{"id":27095,"date":"2025-09-29T13:22:10","date_gmt":"2025-09-29T13:22:10","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=27095"},"modified":"2026-02-07T09:17:09","modified_gmt":"2026-02-07T09:17:09","slug":"j9575a","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/j9575a\/","title":{"rendered":"J9575A"},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<h3><strong>J9575A Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Type<\/p>\n<\/td>\n<td>\n<p>Aruba 3800 24G 2SFP+ Switch<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Physical specifications<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Dimensions (D X W X H)<\/p>\n<\/td>\n<td>\n<p>46.74 x 44.27 x 4.32 cm (18.4 x 17.43 x 1.7 in) (1U height)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Weight<\/p>\n<\/td>\n<td>\n<p>6.92 kg (15.26 lb)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Technical specifications<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Fan tray<\/p>\n<\/td>\n<td>\n<p>1 x J9582A<\/p>\n<p>1 fan tray slot<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Memory and processor<\/p>\n<\/td>\n<td>\n<p>HPE ProVision ASIC\/ARM @ 350 MhzHP ProVision ASIC\/ARM @ 350 Mhz<\/p>\n<p>Freescale PowerPC @ 1200 MHz, 4 GB flash, 2 GB SDRAM<\/p>\n<p>Packet buffer size: 18MB dynamic<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Ports<\/p>\n<\/td>\n<td>\n<p>24 RJ-45 autosensing 10\/100\/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T, IEEE 802.3at PoE+)<\/p>\n<p>Duplex: 10BASE-T\/100BASE-TX: half or full<\/p>\n<p>1000BASE-T: full only<\/p>\n<p>2 fixed 1000\/10000 SFP+ ports<\/p>\n<p>1 RJ-45 serial console port<\/p>\n<p>1 RJ-45 out-of-band management port<\/p>\n<p>1 Stacking module slot<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Electrical specifications<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Power supplies (2 power supply slots 1 minimum power supply required includes)<\/p>\n<\/td>\n<td>\n<p>1 x J9581A (HP X311 400 W 100-240 V ac to 12 V dc power supply)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum heat dissipation<\/p>\n<\/td>\n<td>\n<p>434 BTU\/hr (457.87 kJ\/hr)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Voltage<\/p>\n<\/td>\n<td>\n<p>100-127\/200-240 V ac<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Current<\/p>\n<\/td>\n<td>\n<p>6\/3 A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Idle power<\/p>\n<\/td>\n<td>\n<p>66 W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum power rating<\/p>\n<\/td>\n<td>\n<p>127 W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PoE power<\/p>\n<\/td>\n<td>\n<p>&#8211;<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Frequency<\/p>\n<\/td>\n<td>\n<p>50\/60 Hz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Environmental specifications<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating temperature<\/p>\n<\/td>\n<td>\n<p>0&deg; to 55&deg;C (32&deg; to 131&deg;F); Max temperature is 45&deg;C when tranceivers are installed.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating relative humidity<\/p>\n<\/td>\n<td>\n<p>15% to 95% @ 40&deg;C (104&deg;F), noncondensing<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Nonoperating\/Storage temperature<\/p>\n<\/td>\n<td>\n<p>-40&deg; to 70&deg;C (-40&deg; to 158&deg;F)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Nonoperating\/Storage relative humidity<\/p>\n<\/td>\n<td>\n<p>15% to 90% @ 65&deg;C (149&deg;F), noncondensing<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Altitude<\/p>\n<\/td>\n<td>\n<p>Up to 3 km (10,000 ft)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Acoustic<\/p>\n<\/td>\n<td>\n<p>Power: 36 dB, Pressure: 26.4 dB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Performance specifications<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1000Mb latency<\/p>\n<\/td>\n<td>\n<p>&lt;2.8 &mu;s (LIFO 64-byte packets)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 Gb\/s latency<\/p>\n<\/td>\n<td>\n<p>&lt;1.9 &mu;s (LIFO 64-byte packets)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Throughput (64-byte packets)<\/p>\n<\/td>\n<td>\n<p>65.4 million packets per sec<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Switching capacity<\/p>\n<\/td>\n<td>\n<p>88 Gb\/s<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Routing table size<\/p>\n<\/td>\n<td>\n<p>10000 entries<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>MAC address table size<\/p>\n<\/td>\n<td>\n<p>65500 entries<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Immunity specifications<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>EN<\/p>\n<\/td>\n<td>\n<p>EN 55024, CISPR 24<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ESD<\/p>\n<\/td>\n<td>\n<p>IEC 61000-4-2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Radiated<\/p>\n<\/td>\n<td>\n<p>IEC 61000-4-3; 3 V\/m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>EFT\/Burst<\/p>\n<\/td>\n<td>\n<p>IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Surge<\/p>\n<\/td>\n<td>\n<p>IEC 61000-4-5; 1 or 2 kV ac<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conducted<\/p>\n<\/td>\n<td>\n<p>IEC 61000-4-6; 3 V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Power frequency magnetic field<\/p>\n<\/td>\n<td>\n<p>IEC 61000-4-8; 1 A\/m, 50 or 60 Hz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Voltage dips and interruptions<\/p>\n<\/td>\n<td>\n<p>IEC 61000-4-11; &gt;95% reductions, 0.5 period; 30% reduction, 25 periods<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Harmonics<\/p>\n<\/td>\n<td>\n<p>EN 61000-3-2, IEC 61000-3-2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Flicker<\/p>\n<\/td>\n<td>\n<p>EN 61000-3-3, IEC 61000-3-3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Safety certifications<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Safety<\/p>\n<\/td>\n<td>\n<p>EN 60950\/IEC 60950; UL 60950; CAN\/CSA 22.2 No. 60950; EN 60825<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Emissions<\/p>\n<\/td>\n<td>\n<p>FCC Class A; VCCI Class A; EN 55022\/CISPR 22 Class A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" colspan=\"2\">\n<p><strong>Standards and protocols<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Device management<\/p>\n<\/td>\n<td>\n<p>RFC 1591 DNS (client)<\/p>\n<p>RFC 2576 (Coexistence between SNMP V1, V2, V3)<\/p>\n<p>RFC 2579 (SMIv2 Text Conventions)<\/p>\n<p>RFC 2580 (SMIv2 Conformance)<\/p>\n<p>RFC 3416 (SNMP Protocol Operations v2)<\/p>\n<p>RFC 3417 (SNMP Transport Mappings)<\/p>\n<p>HTML and telnet management<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>General protocols<\/p>\n<\/td>\n<td>\n<p>IEEE 802.1ad Q-in-Q<\/p>\n<p>IEEE 802.1AX-2008 Link Aggregation<\/p>\n<p>IEEE 802.1D MAC Bridges<\/p>\n<p>IEEE 802.1p Priority<\/p>\n<p>IEEE 802.1Q VLANs<\/p>\n<p>IEEE 802.1s Multiple Spanning Trees<\/p>\n<p>IEEE 802.1v VLAN classification by Protocol and Port<\/p>\n<p>IEEE 802.1w Rapid Reconfiguration of Spanning Tree<\/p>\n<p>IEEE 802.3ad Link Aggregation Control Protocol (LACP)<\/p>\n<p>IEEE 802.3af Power over Ethernet<\/p>\n<p>IEEE 802.3x Flow Control<\/p>\n<p>RFC 768 UDP<\/p>\n<p>RFC 783 TFTP Protocol (revision 2)<\/p>\n<p>RFC 792 ICMP<\/p>\n<p>RFC 793 TCP<\/p>\n<p>RFC 826 ARP<\/p>\n<p>RFC 854 TELNET<\/p>\n<p>RFC 868 Time Protocol<\/p>\n<p>RFC 951 BOOTP<\/p>\n<p>RFC 1058 RIPv1<\/p>\n<p>RFC 1350 TFTP Protocol (revision 2)<\/p>\n<p>RFC 1519 CIDR<\/p>\n<p>RFC 1542 BOOTP Extensions<\/p>\n<p>RFC 2030 Simple Network Time Protocol (SNTP) v4<\/p>\n<p>RFC 2131 DHCP<\/p>\n<p>RFC 2453 RIPv2<\/p>\n<p>RFC 2548 (MS-RAS-Vendor only)<\/p>\n<p>RFC 3046 DHCP Relay Agent Information Option<\/p>\n<p>RFC 3575 IANA Considerations for RADIUS<\/p>\n<p>RFC 3576 Ext to RADIUS (CoA only)<\/p>\n<p>RFC 3768 VRRP<\/p>\n<p>RFC 4675 RADIUS VLAN &amp; Priority<\/p>\n<p>RFC 3768 VRRP<\/p>\n<p>RFC 4675 RADIUS VLAN &amp; Priority<\/p>\n<p>RFC 5798 VRRP (exclude Accept Mode and sub-sec timer)<\/p>\n<p>RFC 5905 Network Time Protocol Version 4: Protocol and Algorithms Specification<\/p>\n<p>UDLD (Uni-directional Link Detection)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>IP multicast<\/p>\n<\/td>\n<td>\n<p>RFC 3376 IGMPv3 (host joins only)<\/p>\n<p>RFC 3973 Draft 2 PIM Dense Mode<\/p>\n<p>RFC 4601 Draft 10 PIM Sparse Mode<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>IPv6<\/p>\n<\/td>\n<td>\n<p>RFC 1981 IPv6 Path MTU Discovery<\/p>\n<p>RFC 2080 RIPng for IPv6<\/p>\n<p>RFC 2081 RIPng Protocol Applicability Statement<\/p>\n<p>RFC 2082 RIP-2 MD5<\/p>\n<p>RFC 2375 IPv6 Multicast Address Assignments<\/p>\n<p>RFC 2460 IPv6 Specification<\/p>\n<p>RFC 2464 Transmission of IPv6 over Ethernet Networks<\/p>\n<p>RFC 2710 Multicast Listener Discovery (MLD) for IPv6<\/p>\n<p>RFC 2925 Remote Operations MIB (Ping only)<\/p>\n<p>RFC 3019 MLDv1 MIB<\/p>\n<p>RFC 3315 DHCPv6 (client only)<\/p>\n<p>RFC 3484 Default Address Selection for IPv6<\/p>\n<p>RFC 3587 IPv6 Global Unicast Address Format<\/p>\n<p>RFC 3596 DNS Extension for IPv6<\/p>\n<p>RFC 3810 MLDv2 (host joins only)<\/p>\n<p>RFC 4022 MIB for TCP<\/p>\n<p>RFC 4087 IP Tunnel MIB<\/p>\n<p>RFC 4113 MIB for UDP<\/p>\n<p>RFC 4213 Basic Transition Mechanisms for IPv6 Hosts and Routers<\/p>\n<p>RFC 4251 SSHv6 Architecture<\/p>\n<p>RFC 4252 SSHv6 Authentication<\/p>\n<p>RFC 4253 SSHv6 Transport Layer<\/p>\n<p>RFC 4254 SSHv6 Connection<\/p>\n<p>RFC 4291 IP Version 6 Addressing Architecture<\/p>\n<p>RFC 4293 MIB for IP<\/p>\n<p>RFC 4294 IPv6 Node Requirements<\/p>\n<p>RFC 4419 Key Exchange for SSH<\/p>\n<p>RFC 4443 ICMPv6<\/p>\n<p>RFC 4541 IGMP &amp; MLD Snooping Switch<\/p>\n<p>RFC 4861 IPv6 Neighbor Discovery<\/p>\n<p>RFC 4862 IPv6 Stateless Address Auto-configuration<\/p>\n<p>RFC 5095 Deprecation of Type 0 Routing Headers in IPv6<\/p>\n<p>RFC 5340 OSPFv3 for IPv6<\/p>\n<p>RFC 5453 Reserved IPv6 Interface Identifiers<\/p>\n<p>RFC 5519 Multicast Group Membership Discovery MIB (MLDv2 only)<\/p>\n<p>RFC 5722 Handling of Overlapping IPv6 Fragments<\/p>\n<p>RFC 6620 FCFS SAVI<\/p>\n<p>draft-ietf-savi-mix<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>MIBs<\/p>\n<\/td>\n<td>\n<p>IEEE 802.1ap (MSTP and STP MIB&#8217;s only)<\/p>\n<p>IEEE 8021-Bridge-MIB (2008)<\/p>\n<p>IEEE 8021-Q-Bridge-MIB (2008)<\/p>\n<p>RFC 1155 Structure &amp; ID of Mgmt Info for TCP\/IP Internets<\/p>\n<p>RFC 1213 MIB II<\/p>\n<p>RFC 1493 Bridge MIB<\/p>\n<p>RFC 1724 RIPv2 MIB<\/p>\n<p>RFC 1850 OSPFv2 MIB<\/p>\n<p>RFC 2021 RMONv2 MIB<\/p>\n<p>RFC 2096 IP Forwarding Table MIB<\/p>\n<p>RFC 2613 SMON MIB<\/p>\n<p>RFC 2618 RADIUS Client MIB<\/p>\n<p>RFC 2620 RADIUS Accounting MIB<\/p>\n<p>RFC 2665 Ethernet-Like-MIB<\/p>\n<p>RFC 2668 802.3 MAU MIB<\/p>\n<p>RFC 2674 802.1p and IEEE 802.1Q Bridge MIB<\/p>\n<p>RFC 2737 Entity MIB (Version 2)<\/p>\n<p>RFC 2787 VRRP MIB<\/p>\n<p>RFC 2863 The Interfaces Group MIB<\/p>\n<p>RFC 2925 Ping MIB<\/p>\n<p>RFC 2932 IP (Multicast Routing MIB)<\/p>\n<p>RFC 2933 IGMP MIB<\/p>\n<p>RFC 4836 Managed Objects for 802.3 Medium Attachment Units (MAU)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Network management<\/p>\n<\/td>\n<td>\n<p>IEEE 802.1AB Link Layer Discovery Protocol (LLDP)<\/p>\n<p>RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)<\/p>\n<p>RFC 3176 sFlow<\/p>\n<p>RFC 3411 SNMP Management Frameworks<\/p>\n<p>RFC 3412 Message Processing and Dispatching for the Simple Network Management Protocol (SNMP)<\/p>\n<p>RFC 3413 Simple Network Management Protocol (SNMP) Applications<\/p>\n<p>RFC 3414 User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)<\/p>\n<p>RFC 3415 View-based Access Control Model (VACM) for the Simple Network Management Protocol (SNMP)<\/p>\n<p>ANSI\/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)<\/p>\n<p>RFC 3418 Management Information Base (MIB) for the Simple Network Management Protocol (SNMP)<\/p>\n<p>RFC 5424 Syslog Protocol<\/p>\n<p>ANSI\/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)<\/p>\n<p>SNMPv1\/v2c\/v3<\/p>\n<p>XRMON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>OSPF<\/p>\n<\/td>\n<td>\n<p>RFC 2328 OSPFv2<\/p>\n<p>RFC 3101 OSPF NSSA<\/p>\n<p>RFC 3623 Graceful OSPF Restart (Unplanned Outages only)<\/p>\n<p>RFC 5340 OSPFv3 for IPv6<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>QoS\/CoS<\/p>\n<\/td>\n<td>\n<p>RFC 2474 DiffServ Precedence, including 8 queues\/port<\/p>\n<p>RFC 2475 DiffServ Architecture<\/p>\n<p>RFC 2597 DiffServ Assured Forwarding (AF)<\/p>\n<p>RFC 2598 DiffServ Expedited Forwarding (EF)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Security<\/p>\n<\/td>\n<td>\n<p>IEEE 802.1X Port Based Network Access Control<\/p>\n<p>RFC 1321 The MD5 Message-Digest Algorithm<\/p>\n<p>RFC 1492 TACACS+<\/p>\n<p>RFC 2818 HTTP Over TLS<\/p>\n<p>RFC 2865 RADIUS (client only)<\/p>\n<p>RFC 2866 RADIUS Accounting<\/p>\n<p>RFC 3579 RADIUS Support For Extensible Authentication Protocol (EAP)<\/p>\n<p>Access Control Lists (ACLs)<\/p>\n<p>MAC Authentication<\/p>\n<p>MAC Lockdown<\/p>\n<p>MAC Lockout<\/p>\n<p>Port Security<\/p>\n<p>Secure Sockets Layer (SSL)<\/p>\n<p>SSHv1\/SSHv2 Secure Shell<\/p>\n<p>SSHv2 Secure Shell<\/p>\n<p>Web Authentication<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<table>< tbody > <\/p>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>J9575A &#8211; HP 3800 Switch<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td itemprop=\"description\">HP 3800-24G-2SFP+ Switch<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":60405,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[1167],"product_tag":[],"class_list":{"0":"post-27095","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hpe-switches-hpe-3800-switches-hpe","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/27095","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=27095"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/60405"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=27095"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=27095"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=27095"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=27095"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}