{"id":17236,"date":"2025-09-29T12:04:53","date_gmt":"2025-09-29T12:04:53","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=17236"},"modified":"2025-09-29T12:04:53","modified_gmt":"2025-09-29T12:04:53","slug":"ws-c296024lc-s-2","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/ws-c296024lc-s-2\/","title":{"rendered":"WS-C2960+24LC-S"},"content":{"rendered":"<p>The Cisco Catalyst <a href=\"https:\/\/itnetworks.ae\/ws-c2960-24lc-s.html\" target=\"_blank\" rel=\"noopener\"><strong>WS-C2960-24LC-S<\/strong><\/a> switch with Power over Ethernet (PoE) function is a new member of the Cisco Catalyst 2960 series of stand-alone fixed configuration switches, suitable for entry-level enterprise, medium and small branch networks. The Cisco Catalyst <strong>WS-C2960-24LC-S<\/strong> with PoE can connect to power-over-Ethernet devices, including Cisco IP phones, wireless access points, and cameras.<\/p>\n<h3>WS-C2960-24LC-S \u00a0<strong>The<\/strong> <strong>Accessories<\/strong><\/h3>\n<ol>\n<li><a href=\"https:\/\/gntme.com\/cab-console-rj45\/\" target=\"_blank\" rel=\"noopener\">CAB-CONSOLE-RJ45<\/a><\/li>\n<li><a href=\"https:\/\/gntme.com\/glc-lh-sm\/\" target=\"_blank\" rel=\"noopener\">GLC-LH-SM<\/a><\/li>\n<li><a href=\"https:\/\/gntme.com\/glc-sx-mmd\/\" target=\"_blank\" rel=\"noopener\">GLC-SX-MMD<\/a><\/li>\n<\/ol>\n<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" align=\"center\">\n<h3><strong>WS-C2960+24LC-S Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\"><strong>Configurations<\/strong><\/td>\n<\/tr>\n<tr>\n<td>10\/100 Ethernet Interfaces<\/td>\n<td>24<\/td>\n<\/tr>\n<tr>\n<td>Uplink Interfaces<\/td>\n<td>2 (SFP or 1000BASE-T)<\/td>\n<\/tr>\n<tr>\n<td>Cisco IOS Software Feature Set<\/td>\n<td>LAN Lite<\/td>\n<\/tr>\n<tr>\n<td>Available PoE Power<\/td>\n<td>123W (8 ports up to 15.4W)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\"><strong>Hardware<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Flash memory<\/td>\n<td>64 MB<\/td>\n<\/tr>\n<tr>\n<td>DRAM<\/td>\n<td>128 MB<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\"><strong>Performance and Scalability WS-C2960+24LC-S<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Forwarding bandwidth<\/td>\n<td>16 Gbps<\/td>\n<\/tr>\n<tr>\n<td>Maximum active VLANs<\/td>\n<td>64<\/td>\n<\/tr>\n<tr>\n<td>VLAN IDs available<\/td>\n<td>4K<\/td>\n<\/tr>\n<tr>\n<td>Maximum transmission unit (MTU) &#8211; L3 packet<\/td>\n<td>9000 bytes<\/td>\n<\/tr>\n<tr>\n<td>Jumbo frame &#8211; Ethernet frame<\/td>\n<td>9018 bytes<\/td>\n<\/tr>\n<tr>\n<td>Forwarding Rate: 64-Byte L3 Packets, Millions of packets per second<\/td>\n<td>6.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\"><strong>Mechanical WS-C2960+24LC-S<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Dimensions (H x W x D)<\/td>\n<td>1.73 x 17.70 x 13.07\u00a0in (4.4 x 45.0 x 33.2 cm)<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>10 lb (4.5 Kg)<\/td>\n<\/tr>\n<tr>\n<td>Package Weight<\/td>\n<td>20.26 lb (9.19 Kg)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\"><strong>Environmental Ranges<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Operating temperature up to 5000 ft (1500 m)<\/td>\n<td>23\u00ba to 113\u00baF<\/p>\n<p>(-5\u00ba to 45\u00baC)<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature up to 10,000 ft (3000 m)<\/td>\n<td>23\u00ba to 104\u00baF<\/p>\n<p>(-5\u00ba to 40\u00baC)<\/td>\n<\/tr>\n<tr>\n<td>Short-term exception at sea level*<\/td>\n<td>23\u00ba to 131\u00baF<\/p>\n<p>(-5\u00ba to 55\u00baC)<\/td>\n<\/tr>\n<tr>\n<td>Short-term exception up to 5000 feet (1500 m)*<\/td>\n<td>23\u00ba to 122\u00baF<\/p>\n<p>(-5\u00ba to 50\u00baC)<\/td>\n<\/tr>\n<tr>\n<td>Short-term exception up to 10,000 feet (3000 m)*<\/td>\n<td>23\u00ba to 113\u00baF<\/p>\n<p>(-5\u00ba to 45\u00baC)<\/td>\n<\/tr>\n<tr>\n<td>Short-term exception up to 13,000 feet (4000 m)*<\/td>\n<td>23\u00ba to 104\u00baF<\/p>\n<p>(-5\u00ba to 40\u00baC)<\/td>\n<\/tr>\n<tr>\n<td>Storage temperature up to 15,000 feet (4573 m)<\/td>\n<td>23\u00ba to 158\u00baF<\/p>\n<p>(-25\u00ba to 70\u00baC)<\/td>\n<\/tr>\n<tr>\n<td>Operating altitude<\/td>\n<td>Up to 10,000 Feet<\/p>\n<p>(Up to 3,000 Meters)<\/td>\n<\/tr>\n<tr>\n<td>Storage altitude<\/td>\n<td>Up to 13,000 Feet<\/p>\n<p>(Up to 4,000 Meters)<\/td>\n<\/tr>\n<tr>\n<td>Operating relative humidity<\/td>\n<td>10% to 95% noncondensing<\/td>\n<\/tr>\n<tr>\n<td>Storage relative humidity<\/td>\n<td>10% to 95% noncondensing<\/td>\n<\/tr>\n<tr>\n<td>Sound Pressure, dBA<\/td>\n<td>Typical, LpAm: 43<\/p>\n<p>Maximum, LpAD: 46<\/td>\n<\/tr>\n<tr>\n<td>Sound Power, dbA<\/td>\n<td>Typical, LwA: 53<\/p>\n<p>Maximum, LwAD: 56<\/td>\n<\/tr>\n<tr>\n<td>MTBF in thousands of hours<\/td>\n<td>498<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\"><strong>Connectors and Interfaces<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Ethernet Interfaces<\/td>\n<td>\n<ul>\n<li>10BASE-T ports: RJ-45 connectors, 2-pair Category 3, 4, or 5 unshielded twisted-pair (UTP) cabling<\/li>\n<li>100BASE-TX ports: RJ-45 connectors, 2-pair Category 5 UTP cabling<\/li>\n<li>1000BASE-T ports: RJ-45 connectors, 4-pair Category 5 UTP cabling<\/li>\n<li>1000BASE-T SFP-based ports: RJ-45 connectors, 4-pair Category 5 UTP cabling<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>Indicator LEDs<\/td>\n<td>\n<ul>\n<li>Per-port status: Link integrity, disabled, activity, speed, and full duplex<\/li>\n<li>System status, Port Status, PoE, RPS, link duplex, and link speed<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>Console<\/td>\n<td>Cisco Catalyst console cables:<\/p>\n<ul>\n<li>CAB-CONSOLE-RJ45 Console cable 6 ft. with RJ-45<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>Power<\/td>\n<td>\n<ul>\n<li>The internal power supply is an auto-ranging unit and supports input voltages between 100 and 240V AC.<\/li>\n<li>Use the supplied AC power cord to connect the AC power connector to an AC power outlet.<\/li>\n<li>The Cisco RPS connector offers connection for an optional Cisco RPS 2300 that uses AC input and supplies DC output to the switch.<\/li>\n<li>Only the Cisco RPS 2300 (model PWR-RPS2300) should be attached to the redundant-power-system receptacle.<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\"><strong>Management and Standards Support<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Management<\/td>\n<td>\n<ul>\n<li>BRIDGE-MIB<\/li>\n<li>CISCO-CABLE-DIAG-MIB<\/li>\n<li>CISCO-CDP-MIB<\/li>\n<li>CISCO-CLUSTER-MIB<\/li>\n<li>CISCO-CONFIG-COPY-MIB<\/li>\n<li>CISCO-CONFIG-MAN-MIB<\/li>\n<li>CISCO-DHCP-SNOOPING-MIB<\/li>\n<li>CISCO-ENTITY-VENDORTYPE-OID-MIB<\/li>\n<li>CISCO-ENVMON-MIB<\/li>\n<li>CISCO-ERR-DISABLE-MIB<\/li>\n<li>CISCO-FLASH-MIB<\/li>\n<li>CISCO-FTP-CLIENT-MIB<\/li>\n<li>CISCO-IGMP-FILTER-MIB<\/li>\n<li>CISCO-IMAGE-MIB<\/li>\n<li>CISCO-IP-STAT-MIB<\/li>\n<li>CISCO-LAG-MIB<\/li>\n<li>CISCO-MAC-NOTIFICATION-MIB<\/li>\n<li>CISCO-MEMORY-POOL-MIB<\/li>\n<li>CISCO-PAGP-MIB<\/li>\n<li>CISCO-PING-MIB<\/li>\n<li>CISCO-POE-EXTENSIONS-MIB<\/li>\n<li>CISCO-PORT-QOS-MIB<\/li>\n<li>CISCO-PORT-SECURITY-MIB<\/li>\n<li>CISCO-PORT-STORM-CONTROL-MIB<\/li>\n<li>CISCO-PRODUCTS-MIB<\/li>\n<li>CISCO-PROCESS-MIB<\/li>\n<li>CISCO-RTTMON-MIB<\/li>\n<li>CISCO-SMI-MIB<\/li>\n<li>CISCO-STP-EXTENSIONS-MIB<\/li>\n<li>CISCO-SYSLOG-MIB<\/li>\n<li>CISCO-TC-MIB<\/li>\n<li>CICSO-TCP-MIB<\/li>\n<li>CISCO-UDLDP-MIB<\/li>\n<li>CISCO-VLAN-IFTABLE<\/li>\n<li>RELATIONSHIP-MIB<\/li>\n<li>CISCO-VLAN-MEMBERSHIP-MIB<\/li>\n<li>CISCO-VTP-MIB<\/li>\n<li>ENTITY-MIB<\/li>\n<li>ETHERLIKE-MIB<\/li>\n<li>IEEE8021-PAE-MIB<\/li>\n<li>IEEE8023-LAG-MIB<\/li>\n<li>IF-MIB<\/li>\n<li>INET-ADDRESS-MIB<\/li>\n<li>OLD-CISCO-CHASSIS-MIB<\/li>\n<li>OLD-CISCO-FLASH-MIB<\/li>\n<li>OLD-CISCO-INTERFACES-MIB<\/li>\n<li>OLD-CISCO-IP-MIB<\/li>\n<li>OLD-CISCO-SYS-MIB<\/li>\n<li>OLD-CISCO-TCP-MIB<\/li>\n<li>OLD-CISCO-TS-MIB<\/li>\n<li>RFC1213-MIB<\/li>\n<li>RMON-MIB<\/li>\n<li>RMON2-MIB<\/li>\n<li>SNMP-FRAMEWORK-MIB<\/li>\n<li>SNMP-MPD-MIB<\/li>\n<li>SNMP-NOTIFICATION-MIB<\/li>\n<li>SNMP-TARGET-MIB<\/li>\n<li>SNMPv2-MIB<\/li>\n<li>TCP-MIB<\/li>\n<li>UDP-MIB<\/li>\n<li>ePM MIB<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>Standards<\/td>\n<td>\n<ul>\n<li>IEEE 802.1D Spanning Tree Protocol<\/li>\n<li>IEEE 802.1p CoS Prioritization<\/li>\n<li>IEEE 802.1Q VLAN<\/li>\n<li>IEEE 802.1s<\/li>\n<li>IEEE 802.1w<\/li>\n<li>IEEE 802.1X<\/li>\n<li>IEEE 802.1ab (LLDP)<\/li>\n<li>IEEE 802.3ad<\/li>\n<li>IEEE 802.3af<\/li>\n<li>IEEE 802.3ah (100BASE-X single\/multimode fiber only)<\/li>\n<li>IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports<\/li>\n<li>IEEE 802.3 10BASE-T<\/li>\n<li>IEEE 802.3u 100BASE-TX<\/li>\n<li>IEEE 802.3ab 1000BASE-T<\/li>\n<li>IEEE 802.3z 1000BASE-X<\/li>\n<li>RMON I and II standards<\/li>\n<li>SNMP v1, v2c, and v3<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>RFC compliance<\/td>\n<td>\n<ul>\n<li>RFC 768 &#8211; UDP<\/li>\n<li>RFC 783 &#8211; TFTP<\/li>\n<li>RFC 791 &#8211; IP<\/li>\n<li>RFC 792 &#8211; ICMP<\/li>\n<li>RFC 793 &#8211; TCP<\/li>\n<li>RFC 826 &#8211; ARP<\/li>\n<li>RFC 854 &#8211; Telnet<\/li>\n<li>RFC 951 &#8211; Bootstrap Protocol (BOOTP)<\/li>\n<li>RFC 959 &#8211; FTP<\/li>\n<li>RFC 1112 &#8211; IP Multicast and IGMP<\/li>\n<li>RFC 1157 &#8211; SNMP v1<\/li>\n<li>RFC 1166 &#8211; IP Addresses<\/li>\n<li>RFC 1256 &#8211; Internet Control Message Protocol (ICMP) Router Discovery<\/li>\n<li>RFC 1305 &#8211; NTP<\/li>\n<li>RFC 1492 &#8211; TACACS+<\/li>\n<li>RFC 1493 &#8211; Bridge MIB<\/li>\n<li>RFC 1542 &#8211; BOOTP extensions<\/li>\n<li>RFC 1643 &#8211; Ethernet Interface MIB<\/li>\n<li>RFC 1757 &#8211; RMON<\/li>\n<li>RFC 1901 &#8211; SNMP v2C<\/li>\n<li>RFC 1902-1907 &#8211; SNMP v2<\/li>\n<li>RFC 1981 &#8211; Path MTU Discovery for IPv6<\/li>\n<li>FRC 2068 &#8211; HTTP<\/li>\n<li>RFC 2131 &#8211; DHCP<\/li>\n<li>RFC 2138 &#8211; RADIUS<\/li>\n<li>RFC 2233 &#8211; IF MIB v3<\/li>\n<li>RFC 2373 &#8211; IPv6 Aggregatable Addrs<\/li>\n<li>RFC 2460 &#8211; IPv6<\/li>\n<li>RFC 2461 &#8211; IPv6 Neighbor Discovery<\/li>\n<li>RFC 2462 &#8211; IPv6 Autoconfiguration<\/li>\n<li>RFC 2463 &#8211; ICMP IPv6<\/li>\n<li>RFC 2474 &#8211; Differentiated Services (DiffServ) Precedence<\/li>\n<li>RFC 2597 &#8211; Assured Forwarding<\/li>\n<li>RFC 2598 &#8211; Expedited Forwarding<\/li>\n<li>RFC 2571 &#8211; SNMP Management<\/li>\n<li>RFC 3046 &#8211; DHCP Relay Agent Information Option<\/li>\n<li>RFC 3376 &#8211; IGMP v3<\/li>\n<li>RFC 3580 &#8211; 802.1X RADIUS<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\"><strong>Voltage and Power Ratings WS-C2960+24LC-S<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Voltage (Autoranging)<\/td>\n<td>100 to 240 VAC<\/td>\n<\/tr>\n<tr>\n<td>Current (Amperes)<\/td>\n<td>1.4 &#8211; 0.8<\/td>\n<\/tr>\n<tr>\n<td>Frequency<\/td>\n<td>50 to 60Hz<\/td>\n<\/tr>\n<tr>\n<td>Power Rating (kVA)<\/td>\n<td>0.16<\/td>\n<\/tr>\n<tr>\n<td>DC Input Voltages (RPS Input)<\/td>\n<td>2A at 12V (3A at -52V)<\/td>\n<\/tr>\n<tr>\n<td>Power Consumption<\/td>\n<td>0% traffic: 25.9<\/p>\n<p>10% traffic: 25.7<\/p>\n<p>100% traffic: 26.1<\/p>\n<p>ATIS weighted average: 25.8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\"><strong>Safety and Compliance WS-C2960+24LC-S<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Regulatory Compliance<\/td>\n<td>Products should comply with CE Marking per directives 2004\/108\/EC and 2006\/95\/EC<\/td>\n<\/tr>\n<tr>\n<td>Safety<\/td>\n<td>UL 60950-1 Second Edition<\/p>\n<p>CAN\/CSA-C22.2 No. 60950-1 Second Edition<\/p>\n<p>EN 60950-1 Second Edition<\/p>\n<p>IEC 60950-1 Second Edition<\/p>\n<p>AS\/NZS 60950-1<\/td>\n<\/tr>\n<tr>\n<td>EMC &#8211; Emissions<\/td>\n<td>47CFR Part 15 (CFR 47) Class A<\/p>\n<p>AS\/NZS CISPR22 Class A<\/p>\n<p>CISPR22 Class A<\/p>\n<p>EN55022 Class A<\/p>\n<p>ICES003 Class A<\/p>\n<p>VCCI Class A<\/p>\n<p>EN61000-3-2<\/p>\n<p>EN61000-3-3<\/p>\n<p>KN22 Class A<\/p>\n<p>CNS13438 Class A<\/td>\n<\/tr>\n<tr>\n<td>EMC &#8211; Immunity<\/td>\n<td>EN55024<\/p>\n<p>CISPR24<\/p>\n<p>EN300386<\/p>\n<p>KN24<\/td>\n<\/tr>\n<tr>\n<td>Environmental <strong>WS-C2960+24LC-S<\/strong><\/td>\n<td>Reduction of Hazardous Substances (RoHS) including Directive 2011\/65\/EU<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>&lt; tbody &gt;<\/p>\n<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>WS-C2960+24LC-S Catalyst 2960 Plus Switch<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>Catalyst 2960 Plus 24 10\/100 (8 PoE) + 2 T\/SFP LAN Lite<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":53673,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[488],"product_tag":[],"class_list":{"0":"post-17236","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-switches-cisco-switch-catalyst-2960-cisco","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/17236","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=17236"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/53673"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=17236"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=17236"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=17236"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=17236"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}