{"id":18203,"date":"2025-09-29T12:16:54","date_gmt":"2025-09-29T12:16:54","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=18203"},"modified":"2025-09-29T12:16:54","modified_gmt":"2025-09-29T12:16:54","slug":"ws-c6513-e-2","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/ws-c6513-e-2\/","title":{"rendered":"WS-C6513-E"},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<h3 align=\"center\"><strong>WS-C6513-E Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Number of Slots<\/p>\n<\/td>\n<td valign=\"top\">\n<p>13<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Supervisor Compatibility<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Cisco Catalyst 6500 Series Supervisor Engine 32<\/p>\n<p>Cisco Catalyst 6500 Series Supervisor Engine 720-3B<\/p>\n<p>Cisco Catalyst 6500 Series Supervisor Engine 720-3BXL<\/p>\n<p>Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3C<\/p>\n<p>Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3CXL<\/p>\n<p>Cisco Catalyst 6500 Series Supervisor Engine 2T<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Power Supply Compatibility<\/p>\n<p>*&nbsp;Indicates EoS Power Supply<\/p>\n<\/td>\n<td valign=\"top\">\n<p>AC: 3000W, 4000W, 6000W, 8700W<\/p>\n<p>DC: 2500W, 4000W, 6000W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Module Compatibility<\/p>\n<\/td>\n<td valign=\"top\">\n<p>All modules based on the software release in the system<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<p>Software Compatibility&nbsp;(Minimum Software Version)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>With Supervisor Engine 32<\/p>\n<\/td>\n<td valign=\"top\">\n<p>\u25cf&nbsp;&nbsp;12.2(33)SXI1<\/p>\n<p>\u25cf&nbsp;&nbsp;12.2(33)SXH2<\/p>\n<p>\u25cf&nbsp;&nbsp;12.2(18)SXF14<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>With Supervisor Engine 720<\/p>\n<\/td>\n<td valign=\"top\">\n<p>\u25cf&nbsp;&nbsp;12.2(33)SXI1<\/p>\n<p>\u25cf&nbsp;&nbsp;12.2(33)SXH2<\/p>\n<p>\u25cf&nbsp;&nbsp;12.2(18)SXF14<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>With Supervisor Engine 720-10 GE<\/p>\n<\/td>\n<td valign=\"top\">\n<p>\u25cf&nbsp;&nbsp;12.2(33)SXI1<\/p>\n<p>\u25cf&nbsp;&nbsp;12.2(33)SXH2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>With Supervisor Engine 2T-10 GE<\/p>\n<\/td>\n<td valign=\"top\">\n<p>\u25cf&nbsp;&nbsp;15.0(1)SY<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Reliability and Availability<\/p>\n<p>Calculated Mean Time Between Failure (MTBF)<\/p>\n<\/td>\n<td valign=\"top\">\n<p>311,778<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>MIBS<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Check the corresponding supervisor engine data sheet<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Network Management<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Check the corresponding supervisor engine data sheet<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<p>Physical Dimensions<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Inches<\/p>\n<\/td>\n<td valign=\"top\">\n<p>32.7 x 17.3 x 18.1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Centimeters<\/p>\n<\/td>\n<td valign=\"top\">\n<p>83.0 x 43.9 x 46<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Rack Units (RU)<\/p>\n<\/td>\n<td valign=\"top\">\n<p>19<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<p>Weight<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Chassis Only (lbs)<\/p>\n<\/td>\n<td valign=\"top\">\n<p>102<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Fully Configured (lbs)<\/p>\n<\/td>\n<td valign=\"top\">\n<p>280<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Input Voltage<\/p>\n<\/td>\n<td valign=\"top\">\n<p>100 to 240 VAC<\/p>\n<p>-48 to -60 VDC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Safety<\/p>\n<\/td>\n<td valign=\"top\">\n<p>UL 60950 Second Edition<\/p>\n<p>CAN\/CSA-C22.2 No. 60950 Second Edition<\/p>\n<p>EN 60950 Second Edition<\/p>\n<p>IEC 60950 Second Edition<\/p>\n<p>AS\/NZS 60950<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>EMC<\/p>\n<\/td>\n<td valign=\"top\">\n<p>FCC Part 15 (CFR 47) Class A<\/p>\n<p>VCCI Class A<\/p>\n<p>EN55022 Class A<\/p>\n<p>CISPR 22 Class A<\/p>\n<p>CE marking<\/p>\n<p>AS\/NZS 3548 Class A<\/p>\n<p>ETS300 386<\/p>\n<p>EN55024<\/p>\n<p>EN61000-6-1<\/p>\n<p>EN50082-1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>NEBS\/ETSI<\/p>\n<\/td>\n<td valign=\"top\">\n<p>GR-1089-Core NEBS Level 3<\/p>\n<p>ETS 300 019 Storage Class 1.1<\/p>\n<p>ETS 300 019 Transportation Class 2.3<\/p>\n<p>ETS 300 019 Stationary Use Class 3.1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>ATIS Pb free and Energy Efficiency<\/p>\n<\/td>\n<td valign=\"top\">\n<p>ATIS-0600020.2010 Pb Free circuit packs<\/p>\n<p>ATIS-0600015-2009 General Energy Efficiency Requirements (TEER)<\/p>\n<p>ATIS-0600015.03-2009 Switch and Router Energy Efficiency<\/p>\n<p>ATIS-0600015.01-2009 Server Energy Efficiency<\/p>\n<p>VZ.TPR.9205 Verizon Energy Efficiency Requirements for Telecommunication Equipment (TEEER)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<p>Operating Environment<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Operating Temperature<\/p>\n<\/td>\n<td valign=\"top\">\n<p>32&deg;F to 104&deg;F (0 to 40&deg;C)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Storage Temperature<\/p>\n<\/td>\n<td valign=\"top\">\n<p>-4 to 149&deg;F (-20 to 65&deg;C)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Thermal Transition<\/p>\n<\/td>\n<td valign=\"top\">\n<p>0.5&deg;C per minute (hot to cold)<\/p>\n<p>0. 33&deg;C per minute (cold to hot)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Relative Humidity<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Ambient (noncondensing) operating: 5% to 90%<\/p>\n<p>Ambient (noncondensing) nonoperating and storage: 5% to 95%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Operating Altitude<\/p>\n<\/td>\n<td valign=\"top\">\n<p>Certified for operation: 0 to 6500 ft (0 to 2000 m)<\/p>\n<p>Designed and tested for operation: -200 to 10,000 ft (-60 to 3000 m)<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<table>< tbody > <\/p>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>WS-C6513-E Cisco 6500 Switch<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td itemprop=\"description\">Cisco Catalyst switch Enh C6513 Chassis, 13slot, 19RU, No Pow Supply, No Fan Tray<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":53939,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[515],"product_tag":[],"class_list":{"0":"post-18203","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-switches-cisco-switch-catalyst-6500-cisco-cisco-switches","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/18203","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=18203"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/53939"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=18203"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=18203"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=18203"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=18203"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}