{"id":18757,"date":"2025-09-29T12:24:26","date_gmt":"2025-09-29T12:24:26","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=18757"},"modified":"2025-09-29T12:24:26","modified_gmt":"2025-09-29T12:24:26","slug":"ws-c3650-48pq-s-datasheet-2","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/ws-c3650-48pq-s-datasheet-2\/","title":{"rendered":"WS-C3650-48PQ-S Datasheet"},"content":{"rendered":"<p>[vc_row][vc_column][vc_column_text]<\/p>\n<p style=\"text-align: justify;\">Searching for a Cisco <strong>WS-C3650-48PQ-S Datasheet<\/strong> Switch for productive systems administration at your working environment? Search no more! Our <a href=\"https:\/\/gntme.com\/\" target=\"_blank\" rel=\"noopener\">gntme.com<\/a> site gives you the best cisco items that fulfill every one of your necessities.<\/p>\n<p style=\"text-align: justify;\">switches are the establishment of most business organizations, and how critical they are for your work environment. Through <a href=\"https:\/\/gntme.com\/product-category\/cisco\/cisco-switches\/\" target=\"_blank\" rel=\"noopener\">Cisco Switches<\/a>, gadgets associated with your organization can speak with each other and furthermore with different organizations effectively, much the same as the Internet. Cisco conveys a far-reaching arrangement of exchanging answers for Enterprise Networks, server farms, and more modest organizations. These arrangements are improved for a wide scope of enterprises, including specialist co-ops, monetary administrations, and the public area.<\/p>\n<p style=\"text-align: justify;\">The Cisco Catalyst <strong>WS-C3650-48PQ-S Datasheet<\/strong> series is the venture class independent &amp; stackable access-layer switch that gives the establishment to a full combination of wired &amp; remote on a solitary stage. The Cisco Catalyst <strong>WS-C3650-48PQ-S Datasheet<\/strong> is based on the high-level Cisco StackWise-160 and exploits the Cisco Unified Access Data Plane (UADP) application-explicit coordinated circuit (ASIC). This switch can empower uniform wired-remote arrangement implementation, application permeability, adaptability, application streamlining, and predominant versatility. The Cisco Catalyst <strong>WS-C3650-48PQ-S Datasheet<\/strong> arrangement switch bolsters full IEEE 802.3at Power over Ethernet Plus (PoE+), and offers measured and field-replaceable excess fans and force supplies. It can help you increment remote profitability and diminish your TCO.<\/p>\n<p style=\"text-align: justify;\">We are having <strong>Cisco WS-C3650-48PQ-S Datasheet Switches for sale<\/strong> and you can get these switches at an affordable rate. Take advantage of this sale and book your product now! Also, have a look at other Cisco Products, Cisco switches like <a href=\"https:\/\/gntme.com\/product\/ws-svc-asa-sm1-k9-2\/\" target=\"_blank\" rel=\"noopener\"><span data-sheets-value=\"\" data-sheets-userformat=\",&quot;4&quot;:,&quot;6&quot;:,,]},&quot;7&quot;:,,]},&quot;8&quot;:,,]},&quot;9&quot;:1,&quot;10&quot;:2,&quot;11&quot;:0,&quot;12&quot;:0,&quot;14&quot;:[null,2,0],&quot;15&quot;:&quot;Calibri, sans-serif&quot;,&quot;16&quot;:11}\">WS-SVC-ASA-SM1-K9<\/span><\/a>, C9200-48T-E, etc. For any kind of queries regarding the product and it&#8217;s purchase, you can contact <a href=\"mailto:sales@gntme.com\">sales@gntme.com<\/a><\/p>\n<table border=\"1\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td colspan=\"2\">\n<h3 align=\"center\"><strong>WS-C3650-48PQ-S Datasheet Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Enclosure type<\/p>\n<\/td>\n<td>\n<p align=\"left\">Rack-mountable &#8211; 1U<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Ports<\/p>\n<\/td>\n<td>\n<p align=\"left\">48 x 10\/100\/1000 (POE+)\u00a0 + 4 x 10G SFP+<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Network management Interface<\/p>\n<\/td>\n<td>\n<p align=\"left\">\u00b7 Ethernet management port: RJ-45 connectors, 4-pair Cat-5 UTP cabling<br \/>\n\u00b7 Management console port: RJ-45-to-DB9 cable for PC connections<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Available PoE Power<\/p>\n<\/td>\n<td>\n<p align=\"left\">390W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Switching Capacity<\/p>\n<\/td>\n<td>\n<p align=\"left\">176Gbps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Maximum stacking number<\/p>\n<\/td>\n<td>\n<p align=\"left\">9<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Stack Bandwidth<\/p>\n<\/td>\n<td>\n<p align=\"left\">160Gbps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Forwarding Performance<\/p>\n<\/td>\n<td>\n<p align=\"left\">130.95Mpps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">FNF entries<\/p>\n<\/td>\n<td>\n<p align=\"left\">Disabled (IP base license required)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Maximum VLANs IDs<\/p>\n<\/td>\n<td>\n<p align=\"left\">255<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">MAC Address Table Size<\/p>\n<\/td>\n<td>\n<p align=\"left\">32K<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">CPU<\/p>\n<\/td>\n<td>\n<p align=\"left\">Multicore CPU<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">RAM<\/p>\n<\/td>\n<td>\n<p align=\"left\">4 G<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Flash Memory<\/p>\n<\/td>\n<td>\n<p align=\"left\">2 G<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p align=\"center\"><strong>Wireless<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Number of AP per switch\/stack<\/p>\n<\/td>\n<td>\n<p align=\"left\">50<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Number of wireless clients per switch\/stack<\/p>\n<\/td>\n<td>\n<p align=\"left\">1000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Total number of WLANs per switch<\/p>\n<\/td>\n<td>\n<p align=\"left\">64<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Wireless bandwidth per switch<\/p>\n<\/td>\n<td>\n<p align=\"left\">up to 40Gbps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Supported Aironet AP series<\/p>\n<\/td>\n<td>\n<p align=\"left\">3700, 3600, 3500, 2600, 1600, 1260, 1140, 1040<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p align=\"center\"><strong>Expansion \/ Connectivity<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Console ports<\/p>\n<\/td>\n<td>\n<p align=\"left\">USB (Type-B), Ethernet (RJ-45)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Expansion Slot(s)<\/p>\n<\/td>\n<td>\n<p align=\"left\">\u00a0power redundant slot<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Accessory &amp; Rack Moubt Kits<\/p>\n<\/td>\n<td>\n<p align=\"left\">\u00b7 ACC-KIT-T1: Accessory kit<br \/>\n\u00b7 RACK-KIT-T1: Rack mount kit<br \/>\n\u00b7 4PT-KIT-T1:Extension rails and brackets for four-point mounting<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Stacking module &amp; cable<\/p>\n<\/td>\n<td>\n<p align=\"left\">\u00b7 C3650-STACK-KIT: Stack Module<br \/>\n\u00b7 STACK-T2-50CM: StackWise-160 stacking cable with a 0.5 m length<br \/>\n\u00b7 STACK-T2-1M: StackWise-160 stacking cable with a 1.0 m length<br \/>\n\u00b7 STACK-T2-3M: StackWise-160 stacking cable with a 3.0 m length<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Power supply<\/p>\n<\/td>\n<td>\n<p align=\"left\">PWR-C2-1025WAC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Power Device<\/p>\n<\/td>\n<td>\n<p align=\"left\">Power supply &#8211; redundant &#8211; plug-in module<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Power Redundancy<\/p>\n<\/td>\n<td>\n<p align=\"left\">optional<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Voltage range (Auto)<\/p>\n<\/td>\n<td>\n<p align=\"left\">100V-240V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Power Consumption of standalone (in Watts)<\/p>\n<\/td>\n<td>\n<p align=\"left\">107.4 (max)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p align=\"center\"><strong>Miscellaneous<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Width<\/p>\n<\/td>\n<td>\n<p align=\"left\">17.5 Inches (44.5 cm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Depth<\/p>\n<\/td>\n<td>\n<p align=\"left\">17.625 Inches (44.8 cm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Height<\/p>\n<\/td>\n<td>\n<p align=\"left\">1.73 Inches (4.4 cm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Shipping Weight<\/p>\n<\/td>\n<td>\n<p align=\"left\">17.49 Kg<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Rack Mounting Kit<\/p>\n<\/td>\n<td>\n<p align=\"left\">optional<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">\u00a0MTBF in hours<\/p>\n<\/td>\n<td>\n<p align=\"left\">383,760<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Compliant Standards<\/p>\n<\/td>\n<td>\n<p align=\"left\">\u00b7 IEEE 802.1D Spanning Tree Protoco<br \/>\n\u00b7 IEEE 802.1p CoS Prioritization<br \/>\n\u00b7 IEEE 802.1Q VLAN<br \/>\n\u00b7 IEEE 802.1s<br \/>\n\u00b7 IEEE 802.1w<br \/>\n\u00b7 IEEE 802.1X<br \/>\n\u00b7 IEEE 802.1X-Rev<br \/>\n\u00b7 IEEE 802.11<br \/>\n\u00b7 IEEE 802.1ab (LLDP)<br \/>\n\u00b7 IEEE 802.3ad<br \/>\n\u00b7 IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports<br \/>\n\u00b7 IEEE 802.3 10BASE-T<br \/>\n\u00b7 IEEE 802.3u 100BASE-TX<br \/>\n\u00b7 IEEE 802.3ab 1000BASE-T<br \/>\n\u00b7 IEEE 802.3z 1000BASE-X<br \/>\n\u00b7 RMON I and II standards<br \/>\n\u00b7 SNMP v1, v2c, and v3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p align=\"center\"><strong>System software \/ license<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">System software<\/p>\n<\/td>\n<td>\n<p align=\"left\">IOS IP Base (Upgradable)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">EnergyWise license<\/p>\n<\/td>\n<td>\n<p align=\"left\">ENERGY-MGMT, ENERGY-MGT-100-K9<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Software license<\/p>\n<\/td>\n<td>\n<p align=\"left\">\u00b7 C3650-48-S-E: IP Base to IP Services RTU paper license<\/p>\n<p align=\"left\">\u00b7 L-C3650-48-S-E: IP Base to IP Services RTU electronic license<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Access Point Licenses<\/p>\n<\/td>\n<td>\n<p align=\"left\">\u00b7 L-LIC-CT3650-UPG: Primary upgrade license SKU for Cisco 3650 wireless controller (e-delivery)<br \/>\n\u00b7 L-LIC-CTIOS-1A: 1 access point adder license for Cisco IOS Software based wireless controller (e-delivery)<br \/>\n\u00b7 L-LIC-CTIOS-1A: 1 access point adder license for Cisco IOS Software based wireless controller (e-delivery)<br \/>\n\u00b7 LIC-CTIOS-1A: 1 access point adder license for the Cisco IOS Software based wireless controller (paper license)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Features<\/p>\n<\/td>\n<td>\n<p align=\"left\">\u00b7 EEM\u00a0\u00b7 RPS Support\u00a0\u00a0\u00b7 IP service-level agreements (SLAs)\u00a0\u00a0\u00b7 Advanced IP unicast routing protocols<\/p>\n<p align=\"left\">\u00b7 Jumbo Frames\u00a0\u00b7 VLANS\u00a0\u00b7 Voice Vlan\u00a0\u00b7 VTPv2\u00a0\u00b7 CDPv2\u00a0\u00b7 LLDP\u00a0\u00b7 802.3ad LACP and PAgP\u00a0\u00b7 PVST\/PVST+<\/p>\n<p align=\"left\">\u00b7 802.1W\/802.1S\u00a0\u00b7 Port Fast\/Uplink Fast\u00a0\u00a0\u00b7 Dynamic Trunking Protocol (DTP)\u00a0\u00b7 port CoS Trust and Override<\/p>\n<p align=\"left\">\u00b7 Trusted Boundary\u00a0\u00b7 ACL Classification\u00a0\u00b7 ingress Policing\u00a0\u00b7 Auto QoS\u00a0\u00b7 Per VLAN policies\u00a0\u00b7 802.1p queues<\/p>\n<p align=\"left\">\u00b7 Scheduling\u00a0\u00b7 Priority Queuing\u00a0\u00b7 Configure CoS Priority Queues\u00a0\u00b7 Configure CoS Priority Queues<\/p>\n<p align=\"left\">\u00b7 Configure Queue Weights\u00a0\u00b7 Configure Buffers and Thresholds\u00a0\u00b7 Class &amp; Policy Maps\u00a0\u00b7 Modify CoS and DSCP Mapping<\/p>\n<p align=\"left\">\u00b7 Weighted Tail Drop\u00a0\u00b7 IGMPv1,v2,v3 and MLDv1, v2\u00a0\u00b7 DHCP server\u00a0\u00b7 DSCP transparency\u00a0\u00b7 HSRP, VRRP, BLGP<\/p>\n<p align=\"left\">\u00b7 RIPv1, v2 EIGRP, PIM\u00a0 OSPF, OSPFv3, EIGRPv6, BGPv4, IS-ISv4\u00a0\u00a0\u00b7 VRF-lite\u00a0\u00a0\u00b7 PIM-SM\/DM, PIM sparse-dense<\/p>\n<p align=\"left\">mode, SSM\u00a0\u00b7 Flexible Netflow<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Advanced Network security<\/p>\n<\/td>\n<td>\n<p align=\"left\">\u00b7 Port security\u00a0\u00b7 DHCP snooping\u00a0\u00b7 Dynamic ARP inspection (DAI)\u00a0\u00b7 IP source guard<\/p>\n<p align=\"left\">\u00b7 The Unicast Reverse Path Forwarding (uRPF)<br \/>\n\u00b7 Bidirectional data support on a SPAN\u00a0\u00b7 User authentication<br \/>\n\u00b7 Private VLAN\u00a0\u00a0\u00b7 Router and VLAN ACLs\u00a0\u00a0\u00b7 complete identity and security<br \/>\n\u00b7 Multidomain authentication\u00a0\u00b7 MAC address notification<br \/>\n\u00b7 IGMP filtering\u00a0\u00b7 Cisco security VLAN ACL<br \/>\n\u00b7 Secure Shell (SSH) Protocol, Kerberos, and Simple Network Management Protocol Version 3 (SNMPv3)<br \/>\n\u00b7 Port-based ACLs\u00a0\u00b7 TrustSec SXP\u00a0\u00b7 IEEE 802.1ae<br \/>\n\u00b7 TACACS+ and RADIUS authentication\u00a0\u00b7 Cisco standard and extended IP security router ACLs<br \/>\n\u00b7 Bridge protocol data unit (BPDU) Guard<br \/>\n\u00b7 Spanning Tree Root Guard (STRG)\u00a0\u00b7 Wireless end-to-end security<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Management<\/p>\n<\/td>\n<td>\n<p align=\"left\">\u00b7 BRIDGE-MIB\u00a0\u00b7 CISCO-AUTH-FRAMEWORK-MIB<br \/>\n\u00b7 CISCO-BGP4-MIB, BGP4-MIB\u00a0\u00b7 CISCO-BRIDGE-EXT-MIB<br \/>\n\u00b7 CISCO-BULK-FILE-MIB\u00a0\u00b7 CISCO-CABLE-DIAG-MIB<br \/>\n\u00b7 CISCO-CALLHOME-MIB\u00a0\u00b7 CISCO-CEF-MIB<br \/>\n\u00b7 CISCO-CIRCUIT-INTERFACE-MIB<br \/>\n\u00b7 CISCO-ENTITY-VENDORTYPE-OID-MIB<br \/>\n\u00b7 CISCO-CONTEXT-MAPPING-MIB<br \/>\n\u00b7 CISCO-DEVICE-LOCATION-MIB\u00a0\u00b7 CISCO-DHCP-SNOOPING-MIB<br \/>\n\u00b7 CISCO-EIGRP-MIB<br \/>\n\u00b7 CISCO-EMBEDDED-EVENT-MGR-MIB<br \/>\n\u00b7 CISCO-ENTITY-FRU-CONTROL-MIB\u00a0\u00b7 CISCO-ENTITY-SENSOR-MIB<br \/>\n\u00b7 ENTITY-MIB\u00a0\u00b7 CISCO-ERR-DISABLE-MIB<br \/>\n\u00b7 CISCO-CONFIG-COPY-MIB\u00a0\u00b7 CISCO-FLOW-MONITOR-MIB<br \/>\n\u00b7 CISCO-FTP-CLIENT-MIB\u00a0\u00b7 CISCO-HSRP-EXT-MIB<br \/>\n\u00b7 CISCO-HSRP-MIB\u00a0\u00b7 CISCO-IETF-ISIS-MIB<br \/>\n\u00b7 CISCO-IF-EXTENSION-MIB\u00a0\u00b7 CISCO-IGMP-FILTER-MIB<br \/>\n\u00b7 CISCO-CONFIG-MAN-MIB\u00a0\u00b7 CISCO-IP-CBR-METRICS-MIB<br \/>\n\u00b7 CISCO-IPMROUTE-MIB\u00a0\u00b7 CISCO-IP-STAT-MIB<br \/>\n\u00b7 CISCO-IP-URPF-MIB\u00a0\u00b7 CISCO-L2L3-INTERFACE-CONFIG-MIB<br \/>\n\u00b7 CISCO-LAG-MIB\u00a0\u00b7 CISCO-LICENSE-MGMT-MIB<br \/>\n\u00b7 CISCO-MAC-AUTH-BYPASS-MIB\u00a0\u00b7 CISCO-MAC-NOTIFICATION-MIB<br \/>\n\u00b7 CISCO-MDI-METRICS-MIB\u00a0\u00b7 CISCO-FLASH-MIB\u00a0\u00b7 CISCO-OSPF-MIB<br \/>\n\u00b7 CISCO-OSPF-TRAP-MIB\u00a0\u00b7 CISCO-PAE-MIB\u00a0\u00b7 CISCO-PAGP-MIB<br \/>\n\u00b7 CISCO-PIM-MIB\u00a0\u00b7 CISCO-PING-MIB\u00a0\u00b7 CISCO-PORT-QOS-MIB<br \/>\n\u00b7 CISCO-PORT-SECURITY-MIB\u00b7 CISCO-PORT-STORM-CONTROL-MIB<br \/>\n\u00b7 CISCO-POWER-ETHERNET-EXT-MIB\u00a0\u00b7 CISCO-PRIVATE-VLAN-MIB<br \/>\n\u00b7 CISCO-PROCESS-MIB\u00a0\u00b7 CISCO-PRODUCTS-MIB\u00b7 CISCO-RF-MIB<br \/>\n\u00b7 CISCO-RTP-METRICS-MIB\u00a0\u00b7 CISCO-RTTMON-MIB<br \/>\n\u00b7 CISCO-SMART-INSTALL-MIB<br \/>\n\u00b7 CISCO-SNMP-TARGET-EXT-MIB\u00a0\u00b7 CISCO-STACKMAKER-MIB<br \/>\n\u00b7 CISCO-MEMORY-POOL-MIB\u00a0\u00b7 CISCO-STP-EXTENSIONS-MIB<br \/>\n\u00b7 CISCO-SYSLOG-MIB\u00a0\u00b7 CISCO-TCP-MIB\u00a0\u00b7 CISCO-UDLDP-MIB<br \/>\n\u00b7 CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB\u00a0\u00b7 CISCO-VLAN-MEMBERSHIP-MIB<\/p>\n<p align=\"left\">\u00b7 CISCO-VTP-MIB\u00a0\u00b7 EtherLike-MIB<\/p>\n<p align=\"left\">\u00b7 HC-RMON-MIB\u00a0\u00b7 IEEE8021-PAE-MIB\u00a0\u00b7 IEEE8023-LAG-MIB<br \/>\n\u00b7 IF-MIB\u00a0\u00b7 IGMP-MIB\u00a0\u00b7 IGMP-STD-MIB\u00a0\u00b7 IP-FORWARD-MIB<br \/>\n\u00b7 IP-MIB\u00a0\u00b7 IPMROUTE-STD-MIB\u00a0\u00b7 LLDP-EXT-MED-MIB<br \/>\n\u00b7 LLDP-MIB\u00a0\u00b7 NOTIFICATION-LOG-MIB<br \/>\n\u00b7 OLD-CISCO-MEMORY-MIB\u00a0\u00b7 CISCO-CDP-MIB<br \/>\n\u00b7 POWER-ETHERNET-MIB\u00a0\u00b7 RMON2-MIB<br \/>\n\u00b7 RMON-MIB\u00a0\u00b7 SNMP-COMMUNITY-MIB\u00a0\u00b7 SNMP-FRAMEWORK-MIB<br \/>\n\u00b7 SNMP-MPD-MIB\u00a0\u00b7 SNMP-NOTIFICATION-MIB\u00a0\u00b7 SNMP-PROXY-MIB<br \/>\n\u00b7 SNMP-TARGET-MIB\u00a0\u00b7 SNMP-USM-MIB\u00a0\u00b7 SNMPv2-MIB<br \/>\n\u00b7 SNMP-VIEW-BASED-ACM-MIB\u00a0\u00b7 TCP-MIB\u00a0\u00b7 UDP-MIB<br \/>\n\u00b7 CISCO-IMAGE-MIB\u00a0\u00b7 CISCO-STACKWISE-MIB<br \/>\n\u00b7 AIRESPMACE-WIRELESS-MIB\u00a0\u00b7 CISCO-LWAPP-IDS-MIB<br \/>\n\u00b7 CISCO-LWAPP-AP-MIB\u00a0\u00b7 CISCO-LWAPP-CCX-RM-MIB<br \/>\n\u00b7 CISCO-LWAPP-CLIENT-ROAMING-MIB<br \/>\n\u00b7 CISCO-LWAPP-DOT11-CCX-CLIENT-DIAG-MIB<br \/>\n\u00b7 CISCO-LWAPP-DOT11-CCX-CLIENT-MIB<br \/>\n\u00b7 CISCO-LWAPP-DOT11-CLIENT-CCX-REPORTS-MIB<br \/>\n\u00b7 CISCO-LWAPP-DOT11-CLIENT-MIB\u00a0\u00b7 CISCO-LWAPP-DOT11-MIB<br \/>\n\u00b7 CISCO-LWAPP-DOWNLOAD-MIB\u00a0\u00b7 CISCO-LWAPP-LINKTEST-MIB<br \/>\n\u00b7 CISCO-LWAPP-MFP-MIB\u00a0\u00b7 CISCO-LWAPP-MOBILITY-EXT-MIB<br \/>\n\u00b7 CISCO-LWAPP-QOS-MIB\u00a0\u00b7 CISCO-LWAPP-REAP-MIB<br \/>\n\u00b7 CISCO-LWAPP-ROGUE-MIB\u00a0\u00b7 CISCO-LWAPP-RRM-MIB<br \/>\n\u00b7 CISCO-LWAPP-SI-MIB\u00a0\u00b7 CISCO-LWAPP-TSM-MIB<br \/>\n\u00b7 CISCO-LWAPP-WLAN-MIB\u00a0\u00b7 CISCO-LWAPP-WLAN-SECURITY-MIB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Technical Support and Services<\/p>\n<\/td>\n<td>\n<p align=\"left\">\u00b7 Cisco SMARTnet Service\u00a0\u00b7 Cisco Smart Foundation Service\u00a0\u00b7 Cisco SP Base Service<\/p>\n<p align=\"left\">\u00b7 Cisco Focused Technical Support Services<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p align=\"center\"><strong>Environmental Ranges<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p align=\"center\"><strong>With AC power supply<br \/>\nOperating environment and altitude<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Operating temperature up to 5000 ft (1500 m)<\/p>\n<\/td>\n<td>\n<p align=\"left\">23\u00baF to 113\u00baF (-5\u00baC to +45\u00baC)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Operating temperature up to 10,000 ft (3000 m)<\/p>\n<\/td>\n<td>\n<p align=\"left\">23\u00baF to 104\u00baF (-5\u00baC to +40\u00baC)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Short-term exception at sealevel with single fan failure<\/p>\n<\/td>\n<td>\n<p align=\"left\">23\u00baF to 113\u00baF (-5\u00baC to +45\u00baC)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Short-term exception up to 5000 feet (1500 m)<\/p>\n<\/td>\n<td>\n<p align=\"left\">23\u00baF to 122\u00baF (-5\u00baC to 50\u00baC)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Short-term exception up to 10,000 feet (3000 m)<\/p>\n<\/td>\n<td>\n<p align=\"left\">23\u00baF to 113\u00baF (-5\u00baC to 45\u00baC)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p align=\"center\"><strong>With DC power supply<br \/>\nOperating environment and altitude (NEBS)<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Operating temperature up to 6000 ft (1800 m)<\/p>\n<\/td>\n<td>\n<p align=\"left\">23\u00baF to 113\u00baF (-5\u00baC to +45\u00baC)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Operating temperature up to 10,000 ft (3000 m)<\/p>\n<\/td>\n<td>\n<p align=\"left\">23\u00baF to 104\u00baF (-5\u00baC to +40\u00baC)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Operating temperature up to 13,000 ft (4000m)<\/p>\n<\/td>\n<td>\n<p align=\"left\">23\u00baF to 95\u00baF (-5\u00baC to 35\u00baC)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Short-term exception up to 6,000 feet (1800 m)<\/p>\n<\/td>\n<td>\n<p align=\"left\">23\u00baF to 131\u00baF (-5\u00baC to +55\u00baC)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Short-term exception up to 10,000 feet (3000 m)<\/p>\n<\/td>\n<td>\n<p align=\"left\">23\u00baF to 122\u00baF (-5\u00baC to +50\u00baC)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Short-term exception up to 13,000 feet (4000 m)<\/p>\n<\/td>\n<td>\n<p align=\"left\">23\u00baF to 113\u00baF (-5\u00baC to +45\u00baC)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Short-term exception at sealevel with single fan failure<\/p>\n<\/td>\n<td>\n<p align=\"left\">23\u00baF to 113\u00baF (-5\u00baC to +45\u00ba)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Storage environment<\/p>\n<\/td>\n<td>\n<p align=\"left\">\u00a0-40\u00baF to 160\u00baF (-40\u00baC to 70\u00baC)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Operating altitude<\/p>\n<\/td>\n<td>\n<p align=\"left\">Up to 16,400 Feet (Up to 5000m)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Storage altitude<\/p>\n<\/td>\n<td>\n<p align=\"left\">Up to 16,400 Feet (Up to 5000m)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Operating relative humidity<\/p>\n<\/td>\n<td>\n<p align=\"left\">5% to 96% noncondensing<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Storage relative humidity<\/p>\n<\/td>\n<td>\n<p align=\"left\">5% to 96% noncondensing<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Short-term exception at sealevel with single fan failure<\/p>\n<\/td>\n<td>\n<p align=\"left\">23\u00baF to 113\u00baF<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"left\">Storage environment<\/p>\n<\/td>\n<td>\n<p align=\"left\">\u00a0-40\u00baF to 160\u00baF<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>","protected":false},"excerpt":{"rendered":"<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>WS-C3650-48PQ-S Datasheet &#8211;\u00a0 Catalyst 3650 Switch<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>Cisco Catalyst 3650 48 Port PoE 4x10G Uplink IP Base<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>PDF ATTACHMENT : <a href=\"https:\/\/gntme.com\/wp-content\/uploads\/2020\/05\/ws-c3650-48pq-s-datasheet.pdf\">ws-c3650-48pq-s-datasheet<\/a><\/p>","protected":false},"featured_media":54423,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[486],"product_tag":[],"class_list":{"0":"post-18757","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-switches-cisco-switch-catalyst-3650-cisco","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/18757","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=18757"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/54423"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=18757"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=18757"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=18757"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=18757"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}