{"id":18398,"date":"2025-09-29T12:19:00","date_gmt":"2025-09-29T12:19:00","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=18398"},"modified":"2025-09-29T12:19:00","modified_gmt":"2025-09-29T12:19:00","slug":"n3k-c3524p-xl-2","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/n3k-c3524p-xl-2\/","title":{"rendered":"N3K-C3524P-XL"},"content":{"rendered":"<h2><span data-sheets-value=\"\"><a href=\"https:\/\/itnetworks.ae\/n3k-c3524p-xl.html\" target=\"_blank\" rel=\"noopener\">n3k-c3524p-xl<\/a> datasheet<\/span><\/h2>\n<p style=\"text-align: justify;\">Searching for a Cisco N3K-C3524P-XL Switch for productive systems administration at your working environment? Search no more! Our <a href=\"https:\/\/gntme.com\/\" target=\"_blank\" rel=\"noopener\">gntme.com<\/a>\u00a0site gives you the best cisco items that fulfill every one of your necessities.<\/p>\n<p style=\"text-align: justify;\">N3K-C3524P-XL Switches are the establishment of most business organizations, and how critical they are for your work environment. Through <a href=\"https:\/\/gntme.com\/product-category\/cisco\/cisco-switches\/\" target=\"_blank\" rel=\"noopener\">Cisco Switches,<\/a> gadgets associated with your organization can speak with each other and furthermore with different organizations effectively, much the same as the Internet. Cisco conveys a far-reaching arrangement of exchanging answers for Enterprise Networks, server farms, and more modest organizations. These arrangements are improved for a wide scope of enterprises, including specialist co-ops, monetary administrations, and the public area.<\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">The Cisco Nexus N3K-C3524P-XL switch, the second member of the Cisco Nexus 3500 platform, is a compact 1RU form-factor 10 Gigabit Ethernet switch providing line-rate Layer 2 and 3 switchings with ultra-low latency. A license is required to enable the remaining 24 ports. The switch runs the Cisco NX-OS software operating system, providing customers with a comprehensive feature set, including Algo Boost technology and functions that are widely deployed globally. The Cisco Nexus 3524 contains no PHY chips, allowing low latency and low power consumption. This switch supports both forward and reversed airflow schemes and both AC and DC power inputs. Buy a similar product like <\/span><span style=\"font-size: 1.5rem;\"><span style=\"font-size: 14px;\"><a href=\"https:\/\/gntme.com\/product\/c1-n3k-c3132q-xl\/\" target=\"_blank\" rel=\"noopener\">C1-N3K-C3132Q-XL<\/a><\/span>.<\/span><\/p>\n<p><b>Main Features:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">XL<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Switch<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">L3<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">managed<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">24 x 1 Gigabit \/ 10 Gigabit SFP+<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">back to front airflow<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">rack-mountable<\/span><\/li>\n<\/ul>\n<table style=\"width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td style=\"width: 99.8201%;\" colspan=\"3\" valign=\"top\" width=\"553\">\n<h2 align=\"center\"><strong>N3K-C3524P-XL Specification<\/strong><\/h2>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Physical<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"bottom\" width=\"327\"><span style=\"font-size: 16px;\">\u00b7\u00a024 fixed SFP+ ports (1 or 10 Gbps); expandable to 48 ports<\/span><\/p>\n<p><span style=\"font-size: 16px;\">\u00b7\u00a0Dual redundant hot-swappable power supplies<\/span><\/p>\n<p><span style=\"font-size: 16px;\">\u00b7\u00a0Four individual redundant hot-swappable fans<\/span><\/p>\n<p><span style=\"font-size: 16px;\">\u00b7\u00a0One 1-PPS timing port, with the RF1.0\/2.3 QuickConnect connector type<\/span><\/p>\n<p><span style=\"font-size: 16px;\">\u00b7\u00a0One 10\/100\/1000-Mbps management port<\/span><\/p>\n<p><span style=\"font-size: 16px;\">\u00b7\u00a0One RS-232 serial console port<\/span><\/p>\n<p><span style=\"font-size: 16px;\">\u00b7\u00a0Two USB ports<\/span><\/p>\n<p><span style=\"font-size: 16px;\">\u00b7\u00a0Locator LED<\/span><\/p>\n<p><span style=\"font-size: 16px;\">\u00b7\u00a0Locator LED button<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Performance<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"bottom\" width=\"327\"><span style=\"font-size: 16px;\">\u00b7\u00a0480-Gbps switching capacity<\/span><\/p>\n<p><span style=\"font-size: 16px;\">\u00b7\u00a0Forwarding rate of 360 mpps<\/span><\/p>\n<p><span style=\"font-size: 16px;\">\u00b7\u00a0Line-rate traffic throughput (both Layer 2 and 3) on all ports<\/span><\/p>\n<p><span style=\"font-size: 16px;\">\u00b7\u00a0Configurable MTUs of up to 9216 bytes (jumbo frames)<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Typical operating power<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"bottom\" width=\"327\"><span style=\"font-size: 16px;\">\u00b7\u00a0102W<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Maximum power<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"bottom\" width=\"327\"><span style=\"font-size: 16px;\">\u00b7\u00a0193W<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Typical heat dissipation<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"bottom\" width=\"327\"><span style=\"font-size: 16px;\">\u00b7\u00a0348 BTUs per hr<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Maximum heat dissipation<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"bottom\" width=\"327\"><span style=\"font-size: 16px;\">\u00b7\u00a0658 BTUs per hr<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 99.8201%;\" colspan=\"3\" valign=\"top\"><span style=\"font-size: 16px;\"><strong>Hardware specifications common to all switches<\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Mode<\/strong><\/span><\/td>\n<td style=\"width: 35.4317%;\" valign=\"top\" width=\"167\"><span style=\"font-size: 16px;\"><strong>Normal mode<\/strong><\/span><\/td>\n<td style=\"width: 25.1799%;\" valign=\"top\"><span style=\"font-size: 16px;\"><strong>Warp mode<\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Number of MAC addresses<\/strong><\/span><\/td>\n<td style=\"width: 35.4317%;\" valign=\"top\" width=\"167\"><span style=\"font-size: 16px;\">64,000<\/span><\/td>\n<td style=\"width: 25.1799%;\" valign=\"top\"><span style=\"font-size: 16px;\">8000<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Number of IPv4 unicast routes<\/strong><\/span><\/td>\n<td style=\"width: 35.4317%;\" valign=\"top\" width=\"167\"><span style=\"font-size: 16px;\">24,000<\/span><\/td>\n<td style=\"width: 25.1799%;\" valign=\"top\"><span style=\"font-size: 16px;\">4000<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Number of IPv4 hosts<\/strong><\/span><\/td>\n<td style=\"width: 35.4317%;\" valign=\"top\" width=\"167\"><span style=\"font-size: 16px;\">64,000<\/span><\/td>\n<td style=\"width: 25.1799%;\" valign=\"top\"><span style=\"font-size: 16px;\">8000<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Number of IPv4 multicast routes<\/strong><\/span><\/td>\n<td style=\"width: 35.4317%;\" valign=\"top\" width=\"167\"><span style=\"font-size: 16px;\">8000<\/span><\/td>\n<td style=\"width: 25.1799%;\" valign=\"top\"><span style=\"font-size: 16px;\">8000<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Number of VLANS<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">4096<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Number of ACL entries<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">4096<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Number of spanning-tree instances<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">Rapid Spanning Tree Protocol (RSTP): 512<\/span><\/p>\n<p><span style=\"font-size: 16px;\">Multiple Spanning Tree (MST) Protocol: 64<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Number of EtherChannels<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">24<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Number of ports per EtherChannel<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">24<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Buffer size<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">6 MB shared among 16 ports; 18 MB total<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>System memory<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">16 GB<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Boot flash memory<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">16 GB<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Number of power supplies<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">2 (redundant)<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Power supply types<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">\u00b7\u00a0AC (forward and reversed airflow)<\/span><\/p>\n<p><span style=\"font-size: 16px;\">\u00b7\u00a0DC (forward\u00a0and reversed airflow)<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Input voltage<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">100 to 240 VAC<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Frequency<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">50 to 60 Hz<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Power supply efficiency<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">89 to 91% at 220V<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 99.8201%;\" colspan=\"3\" valign=\"top\"><span style=\"font-size: 16px;\"><strong>Forward and reversed airflow schemes<\/strong><\/span><\/p>\n<p><span style=\"font-size: 16px;\"><strong>\u00b7\u00a0Forward airflow: Port-side exhaust (air enters through fan tray and power supplies and exits through ports)<\/strong><\/span><\/p>\n<p><span style=\"font-size: 16px;\"><strong>\u00b7\u00a0Reversed airflow: Port-side intake (air enters through ports and exits through fan tray and power supplies)<\/strong><\/span><\/p>\n<p><span style=\"font-size: 16px;\"><strong>Four individual, hot-swappable fans (3+1 redundant)<\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Dimensions (height x width x depth)<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">1.72 x 17.3 x 18.38 in. (4.36 x 43.9 x 46.7 cm)<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Weight<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">17.4 lb (7.9 kg)<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Operating temperature<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">32 to 104\u00b0 F (0 to 40\u00b0C)<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Storage temperature<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">-40 to 158\u00b0 F (-40 to 70\u00b0C)<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Relative humidity (operating)<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">\u00b7\u00a010 to85% noncondensing<\/span><\/p>\n<p><span style=\"font-size: 16px;\">\u00b7\u00a0Up to 5 days at maximum (85%) humidity<\/span><\/p>\n<p><span style=\"font-size: 16px;\">\u00b7\u00a0Recommend ASHRAE\u00a0data center environment<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Relative humidity (nonoperating)<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">5 to 95% noncondensing<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 39.2086%;\" valign=\"top\" width=\"226\"><span style=\"font-size: 16px;\"><strong>Altitude<\/strong><\/span><\/td>\n<td style=\"width: 60.6115%;\" colspan=\"2\" valign=\"top\" width=\"327\"><span style=\"font-size: 16px;\">0 to 10,000 ft (0 to 3000m)<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td class=\"label\"><span style=\"font-size: 16px;\">Model:<\/span><\/td>\n<td>\n<h1><span style=\"font-size: 16px;\">N3K-C3524P-XL &#8211; Cisco Nexus 3000 Series<\/span><\/h1>\n<\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 16px;\">Detail:<\/span><\/td>\n<td>\n<h2><span style=\"font-size: 16px;\">Nexus 3524-XL Switch, 24 SFP+<\/span><\/h2>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"woocommerce-product-details__short-description\">\n<div class=\"woocommerce-product-details__short-description\">\n<p>PDF Attachment:<\/p>\n<p><a href=\"https:\/\/gntme.com\/wp-content\/uploads\/2021\/04\/n3k-c3524p-xl-datasheet-converted.pdf\">n3k-c3524p-xl datasheet<\/a><\/p>\n<p><a href=\"https:\/\/gntme.com\/wp-content\/uploads\/2021\/04\/guide-to-select-and-upgrade-cisco-data-center-switch-converted.pdf\">guide to select and upgrade cisco data center switch<\/a><\/p>\n<\/div>\n<\/div>","protected":false},"featured_media":54136,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[509],"product_tag":[],"class_list":{"0":"post-18398","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-switches-cisco-nexus-3000-series-cisco","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/18398","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=18398"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/54136"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=18398"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=18398"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=18398"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=18398"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}