{"id":18909,"date":"2025-09-29T12:26:11","date_gmt":"2025-09-29T12:26:11","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=18909"},"modified":"2025-09-29T12:26:11","modified_gmt":"2025-09-29T12:26:11","slug":"ie-2000u-16tc-gp-2","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/ie-2000u-16tc-gp-2\/","title":{"rendered":"IE-2000U-16TC-GP"},"content":{"rendered":"<h3><span data-sheets-value=\"\">IE-2000U-16TC-GP datasheet<\/span><\/h3>\n<p><span data-sheets-value=\"\" data-sheets-userformat=\",&quot;12&quot;:0}\">IE-2000U-16TC-GP \u2013 Industrial Ethernet 2000 Series<\/span><\/p>\n<p style=\"text-align: justify;\"><span data-sheets-value=\"\">IE-2000U-16TC-GP datasheet, <\/span>Searching for a Cisco IE-2000U-16TC-GP Switch for productive systems administration at your working environment? Search no more! Our <a href=\"https:\/\/gntme.com\/\" target=\"_blank\" rel=\"noopener\">gntme.com<\/a>\u00a0site gives you the best cisco items that fulfill every one of your necessities.<\/p>\n<p style=\"text-align: justify;\">Switches are the establishment of most business organizations, and how critical they are for your work environment. Through\u00a0<a href=\"https:\/\/gntme.com\/product-category\/cisco\/cisco-switches\/\" target=\"_blank\" rel=\"noopener\">Cisco Switches<\/a>, gadgets associated with your organization can speak with each other and furthermore with different organizations effectively, much the same as the Internet. Cisco conveys a far-reaching arrangement of exchanging answers for Enterprise Networks, server farms, and more modest organizations. These arrangements are improved for a wide scope of enterprises, including specialist co-ops, monetary administrations, and the public area.<\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">The Cisco 2000U Industrial Ethernet Switches (IE 2000U) are a scope of minimal switches intended for the unforgiving, tough conditions frequently found in the energy and utility ventures. IE 2000U switches are intended to help the correspondence foundation needs for the energy conveyance framework across dispersed age, transmission, and appropriation areas. This foundation incorporates utility and client claimed energy framework, for example, substation applications supporting electrical transmission and dispersion, sustainable age, oil and gas, water, circulated age, cogeneration, and trackside tasks. The foundation likewise incorporates a correspondence framework for conveyance applications like transmission pipelines, dissemination mains, and administration lines for oil and gas and water. You can buy related products like <\/span><a href=\"https:\/\/gntme.com\/product\/ie-2000-16ptc-g-e-2\/\" target=\"_blank\" rel=\"noopener\">IE-2000-16PTC-G-E<\/a>, <span style=\"font-size: 1.5rem;\"><a href=\"https:\/\/gntme.com\/product\/ie-2000-16ptc-g-l-2\/\" target=\"_blank\" rel=\"noopener\"><span style=\"font-size: 12px;\">IE-2000-16PTC-G-L<\/span><\/a>.<\/span><\/p>\n<p><b>Main Features:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Switch<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">managed<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">16 x 10\/100 + 2 x combo Gigabit SFP<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">DIN rail mountable <\/span>PoE+<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"568\">\n<h3 align=\"center\"><strong>IE-2000U-16TC-GP Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>Total Ports<\/strong><\/td>\n<td valign=\"top\" width=\"382\">18<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>RJ45 Ports<\/strong><\/td>\n<td valign=\"top\" width=\"382\">16 FE<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>Combo Ports<\/strong><\/td>\n<td valign=\"top\" width=\"382\">2 GE<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>Software<\/strong><\/td>\n<td valign=\"top\" width=\"382\">LAN Base<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>IEEE 1588<\/strong><\/td>\n<td valign=\"top\" width=\"382\">Yes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>PRP<\/strong><\/td>\n<td valign=\"top\" width=\"382\">Yes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>PoE<\/strong><\/td>\n<td valign=\"top\" width=\"382\">Yes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>Hardware<\/strong><\/td>\n<td valign=\"top\" width=\"382\">\u25cf\u00a0\u00a0256 MB DRAM with ECC memory<\/p>\n<p>\u25cf\u00a0\u00a01 GB removable SD flash memory card (CG swap drive) \u2013 (128MB space available)<\/p>\n<p>\u25cf\u00a0\u00a0Mini-USB connector<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>Alarm<\/strong><\/td>\n<td valign=\"top\" width=\"382\">\u25cf\u00a0\u00a0Alarm I\/O: two alarm inputs to detect dry contact open or closed, one alarm output relay. 48 VDC, 0.5A max<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>Power Supply<\/strong><\/td>\n<td valign=\"top\" width=\"382\">\u25cf\u00a0\u00a0Redundant DC input voltage with operating range: 12-48 VDC Nominal, 9.6-60 VDC Maximum<\/p>\n<p>\u25cf\u00a0\u00a0Maximum DC input current: 0.5A at 48 VDC, 1A at 24 VDC<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Substation Compliance<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0IEC 61850-3<\/p>\n<p>\u25cf\u00a0\u00a0IEEE1613<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Hazardous Location<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0ANSI\/ISA 12.12.01 (Class 1, Div 2 A-D) (requires cabinet enclosure)<\/p>\n<p>\u25cf\u00a0\u00a0UL\/CSA 60079-0, -15 (Class 1, Zone 2, group II gases, requires cabinet enclosure)<\/p>\n<p>\u25cf\u00a0\u00a0EN 60079-0, -15 ATEX certification (Class I, Zone 2, Group II gases, requires cabinet enclosure)<\/p>\n<p>\u25cf\u00a0\u00a0IEC 60079-0, -15 (Class I Zone 2, Group II gases, requires cabinet enclosure)<\/p>\n<p>\u25cf\u00a0\u00a0CSA 213<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Industrial Control Safety<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0UL508<\/p>\n<p>\u25cf\u00a0\u00a0CSA C22.2 No. 142<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>EMC Interface Immunity<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0EN 55024 (CISPR 24)<\/p>\n<p>\u25cf\u00a0\u00a0AS\/NZS CISPR 24<\/p>\n<p>\u25cf\u00a0\u00a0KN 24<\/p>\n<p>\u25cf\u00a0\u00a0IEC61000-4-2 (Criteria A &#8211; Class 2)<\/p>\n<p>\u25cf\u00a0\u00a0IEC61000-4-3\/ENV50204 (Criteria A)<\/p>\n<p>\u25cf\u00a0\u00a0IEC61000-4-4 (Criteria A\/Criteria B)<\/p>\n<p>\u25cf\u00a0\u00a0IEC61000-4-5 (Criteria B)<\/p>\n<p>\u25cf\u00a0\u00a0IEC61000-4-6 (Criteria A)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Standard Electromagnetic Emissions Certifications<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0FCC Part 15 Class A<\/p>\n<p>\u25cf\u00a0\u00a0EN 55022 Class A (CISPR22 Class A)<\/p>\n<p>\u25cf\u00a0\u00a0ICES-003 Class A<\/p>\n<p>\u25cf\u00a0\u00a0EN 300 386<\/p>\n<p>\u25cf\u00a0\u00a0VCCI Class A<\/p>\n<p>\u25cf\u00a0\u00a0AS\/NZS CISPR22 Class A<\/p>\n<p>\u25cf\u00a0\u00a0CNS 13438 Class A<\/p>\n<p>\u25cf\u00a0\u00a0KN 22 Class A CE Marking<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Standard Safety Certifications<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0UL 60950-1<\/p>\n<p>\u25cf\u00a0\u00a0CSA 60950-1<\/p>\n<p>\u25cf\u00a0\u00a0EN 60950-1<\/p>\n<p>\u25cf\u00a0\u00a0IEC 60950-1, CB report and certificate with all national differences<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Operating Environment<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0Operating Temperature: -40C to +75C<\/p>\n<p>\u25cf\u00a0\u00a0-40C to +70C (Vented Enclosure \u2013 40 LFM Air Flow)<\/p>\n<p>\u25cf\u00a0\u00a0-40C to +60C (Sealed Enclosure \u2013 0 LFM Air Flow)<\/p>\n<p>\u25cf\u00a0\u00a0-34C to +75C (Fan or Blower equipped Enclosure \u2013 200 LFM Air Flow)<\/p>\n<p>\u25cf\u00a0\u00a0-40 to +85C (IEC 60068-2-2 Environmental Type testing &#8211; 100 hours)<\/p>\n<p>\u25cf\u00a0\u00a0Operating altitude: -60 m (-200 ft) to 3,000 m (10,000 ft), de-rate maximum operating temperature per IEEE 1613-2009:<\/p>\n<p>\u25cf\u00a0\u00a0Relative humidity: 5% to 95% non-condensing<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Storage Environment<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0Temperature: -50\u00ba C to +85\u00ba C<\/p>\n<p>\u25cf\u00a0\u00a0Altitude: 15,100 ft (4600 m)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Warranty<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0Five-year limited warranty on all IE-2000U HW PIDs<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Protection Class Code<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0IP30 per EN60529<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>&lt; tbody &gt;<\/p>\n<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>IE-2000U-16TC-GP &#8211; Industrial Ethernet 2000 Series<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>IE 2000U 16 x 10\/100,2 T\/SFP GE ports with 1588, PoE<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"woocommerce-product-details__short-description\">\n<p>PDF Attachment:<\/p>\n<p><a href=\"https:\/\/gntme.com\/wp-content\/uploads\/2021\/04\/ie-2000u-16tc-gp-datasheet-converted.pdf\">ie-2000u-16tc-gp datasheet<\/a><\/p>\n<p><a href=\"https:\/\/gntme.com\/wp-content\/uploads\/2021\/04\/cisco-industrial-ethernet-2000-series-switches-data-sheet-converted-1.pdf\">cisco industrial ethernet 2000 series switches data sheet<\/a><\/p>\n<\/div>\n<p>&nbsp;<\/p>","protected":false},"featured_media":54560,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[536],"product_tag":[],"class_list":{"0":"post-18909","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-switches-cisco-industrial-ethernet-2000-switches-cisco","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/18909","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=18909"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/54560"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=18909"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=18909"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=18909"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=18909"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}