{"id":18942,"date":"2025-09-29T12:26:34","date_gmt":"2025-09-29T12:26:34","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=18942"},"modified":"2025-09-29T12:26:34","modified_gmt":"2025-09-29T12:26:34","slug":"c9606r-48y24c-bn-a-3","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/c9606r-48y24c-bn-a-3\/","title":{"rendered":"C9606R-48Y24C-BN-A"},"content":{"rendered":"<h2><span data-sheets-value=\"\"><a href=\"https:\/\/itnetworks.ae\/c9606r-48y24c-bn-a.html\" target=\"_blank\" rel=\"noopener\">c9606r-48y24c-bn-a<\/a> datasheet<\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Buying Cisco <\/span><span style=\"font-weight: 400;\">C9606r-48y24c-bn-a<\/span><span style=\"font-weight: 400;\"> Switches for <\/span><a href=\"https:\/\/gntme.com\/\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400;\">Gear Net Technologies<\/span><\/a><span style=\"font-weight: 400;\"> will be an awesome method to give your office organization, an increase in speed and execution that likewise at an extraordinarily low cost.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The Cisco Catalyst <\/span><span style=\"font-weight: 400;\">C9606r-48y24c-bn-a<\/span><span style=\"font-weight: 400;\"> Switches are the establishment of most business organizations, and how critical they are for your work environment. Through <\/span><a href=\"https:\/\/gntme.com\/product-category\/cisco\/cisco-switches\/\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400;\">Cisco Switches<\/span><\/a><span style=\"font-weight: 400;\">, gadgets associated with your organization can speak with each other and furthermore with different organizations effectively, much the same as the Internet. Cisco conveys a far-reaching arrangement of exchanging answers for Enterprise Networks, server farms, and more modest organizations. These arrangements are improved for a wide scope of enterprises, including specialist co-ops, monetary administrations, and the public area.<\/span><\/p>\n<p><a href=\"https:\/\/gntme.com\/product-category\/cisco\/cisco-switches\/cisco-switch-catalyst-9600\/\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400;\">Cisco Catalyst 9600 Series<\/span><\/a><span style=\"font-weight: 400;\"> switches are reason worked for strength at scale with the business&#8217; most thorough security and permits your business to develop at the least complete operational expense. Based upon the establishment of Catalyst 9000, the Catalyst 9600 Series offers scale &amp; security when consistently on is an unquestionable requirement.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Detail:<\/span> <span style=\"font-weight: 400;\">Catalyst 9600 Series 6 slot bundle,with 1xSup,2xLC,DNA-A LIC<\/span><\/p>\n<p>&nbsp;<\/p>\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"568\">\n<h3 align=\"center\"><strong>C9606R-48Y24C-BN-A<\/strong><strong>\u00a0<\/strong><strong>Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\"><strong>Product Code<\/strong><\/td>\n<td valign=\"top\" width=\"284\">C9606R-48Y24C-BN-A<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\"><strong>Product Description<\/strong><\/td>\n<td valign=\"top\" width=\"284\">Catalyst 9600 Series 6 slot, 1xSup, 2xLC , DNA-A LIC<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\"><strong>Dimensions (H x W x D)<\/strong><\/td>\n<td valign=\"top\" width=\"284\">35.43 x 44.2 x 40.9 cm<\/p>\n<p>13.95 x 17.4 x 16.1 in.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Rack Units (RU)<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Total number of slots<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">6<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Line-card slots<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Supervisor engine slots<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Dedicated supervisor engine slot numbers<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">3 and 4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Supervisor engine redundancy<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Supervisor engines supported<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">C9600-SUP-1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Maximum bandwidth scalability per line-card slot<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">6.4 Tbps<sup>**<\/sup><\/p>\n<p class=\"p\">2.4 Tbps<sup>***<\/sup><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Number of power supply bays<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Minimum number of power supplies<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">2<sup>*<\/sup><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Power supplies supported<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">2000W AC, 2000W DC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Number of fan-tray bays<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"568\">\n<p class=\"p\">*Fully loaded 9606R chassis, Minimum 3 power supplies required if input voltage is 110V<\/p>\n<p class=\"p\">**Hardware ready<\/p>\n<p class=\"p\">***With C9600-SUP-1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Input voltage<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">AC: 90V to 264V, 47 to 63 Hz AC<\/p>\n<p class=\"p\">DC: -40V to -72V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Operating temperature<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">-5<span style=\"font-family: Arial;\">\u00b0 <\/span><span style=\"font-family: Calibri;\">to 45<\/span><span style=\"font-family: Arial;\">\u00b0 <\/span><span style=\"font-family: Calibri;\">C (23<\/span><span style=\"font-family: Arial;\">\u00b0 <\/span><span style=\"font-family: Calibri;\">to 113<\/span><span style=\"font-family: Arial;\">\u00b0 <\/span><span style=\"font-family: Calibri;\">F) up to 6000 feet<\/span><\/p>\n<p class=\"p\">-5<span style=\"font-family: Arial;\">\u00b0 <\/span><span style=\"font-family: Calibri;\">to 40<\/span><span style=\"font-family: Arial;\">\u00b0 <\/span><span style=\"font-family: Calibri;\">C (23<\/span><span style=\"font-family: Arial;\">\u00b0 <\/span><span style=\"font-family: Calibri;\">to 104<\/span><span style=\"font-family: Arial;\">\u00b0 <\/span><span style=\"font-family: Calibri;\">F) up to 10,000 feet<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Storage temperature<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">-40<span style=\"font-family: Arial;\">\u00b0 <\/span><span style=\"font-family: Calibri;\">to 75<\/span><span style=\"font-family: Arial;\">\u00b0 <\/span><span style=\"font-family: Calibri;\">C (40<\/span><span style=\"font-family: Arial;\">\u00b0 <\/span><span style=\"font-family: Calibri;\">to 167<\/span><span style=\"font-family: Arial;\">\u00b0 <\/span><span style=\"font-family: Calibri;\">F)<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Relative humidity, operating and nonoperating, noncondensing<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">10% to 95%, noncondensing<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Altitude<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">-60 to 3000 m (-197 to 9843 feet)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Mean Time Between Failures (MTBF) (hours)<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">C9606R chassis: 4,113,900<\/p>\n<p class=\"p\">C9606 fan tray: 452,570<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Weight of fan tray<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">3.56 kg(7.85 lb)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Weight of individual PSUs<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">AC PSU: 1.2 kg (2.65 lb)<\/p>\n<p class=\"p\">DC PSU: 1.28 kg (2.82 lb)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>Safety certifications<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">C9606R<\/p>\n<p>\u2022IEC 60950-1 plus Am1, Am2, Am9, Am10, Am11, Am12 and all deviations and\u00a0differences<\/p>\n<p>\u2022AS\/NZS 60950.1.2011<\/p>\n<p>\u2022CAN\/CSA-C22.2 No. 60950-1-07<\/p>\n<p>\u2022GB 4943-95<\/p>\n<p>\u2022EN 60950-1; 2006 plus Am1, Am 2, Am9, Am10, Am11, Am12 and all deviations and differences<\/p>\n<p>\u2022NOM-019-SCFI-1998<\/p>\n<p>\u2022UL 60950-1, Second Edition<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\"><strong>EMI and EMC compliance<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"284\">\n<p class=\"p\">47 CFR Part 15 Class A<\/p>\n<p class=\"p\">CNS13438: 2006<span style=\"font-family: Arial;\">\u00a0<\/span><span style=\"font-family: Calibri;\">Class A<\/span><\/p>\n<p class=\"p\">EN 300 386 V1.6.1<\/p>\n<p class=\"p\">EN61000-3-2: 2014<\/p>\n<p class=\"p\">EN61000-3-3: 2013<\/p>\n<p class=\"p\">ICES-003 Issue 6: 2016<span style=\"font-family: Arial;\">\u00a0<\/span><span style=\"font-family: Calibri;\">Class A<\/span><\/p>\n<p class=\"p\">KN 32: 2015<span style=\"font-family: Arial;\">\u00a0<\/span><span style=\"font-family: Calibri;\">Class A<\/span><\/p>\n<p class=\"p\">TCVN 7189: 2009<span style=\"font-family: Arial;\">\u00a0<\/span><span style=\"font-family: Calibri;\">Class A<\/span><\/p>\n<p class=\"p\">EN 55032:2012\/ AC:2013 Class A<\/p>\n<p class=\"p\">EN 55032:2015 Class A<\/p>\n<p class=\"p\">CISPR 32 Edition 2<span style=\"font-family: Arial;\">\u00a0<\/span><span style=\"font-family: Calibri;\">Class A<\/span><\/p>\n<p class=\"p\">V-2\/2015.04<span style=\"font-family: Arial;\">\u00a0<\/span><span style=\"font-family: Calibri;\">Class A<\/span><\/p>\n<p class=\"p\">V-3\/2015.04 Class A<\/p>\n<p class=\"p\">CISPR24: 2010 + A1: 2015<\/p>\n<p class=\"p\">EN 300 386 V1.6.1<\/p>\n<p class=\"p\">EN55024: 2010 + A1: 2015<\/p>\n<p class=\"p\">KN35: 2015<\/p>\n<p class=\"p\">TCVN 7317: 2003<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>C9606R-48Y24C-BN-A &#8211; Cisco Switch Catalyst 9600<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>Catalyst 9600 Series 6 slot bundle,with 1xSup,2xLC,DNA-A LIC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>PDF Attachment:<\/p>\n<p><a href=\"https:\/\/gntme.com\/wp-content\/uploads\/2021\/04\/c9606r-48y24c-bn-a-datasheet-converted.pdf\">c9606r-48y24c-bn-a datasheet<\/a><\/p>","protected":false},"featured_media":54586,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[548],"product_tag":[],"class_list":{"0":"post-18942","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-switches-cisco-switch-catalyst-9600-cisco","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/18942","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=18942"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/54586"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=18942"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=18942"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=18942"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=18942"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}