{"id":27186,"date":"2025-09-29T13:22:25","date_gmt":"2025-09-29T13:22:25","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=27186"},"modified":"2025-09-29T13:22:25","modified_gmt":"2025-09-29T13:22:25","slug":"j9310a-2","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/j9310a-2\/","title":{"rendered":"J9310A"},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<h3><strong>J9310A Specifications<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Type<\/p>\n<\/td>\n<td>\n<p>HP 3500-24G-PoE+ yl Switch<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>System specifications<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>I\/O ports and slots<\/p>\n<\/td>\n<td>\n<p>&middot; 20 autosensing 10\/100\/1000 ports; Media Type: Auto-MDIX; Duplex: 10BASE-T\/100BASE-TX: half or full; 1000BASE-T: full only (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T)<\/p>\n<p>&middot; 1 RJ-45 serial console port<\/p>\n<p>&middot; 4 dual-personality ports; each port can be used as either an RJ-45 10\/100\/1000 port (IEEE 802.3 Type 10BASE-T; IEEE 802.3u Type 100BASE-TX; IEEE 802.3ab 1000BASE-T Gigabit Ethernet) with PoE or an open mini-GBIC slot (for use with mini-GBIC transceivers)<\/p>\n<p>&middot; 1 open module slot<\/p>\n<p>&middot; Supports a maximum of 4 10-GbE ports<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Memory and processor Module<\/p>\n<\/td>\n<td>\n<p>10G module:ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM<\/p>\n<p>Management Module: Stackable memory and processor: Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Mounting and enclosure<\/p>\n<\/td>\n<td>\n<p>Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Management<\/p>\n<\/td>\n<td>\n<p>HP PCM+; HP PCM (included); command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Performance<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1000 Mb Latency<\/p>\n<\/td>\n<td>\n<p>&lt; 3.4 &micro;s (FIFO 64-byte packets)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 Gbps Latency<\/p>\n<\/td>\n<td>\n<p>&lt; 2.1 &micro;s (FIFO 64-byte packets)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Throughput<\/p>\n<\/td>\n<td>\n<p>up to 75.7 Mp\/s<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Routing\/Switching capacity<\/p>\n<\/td>\n<td>\n<p>101.8 Gb\/s<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Switch fabric speed<\/p>\n<\/td>\n<td>\n<p>105.6 Gb\/s<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Routing table size<\/p>\n<\/td>\n<td>\n<p>10000 entries (IPv4)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>MAC address table size<\/p>\n<\/td>\n<td>\n<p>64000 entries<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Physical specifications<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Dimensions (H x W x D)<\/p>\n<\/td>\n<td>\n<p>4.4 x 44.3 x 39.2 cm (1.73 x 17.44 x 15.43 in)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Weight<\/p>\n<\/td>\n<td>\n<p>6.29 kg (13.86 lb)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Electrical specifications<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Frequency<\/p>\n<\/td>\n<td>\n<p>50 \/ 60 Hz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Description<\/p>\n<\/td>\n<td>\n<p>The switch automatically adjusts to any voltage between 100-127 and 200-240 V with either 50 or 60 Hz.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum heat dissipation<\/p>\n<\/td>\n<td>\n<p>865 BTU\/hr (912.9 kJ\/hr)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>AC voltage<\/p>\n<\/td>\n<td>\n<p>100-127\/200-240 V ac<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Current<\/p>\n<\/td>\n<td>\n<p>6.6 \/ 3.0 A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Idle power<\/p>\n<\/td>\n<td>\n<p>94W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum power rating<\/p>\n<\/td>\n<td>\n<p>616W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PoE power<\/p>\n<\/td>\n<td>\n<p>398 W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Environmental specifications<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating temperature<\/p>\n<\/td>\n<td>\n<p>0&deg;C to 55&deg;C (32&deg;F to 131&deg;F); 40&deg;C (32&deg;F to 104&deg;F) when used with any X2 10-GbE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating relative humidity<\/p>\n<\/td>\n<td>\n<p>40&deg;C (15% to 95% @ 104&deg;F) noncondensing<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Nonoperating\/Storage temperature<\/p>\n<\/td>\n<td>\n<p>-40&deg;C to 70&deg;C (-40&deg;F to 158&deg;F)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Nonoperating\/Storage relative humidity<\/p>\n<\/td>\n<td>\n<p>65&deg;C (15% to 90% @ 149&deg;F) noncondensing<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Altitude<\/p>\n<\/td>\n<td>\n<p>4.6 km (up to 15,000 ft)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Acoustic<\/p>\n<\/td>\n<td>\n<p>Power: 57.0 dB, Pressure: 40.5 dB ISO 7779, ISO 9296<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Safety agency certifications and emissions<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Safety<\/p>\n<\/td>\n<td>\n<p>CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Emissions<\/p>\n<\/td>\n<td>\n<p>FCC Class A; VCCI Class A; EN 55022\/CISPR 22 Class A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Immunity<\/p>\n<\/td>\n<td>\n<p>EN: EN 55024, CISPR 24<\/p>\n<p>ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD<\/p>\n<p>Radiated: IEC 61000-4-3; 3 V\/m<\/p>\n<p>EFT\/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)<\/p>\n<p>Surge: IEC 61000-4-5; 1 kV\/2 kV AC<\/p>\n<p>Conducted: IEC 61000-4-6; 3 V<\/p>\n<p>Power frequency magnetic field: IEC 61000-4-8; 1 A\/m, 50 or 60 Hz<\/p>\n<p>Voltage dips and interruptions: IEC 61000-4-11; &gt;95% reduction, 0.5 period; 30% reduction, 25 periods<\/p>\n<p>Harmonics: EN 61000-3-2, IEC 61000-3-2<\/p>\n<p>Flicker: EN 61000-3-3, IEC 61000-3-3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Standards and protocols<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>BGP<\/p>\n<\/td>\n<td>\n<p>RFC 1997 &#8211; BGP Communities Attribute<\/p>\n<p>RFC 2918 &#8211; Route Refresh Capability<\/p>\n<p>RFC 4271 &#8211; A Border Gateway Protocol 4 (BGP-4)<\/p>\n<p>RFC 4456 &#8211; BGP Route Reflection: An Alternative to Full Mesh Internal BGP (IBGP)<\/p>\n<p>RFC 5492 &#8211; Capabilities Advertisement with BGP-4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Device management<\/p>\n<\/td>\n<td>\n<p>RFC 1591 &#8211; DNS (client)<\/p>\n<p>HTML and telnet management<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>General protocols<\/p>\n<\/td>\n<td>\n<p>IEEE 802.1ad Q-in-Q<\/p>\n<p>IEEE 802.1AX-2008 Link Aggregation<\/p>\n<p>IEEE 802.1D MAC Bridges<\/p>\n<p>IEEE 802.1p Priority<\/p>\n<p>IEEE 802.1Q VLANs<\/p>\n<p>IEEE 802.1s Multiple Spanning Trees<\/p>\n<p>IEEE 802.1v VLAN classification by Protocol and Port<\/p>\n<p>IEEE 802.1w Rapid Reconfiguration of Spanning Tree<\/p>\n<p>IEEE 802.3ad Link Aggregation Control Protocol (LACP)<\/p>\n<p>IEEE 802.3af Power over Ethernet<\/p>\n<p>IEEE 802.3x Flow Control<\/p>\n<p>RFC 768 &#8211; UDP<\/p>\n<p>RFC 783 &#8211; TFTP Protocol (revision 2)<\/p>\n<p>RFC 792 &#8211; ICMP<\/p>\n<p>RFC 793 &#8211; TCP<\/p>\n<p>RFC 826 &#8211; ARP<\/p>\n<p>RFC 854 &#8211; TELNET<\/p>\n<p>RFC 868 &#8211; Time Protocol<\/p>\n<p>RFC 951 &#8211; BOOTP<\/p>\n<p>RFC 1058 &#8211; RIPv1<\/p>\n<p>RFC 1350 &#8211; TFTP Protocol (revision 2)<\/p>\n<p>RFC 1519 &#8211; CIDR<\/p>\n<p>RFC 1542 &#8211; BOOTP Extensions<\/p>\n<p>RFC 2030 &#8211; Simple Network Time Protocol (SNTP) v4<\/p>\n<p>RFC 2131 &#8211; DHCP<\/p>\n<p>RFC 2453 &#8211; RIPv2<\/p>\n<p>RFC 2548 &#8211; (MS-RAS-Vendor only)<\/p>\n<p>RFC 3046 &#8211; DHCP Relay Agent Information Option<\/p>\n<p>RFC 3576 &#8211; Ext to RADIUS (CoA only)<\/p>\n<p>RFC 3768 &#8211; VRRP<\/p>\n<p>RFC 4675 &#8211; RADIUS VLAN &amp; Priority<\/p>\n<p>UDLD (Uni-directional Link Detection)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>IP multicast<\/p>\n<\/td>\n<td>\n<p>RFC 3376 &#8211; IGMPv3 (host joins only)<\/p>\n<p>RFC 3973 &#8211; Draft 2 PIM Dense Mode<\/p>\n<p>RFC 4601 &#8211; Draft 10 PIM Sparse Mode<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>IPv6<\/p>\n<\/td>\n<td>\n<p>RFC 1981 &#8211; IPv6 Path MTU Discovery<\/p>\n<p>RFC 2375 &#8211; IPv6 Multicast Address Assignments<\/p>\n<p>RFC 2460 &#8211; IPv6 Specification<\/p>\n<p>RFC 2464 &#8211; Transmission of IPv6 over Ethernet Networks<\/p>\n<p>RFC 2710 &#8211; Multicast Listener Discovery (MLD) for IPv6<\/p>\n<p>RFC 2925 &#8211; Definitions of Managed Objects for Remote Ping, Traceroute, and Lookup Operations (Ping only)<\/p>\n<p>RFC 3019 &#8211; MLDv1 MIB<\/p>\n<p>RFC 3315 &#8211; DHCPv6 (client and relay)<\/p>\n<p>RFC 3484 &#8211; Default Address Selection for IPv6<\/p>\n<p>RFC 3587 &#8211; IPv6 Global Unicast Address Format<\/p>\n<p>RFC 3596 &#8211; DNS Extension for IPv6<\/p>\n<p>RFC 3810 &#8211; MLDv2 for IPv6<\/p>\n<p>RFC 4022 &#8211; MIB for TCP<\/p>\n<p>RFC 4087 &#8211; IP Tunnel MIB<\/p>\n<p>RFC 4113 &#8211; MIB for UDP<\/p>\n<p>RFC 4213 &#8211; Basic Transition Mechanisms for IPv6 Hosts and Routers<\/p>\n<p>RFC 4251 &#8211; SSHv6 Architecture<\/p>\n<p>RFC 4252 &#8211; SSHv6 Authentication<\/p>\n<p>RFC 4253 &#8211; SSHv6 Transport Layer<\/p>\n<p>RFC 4254 &#8211; SSHv6 Connection<\/p>\n<p>RFC 4291 &#8211; IP Version 6 Addressing Architecture<\/p>\n<p>RFC 4293 &#8211; MIB for IP<\/p>\n<p>RFC 4294 &#8211; IPv6 Node Requirements<\/p>\n<p>RFC 4419 &#8211; Key Exchange for SSH<\/p>\n<p>RFC 4443 &#8211; ICMPv6<\/p>\n<p>RFC 4541 &#8211; IGMP &amp; MLD Snooping Switch<\/p>\n<p>RFC 4861 &#8211; IPv6 Neighbor Discovery<\/p>\n<p>RFC 4862 &#8211; IPv6 Stateless Address Autoconfiguration<\/p>\n<p>RFC 5095 &#8211; Deprecation of Type 0 Routing Headers in IPv6<\/p>\n<p>RFC 5340 &#8211; OSPFv3 for IPv6<\/p>\n<p>RFC 5453 &#8211; Reserved IPv6 Interface Identifiers<\/p>\n<p>RFC 5519 &#8211; Multicast Group Membership Discovery MIB (MLDv2 only)<\/p>\n<p>RFC 5722 &#8211; Handling of Overlapping IPv6 Fragments<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>MIBs<\/p>\n<\/td>\n<td>\n<p>RFC 1213 &#8211; MIB II<\/p>\n<p>RFC 1493 &#8211; Bridge MIB<\/p>\n<p>RFC 1724 &#8211; RIPv2 MIB<\/p>\n<p>RFC 1850 &#8211; OSPFv2 MIB<\/p>\n<p>RFC 2021 &#8211; RMONv2 MIB<\/p>\n<p>RFC 2096 &#8211; IP Forwarding Table MIB<\/p>\n<p>RFC 2613 &#8211; SMON MIB<\/p>\n<p>RFC 2618 &#8211; RADIUS Client MIB<\/p>\n<p>RFC 2620 &#8211; RADIUS Accounting MIB<\/p>\n<p>RFC 2665 &#8211; Ethernet-Like-MIB<\/p>\n<p>RFC 2668 &#8211; 802.3 MAU MIB<\/p>\n<p>RFC 2674 &#8211; 802.1p and IEEE 802.1Q Bridge MIB<\/p>\n<p>RFC 2737 &#8211; Entity MIB (Version 2)<\/p>\n<p>RFC 2787 &#8211; VRRP MIB<\/p>\n<p>RFC 2863 &#8211; The Interfaces Group MIB<\/p>\n<p>RFC 2925 &#8211; Ping MIB<\/p>\n<p>RFC 2933 &#8211; IGMP MIB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Network management<\/p>\n<\/td>\n<td>\n<p>IEEE 802.1AB Link Layer Discovery Protocol (LLDP)<\/p>\n<p>RFC 2819 &#8211; Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)<\/p>\n<p>RFC 3176 &#8211; sFlow<\/p>\n<p>ANSI\/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)<\/p>\n<p>SNMPv1\/v2c\/v3<\/p>\n<p>XRMON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>OSPF<\/p>\n<\/td>\n<td>\n<p>RFC 2328 &#8211; OSPFv2<\/p>\n<p>RFC 3101 &#8211; OSPF NSSA<\/p>\n<p>RFC 5340 &#8211; OSPFv3 for IPv6<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>QoS\/CoS<\/p>\n<\/td>\n<td>\n<p>RFC 2474 &#8211; DiffServ Precedence, including 8 queues\/port<\/p>\n<p>RFC 2597 &#8211; DiffServ Assured Forwarding (AF)<\/p>\n<p>RFC 2598 &#8211; DiffServ Expedited Forwarding (EF)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Security<\/p>\n<\/td>\n<td>\n<p>IEEE 802.1X Port Based Network Access Control<\/p>\n<p>RFC 1492 &#8211; TACACS+<\/p>\n<p>RFC 2865 &#8211; RADIUS (client only)<\/p>\n<p>RFC 2866 &#8211; RADIUS Accounting<\/p>\n<p>RFC 3579 &#8211; RADIUS Support For Extensible Authentication Protocol (EAP)<\/p>\n<p>Secure Sockets Layer (SSL)<\/p>\n<p>SSHv2 Secure Shell<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<table>< tbody > <\/p>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>J9310A &#8211; HP 3500 and 3500 yl Switch<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td itemprop=\"description\">HP 3500-24G-PoE+ yl Switch<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":60370,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[1163],"product_tag":[],"class_list":{"0":"post-27186","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hpe-switches-hpe-3500-and-3500-yl-switches-hpe","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/27186","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=27186"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/60370"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=27186"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=27186"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=27186"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=27186"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}