{"id":15894,"date":"2025-09-29T11:54:57","date_gmt":"2025-09-29T11:54:57","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=15894"},"modified":"2025-09-29T11:54:57","modified_gmt":"2025-09-29T11:54:57","slug":"a9k-ism-100-2","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/a9k-ism-100-2\/","title":{"rendered":"A9K-ISM-100"},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<h3 align=\"center\"><strong>A9K-ISM-100 Specifications<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Type<\/strong><\/td>\n<td valign=\"top\">Cisco ASR 9000 Module AVSM ISM 40G<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Redundancy<\/strong><\/td>\n<td valign=\"top\">\u00b7 No single point of failure<\/p>\n<p>\u00b7 Fabric redundancy<\/p>\n<p>\u00b7 Power supply redundancy<\/p>\n<p>\u00b7 ISM redundancy (through CDSM)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Physical specifications<\/strong><\/td>\n<td valign=\"top\">Cisco ASR 9000 Series ISM (A9K-ISM-100) occupies one slot; can be inserted in any slot within the chassis:<\/p>\n<p>\u00b7 Height: 1.65 in. (4.19 cm.)<\/p>\n<p>\u00b7 Width: 15.86 in. (40.28 cm.)<\/p>\n<p>\u00b7 Depth: 23.91 in. (60.73 cm.)<\/p>\n<p>\u00b7 Weight: 18.35 lb<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Power input<\/strong><\/td>\n<td valign=\"top\">\u00b7 Worldwide ranging AC: 200\u2013240V; 50\u201360 Hz; 16A nominal<\/p>\n<p>\u00b7 Worldwide ranging DC: \u201348V to \u201360V; \u201354V; 50A nominal<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Environmental conditions<\/strong><\/td>\n<td valign=\"top\">\u00b7 Operating temperature: 32 to 104\u00b0F (0 to 40\u00b0C)<\/p>\n<p>\u00b7 Storage temperature: \u201340 to 167\u00b0F (\u201340 to 75\u00b0C)<\/p>\n<p>\u00b7 Relative humidity: 10 to 90%, noncondensing<\/p>\n<p>\u00b7 Regulatory compliance<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Power consumption<\/strong><\/td>\n<td valign=\"top\">\u00b7 Typical: 330W<\/p>\n<p>\u00b7 Maximum: 450W<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<p align=\"center\"><strong>Environmental Specifications<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Operating temperature (nominal)<\/strong><\/td>\n<td valign=\"top\">41 to 104\u00baF (5 to 40\u00baC)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Operating temperature<br \/>\n(short-term)<\/strong><\/td>\n<td valign=\"top\">23 to 131\u00baF (\u20135 to 55\u00baC)<\/p>\n<p>Short-term refers to a period of not more than 96 consecutive hours and a total of not more than 15 days in 1 year (total of 360 hours in any given year, but no more than 15 occurrences during that one-year period).<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Operating humidity (nominal) (relative humidity)<\/strong><\/td>\n<td valign=\"top\">10 to 85%<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Operating humidity<br \/>\n(short-term)<\/strong><\/td>\n<td valign=\"top\">5 to 90%<br \/>\nNote: Not to exceed 0.024 kg water or dry air<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Storage temperature<\/strong><\/td>\n<td valign=\"top\">\u201340 to 158\u00baF (\u201340 to 70\u00baC)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Storage (relative humidity)<\/strong><\/td>\n<td valign=\"top\">5 to 95%<br \/>\nNote: Not to exceed 0.024 kg water or dry air.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Operating altitude<\/strong><\/td>\n<td valign=\"top\">\u201360 to 4000m (up to 2000m conforms to IEC\/EN\/UL\/CSA 60950 requirements)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<p align=\"center\"><strong>Compliance<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>NEBS<\/strong><\/td>\n<td valign=\"top\">Cisco ASR 9000 Series Integrated Service Module is designed to meet:<\/p>\n<p>\u00b7 SR-3580: NEBS Criteria Levels (Level 3)<\/p>\n<p>\u00b7 GR-1089-CORE: NEBS EMC and Safety<\/p>\n<p>\u00b7 GR-63-CORE: NEBS Physical Protection<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>ETSI standards<\/strong><\/td>\n<td valign=\"top\">Cisco ASR 9000 series Integrated Service Module is designed to meet:<\/p>\n<p>\u00b7 EN300 386: Telecommunications Network Equipment (EMC)<\/p>\n<p>\u00b7 ETSI 300 019 Storage Class 1.1<\/p>\n<p>\u00b7 ETSI 300 019 Transportation Class 2.3<\/p>\n<p>\u00b7 ETSI 300 019 Stationary Use Class 3.1<\/p>\n<p>\u00b7 EN55022: Information Technology Equipment (Emissions)<\/p>\n<p>\u00b7 EN55024: Information Technology Equipment (Immunity)<\/p>\n<p>\u00b7 EN50082-1\/EN-61000-6-1: Generic Immunity Standard<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>EMC standards<\/strong><\/td>\n<td valign=\"top\">Cisco ASR 9000 series Integrated Service Module is designed to meet:<\/p>\n<p>\u00b7 FCC Class A<\/p>\n<p>\u00b7 ICES 003 Class A<\/p>\n<p>\u00b7 AS\/NZS 3548 Class A<\/p>\n<p>\u00b7 CISPR 22 (EN55022) Class A<\/p>\n<p>\u00b7 VCCI Class A<\/p>\n<p>\u00b7 BSMI Class A<\/p>\n<p>\u00b7 IEC\/EN 61000-3-2: Power Line Harmonics<\/p>\n<p>\u00b7 IEC\/EN 61000-3-3: Voltage Fluctuations and Flicker<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Immunity<\/strong><\/td>\n<td valign=\"top\">Cisco ASR 9000 series Integrated Service Module is designed to meet:<\/p>\n<p>\u00b7 IEC\/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)<\/p>\n<p>\u00b7 IEC\/EN-61000-4-3: Radiated Immunity (10V\/m)<\/p>\n<p>\u00b7 IEC\/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)<\/p>\n<p>\u00b7 IEC\/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)<\/p>\n<p>\u00b7 IEC\/EN-61000-4-5: Signal Ports (1kV)<\/p>\n<p>\u00b7 IEC\/EN-61000-4-5: Surge DC Port (1kV)<\/p>\n<p>\u00b7 IEC\/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)<\/p>\n<p>\u00b7 IEC\/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A\/m)<\/p>\n<p>\u00b7 IEC\/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Safety<\/strong><\/td>\n<td valign=\"top\">Cisco ASR 9000 series Integrated Service Module is designed to meet:<\/p>\n<p>\u00b7 UL\/CSA\/IEC\/EN 60950-1<\/p>\n<p>\u00b7 IEC\/EN 60825 Laser Safety<\/p>\n<p>\u00b7 ACA TS001<\/p>\n<p>\u00b7 AS\/NZS 60950<\/p>\n<p>\u00b7 FDA: Code of Federal Regulations Laser Safety<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>&lt; tbody &gt;<\/p>\n<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>A9K-ISM-100 Cisco ASR 9000 Series Service Module<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>Cisco ASR 9000 Module A9K-ISM-100 ASR9000 AVSM ISM 40G<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":57232,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[546],"product_tag":[],"class_list":{"0":"post-15894","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-router-asr-9000-cisco-routers","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/15894","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=15894"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/57232"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=15894"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=15894"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=15894"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=15894"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}