and maintenance<\/td>\n<td colspan=\"4\">Virtual cable test<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Port mirroring and RSPAN (remote port mirroring)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Remote configuration and maintenance using Telnet<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">SNMP v1\/v2c\/v3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">RMON<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Web NMS<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">HGMP<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">System logs and alarms of different levels<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">802.3az EEE (supported by the S5700(S)-LI, S5710-EI, S5700-HI and S5710-HI)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Dying gasp (supported by the S5700-HI, S5710-HI and S5700(S)-LI(except battery LAN\u00a0switches)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">NetStream (supported by the S5710-EI, S5700-HI and S5710-HI)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">sFlow(supported by the S5700(S)-LI\/S5700-EI\/S5700-HI series)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"3\">Interoperability<\/td>\n<td colspan=\"4\" valign=\"top\">Supports VBST (Compatible with PVST\/PVST+\/RPVST)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" valign=\"top\">Supports LNP (Similar to DTP)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" valign=\"top\">Supports VCMP (Similar to VTP)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">Operating environment<\/td>\n<td colspan=\"4\">Operating temperature: 0\u00e2\u201e\u0192\u201350\u00e2\u201e\u0192<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Relative humidity: 10%\u201390% (non-condensing)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"7\">Input voltage<\/td>\n<td colspan=\"4\">AC:<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Rated voltage range: 100 V to 240 V AC, 50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Maximum voltage range: 90 V to 264 V AC, 47\/63 Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">DC:<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Rated voltage range: \u201348 V to \u201360 V, DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Maximum voltage range: \u201336 V to \u201372 V DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Note: PoE-support\u00a0switches\u00a0do not use DC power supplies.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"6\">Dimensions (W x D x H)<\/td>\n<td colspan=\"4\">S5700-10P-LI-AC:250 x 180 x 43.6 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5700-10P-PWR-LI-AC:320 x 220 x 43.6 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5700-28P-LI\/S5700-28TP-LI-AC\/S5700-28X-LI\/S5700-28X-LI-24S\/S5700-24TP-SI\/S5700-28C-HI\/S5700-28C-HI-24S\/ S5701-28X-LI-AC\/ S5701-28X-LI-24S-AC\/ S5700-52X-LI-48CS-AC: 442 x 220 x 43.6 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5700-28P-PWR-LI\/S5700-28TP-PWR-LI-AC\/S5701-28TP-PWR-LI-AC\/S5700-52P-LI\/S5700-52P-PWR-LI\/S5700-28X-PWR-LI-AC\/S5700-52X-LI\/S5700-52X-PWR-LI-AC\/ S5700-26X-SI-12S-AC\/S5700-28P-LI-BAT\/S5700-28P-LI-4AH\/S5700-28P-LI-24S-BAT\/S5700-28P-LI-24S-4AH: 442 x 310 x 43.6 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5710-108C-PWR-HI: 442&#215;470.0x87.2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Others: 442 x 420 x 43.6 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"29\">Powerconsumption<\/td>\n<td colspan=\"4\">S5700-10P-LI-AC&lt;11.5W<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">S5700-10P-PWR-LI-AC&lt;139W<\/td>\n<\/tr>\n<tr>\n<td>S5700-28P-LI&lt;25W<\/td>\n<td>S5700-24TP-SI&lt;40W<\/td>\n<td>S5700-28C-EI&lt;60W<\/td>\n<td>S5700-28C-HI&lt;76W<\/td>\n<\/tr>\n<tr>\n<td>S5700S-28P-LI&lt;25W<\/td>\n<td>S5700-26X-SI-12S-AC&lt;42.3W<\/td>\n<td>S5700-28C-EI-24S&lt;63W<\/td>\n<td>S5700-28C-HI-24S&lt;80W<\/td>\n<\/tr>\n<tr>\n<td>S5700-28TP-LI-AC&lt;26.4W<\/td>\n<td>S5700-48TP-SI&lt;64W<\/td>\n<td>S5700-52C-EI&lt;88W<\/td>\n<td rowspan=\"2\">S5710-108C-PWR-HI&lt;1680W (PoE:1440W)<\/td>\n<\/tr>\n<tr>\n<td>S5700-28TP-PWR-LI-AC&lt;469.7W(PoE:370W)<\/td>\n<td>S5700-28C-SI&lt;56W<\/td>\n<td>S5710-28C-EI&lt;100W<\/td>\n<\/tr>\n<tr>\n<td>S5701-28TP-PWR-LI-AC&lt;238.7W(PoE:185W)<\/td>\n<td>S5700-52C-SI&lt;78W<\/td>\n<td>S5710-52C-EI&lt;165W<\/td>\n<td>S5720-32C-HI-24S-AC&lt;172.7W<\/td>\n<\/tr>\n<tr>\n<td>S5700-52P-LI&lt;52W<\/td>\n<td>S5700-24TP-PWR-SI&lt;455W(PoE: 370W)<\/td>\n<td rowspan=\"2\">S5700-28C-PWR-EI&lt;842W (PoE: 740W)<\/td>\n<td>S5720-56C-HI-AC&lt;183.3W<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">S5700S-52P-LI&lt;52W<\/td>\n<td rowspan=\"2\">S5700-48TP-PWR-SI&lt;907W (PoE: 740W)<\/td>\n<td>S5720-56C-PWR-HI-AC:<br \/>\nwithout PD: &lt;188.74W,<br \/>\nwith PD: &lt;1739W(device:<br \/>\n299W, PD: 1440W)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">S5700-52C-PWR-EI&lt;930W (PoE: 740W)<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">S5700-28P-PWR-LI&lt;436.5W (PoE: 370W)<\/td>\n<td rowspan=\"2\" valign=\"top\"><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>S5710-28C-PWR-EI-AC&lt;942W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>S5710-52C-PWR-EI\/S5710-52C-PWR-EI-AC: &lt; 1043W with two 580W AC supplies(PoE:740W), or &lt;1625W with two 1150W AC supplies(PoE:1440W)<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>S5720-32P-EI-AC &lt;50.7W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>S5720-52P-EI-AC &lt;60.3W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">S5700-52P-PWR-LI&lt;464.5W (PoE: 370W)<\/td>\n<td><\/td>\n<td>S5720-36C-EI-AC &lt;75.8W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>S5720-36C-PWR-EI-AC :<br \/>\nwithout PD: &lt;78W,<br \/>\nwith PD: &lt;864.3W(PoE:740W)<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>S5720-36PC-EI-AC&lt;74.6W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>S5720-36C-EI-28S-AC&lt;83.9W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>S5700-28X-LI&lt;42W<\/td>\n<td><\/td>\n<td>S5720-56C-EI-AC&lt;86.9W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>S5700-28X-LI-24S&lt;54W<\/td>\n<td><\/td>\n<td>S5720-56C-PWR-EI-AC:<br \/>\nwithout PD: &lt;91.6W,<br \/>\nwith PD:&lt;889.4W(PoE:740W)<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>S5700-28X-PWR-LI-AC &lt;448.8W (PoE: 370W)<\/td>\n<td><\/td>\n<td>S5720-56C-PWR-EI-AC1:<br \/>\nwithout PD: &lt;91.6W,<br \/>\nwith PD:&lt;1564.8W(PoE:1440W)<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>S5700-52X-LI&lt;61W<\/td>\n<td><\/td>\n<td>S5720-56PC-EI-AC&lt;85.7W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>S5700-52X-PWR-LI-AC &lt;479.3W (PoE: 370W)<\/td>\n<td><\/td>\n<td valign=\"top\">S5720-56C-EI-48S-AC&lt;104W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>S5700-28P-LI-BAT\/S5700-28P-LI-4AH&lt;23W<\/td>\n<td><\/td>\n<td valign=\"top\">S5720-32X-EI-AC &lt;51.9W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>S5700-28P-LI-24S-BAT\/S5700-28P-LI-24S-4AH&lt;34.1W<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">S5720-32X-EI-24S-AC&lt;58.9W<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td>S5700-52X-LI-48CS-AC&lt;79.9W<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">S5720-50X-EI-AC&lt;55.3W<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td>S5701-28X-LI-AC &lt;39.5W<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">S5720-50X-EI-46S-AC&lt;81.5W<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td>S5701-28X-LI-24S-AC&lt;60W<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">S5720-52X-EI-AC &lt;61.5W<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>&lt; tbody &gt;<\/p>\n<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>S5700-52C-PWR-EI-AC Huawei S5700 Series Switch<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>S5700-52C-PWR-EI-AC(48 Ethernet 10\/100\/1000 PoE+ ports,with 1 interface slot,with 500W AC power supply)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":62297,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[1450],"product_tag":[],"class_list":{"0":"post-34177","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-huawei-switches-huawei-s5700-series-switches-huawei","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/34177","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=34177"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/62297"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=34177"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=34177"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=34177"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=34177"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}