{"id":18896,"date":"2025-09-29T12:26:01","date_gmt":"2025-09-29T12:26:01","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=18896"},"modified":"2025-09-29T12:26:01","modified_gmt":"2025-09-29T12:26:01","slug":"ie-2000-16t67-b-2","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/ie-2000-16t67-b-2\/","title":{"rendered":"IE-2000-16T67-B"},"content":{"rendered":"<h3><span data-sheets-value=\"\">ie-2000-16t67-b datasheet<\/span><\/h3>\n<p>IE-2000-16T67-B &#8211; Industrial Ethernet 2000 Series<\/p>\n<p style=\"text-align: justify;\"><span data-sheets-value=\"\">ie-2000-16t67-b datasheet, <\/span>Buying\u00a0<strong>Cisco IE-2000-16T67-B Switches<\/strong>\u00a0for\u00a0<a href=\"https:\/\/gntme.com\/\" target=\"_blank\" rel=\"noopener\">GearNetTech<\/a>\u00a0will be an awesome method to give your office organization, an increase in speed and execution that likewise at an extraordinarily low cost.<\/p>\n<p style=\"text-align: justify;\">Switches are the establishment of most business organizations, and how critical they are for your work environment. Through\u00a0<a href=\"https:\/\/gntme.com\/product-category\/cisco\/cisco-switches\/\" target=\"_blank\" rel=\"noopener\">Cisco Switches<\/a>, gadgets associated with your organization can speak with each other and furthermore with different organizations effectively, much the same as the Internet. Cisco conveys a far-reaching arrangement of exchanging answers for Enterprise Networks, server farms, and more modest organizations. These arrangements are improved for a wide scope of enterprises, including specialist co-ops, monetary administrations, and the public area.<\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\"><a href=\"https:\/\/gntme.com\/product-category\/cisco\/cisco-switches\/cisco-industrial-ethernet-2000-switches\/\" target=\"_blank\" rel=\"noopener\">The Cisco Industrial Ethernet (IE) 2000<\/a> IP67 Series is Cisco&#8217;s initially ruggedized exchanging stage that agrees with the most requesting IP67 mechanical guidelines. It likewise gives all that you&#8217;ve generally expected from the worldwide pioneer in Internet Protocol (IP) organizing: simple coordination with the remainder of your organization, dependability, unshakable execution, and top-notch uphold. Presently, those benefits and Cisco IOS Software highlights stretch outright to the manufacturing plant floor, rail yard, or another mechanical site, even in the harshest conditions. So you can at long last satisfy the guarantee of organization intermingling across both data innovation (IT) and tasks innovation (OT) conditions with one provider.<\/span><\/p>\n<p><b>Main Features<\/b> <b>:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Switch<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">managed<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">16 x 10\/100<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\">wall-mountable<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"568\">\n<h3 align=\"center\"><strong>IE-2000-16T67-B Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"124\"><strong>Total Ports<\/strong><\/td>\n<td valign=\"top\" width=\"444\">16<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"124\"><strong>100 MB D-code<\/strong><\/td>\n<td valign=\"top\" width=\"444\">16<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"124\"><strong>Manufacturing license<\/strong><\/td>\n<td valign=\"top\" width=\"444\">LAN Base<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"124\"><strong>Dimensions (H x W x D)<\/strong><\/td>\n<td valign=\"top\" width=\"444\">9.5\u201d x 11.84\u201d x 3.2\u201d (241.7 x 300.7 x 81.5 mm)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"124\"><strong>Weight<\/strong><\/td>\n<td valign=\"top\" width=\"444\">7.28 lbs. (3.30 kg)<\/td>\n<\/tr>\n<tr>\n<td><strong>Hardware<\/strong><\/td>\n<td>\u25cf\u00a0\u00a0256MB DRAM with ECC memory<\/p>\n<p>\u25cf\u00a0\u00a0IEEE 1588v2 FPGA<\/p>\n<p>\u25cf\u00a0\u00a064MB on-board flash memory<\/p>\n<p>\u25cf\u00a0\u00a01GB removable SD flash memory card (optional)<\/td>\n<\/tr>\n<tr>\n<td><strong>Alarm<\/strong><\/td>\n<td>\u25cf\u00a0\u00a0Alarm-one alarm output relay using an M12 A Coded 5 Pin connector (Max. rated: 24VDC @ 1A\/48VDC @ 0.5A)<\/td>\n<\/tr>\n<tr>\n<td><strong>Input\u00a0voltage supported<\/strong><\/td>\n<td>\u25cf\u00a0 9.6-60VDC<\/p>\n<p>\u25cf\u00a0\u00a0PWR-IE160W-67-DC=: 18-60VDC, 12A<\/td>\n<\/tr>\n<tr>\n<td><strong>Power\u00a0rating<\/strong><\/td>\n<td>\u25cf\u00a0\u00a00.027KVA<\/td>\n<\/tr>\n<tr>\n<td><strong>Power consumption<\/strong><\/td>\n<td>\u25cf\u00a0\u00a010-20W<\/td>\n<\/tr>\n<tr>\n<td><strong>Connectors\u00a0and cabling<\/strong><\/td>\n<td>Data\u00a0cable<\/p>\n<p>\u25cf\u00a0\u00a0Copper 100 Base-T M12 D coded 4-pole (pin) cable connector<\/p>\n<p>\u25cf\u00a0\u00a0Copper GE M12 X coded-8-pole (pin)-cable connector<\/p>\n<p>Alarm\u00a0cable<\/p>\n<p>\u25cf\u00a0\u00a0M12 A-Coded 5-Pin Cable<\/p>\n<p>Console\u00a0cable<\/p>\n<p>\u25cf\u00a0\u00a0M12\u00a0A\u00a0Coded\u00a05-Pin\u00a0connector<\/p>\n<p>Power\u00a0supply\u00a0cables<\/p>\n<p>\u25cf\u00a0\u00a0Power cable for power source, Mini-Change A-Size single-ended cord set, 4 poles, female to pigtail, 16 AWG PVC cable.<\/p>\n<p>\u25cf\u00a0\u00a0Power cable to IE2000 IP67 switch: Mini-Change A-size double-Ended Cordset, 4 poles male to female. 16 AWG, TPE cable.<\/p>\n<p>\u25cf\u00a0\u00a0Power cable for AC-DC power source, Mini-change A-size single-ended cord set, 3 pins, female insert on one end to pigtail, 16 AWG PVC cable.<\/p>\n<p>\u25cf\u00a0\u00a0Power cord from power source to power supply: 2 hole female power cord to open for input DC connector.<\/td>\n<\/tr>\n<tr>\n<td><strong>Operating temperature<\/strong><\/td>\n<td>\u25cf\u00a0\u00a0-40\u00b0C to +75\u00b0C<\/p>\n<p>\u25cf\u00a0\u00a0\u00a0-40\u00b0C to +70\u00b0C (vented enclosure operating)<\/p>\n<p>\u25cf\u00a0\u00a0\u00a0-40\u00b0C to +60\u00b0C (sealed enclosure operating)<\/p>\n<p>\u25cf\u00a0\u00a0\u00a0-34\u00b0C to +75\u00b0C (200 LFM or more fan- or blower-equipped enclosure operating)<\/p>\n<p>\u25cf\u00a0\u00a0\u00a0-40\u00b0C to +85\u00b0C (type tested to +85\u00b0C for 16 hours)<\/p>\n<p>\u25cf\u00a0\u00a0\u00a0Altitude: Up to 13,800 feet (4570 meters)<\/td>\n<\/tr>\n<tr>\n<td><strong>Storage Temperature<\/strong><\/td>\n<td>\u25cf\u00a0\u00a0-40\u00b0C to +85\u00b0C<\/p>\n<p>\u25cf\u00a0\u00a0IEC 60068-2-14<\/p>\n<p>\u25cf\u00a0\u00a0Altitude: Up to 13,800 feet or 4,200 meters<\/td>\n<\/tr>\n<tr>\n<td><strong>MTBF<\/strong><\/td>\n<td>\u25cf\u00a0\u00a0Mean time between failures: 374,052 hours (42.7 years)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>IE-2000-16T67-B &#8211; Industrial Ethernet 2000 Series<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>IP67 IE 16 10\/100<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>PDF Attachment:<\/p>\n<p><a href=\"https:\/\/gntme.com\/wp-content\/uploads\/2021\/04\/ie-2000-16t67-b-datasheet-converted.pdf\">ie-2000-16t67-b datasheet<\/a><\/p>","protected":false},"featured_media":54542,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[536],"product_tag":[],"class_list":["post-18896","product","type-product","status-publish","has-post-thumbnail","product_cat-cisco-switches-cisco-industrial-ethernet-2000-switches-cisco","first","instock","sale","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/18896","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=18896"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/54542"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=18896"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=18896"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=18896"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=18896"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}