{"id":15854,"date":"2025-09-29T11:54:46","date_gmt":"2025-09-29T11:54:46","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=15854"},"modified":"2025-09-29T11:54:46","modified_gmt":"2025-09-29T11:54:46","slug":"asr-9006-ac-3","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/asr-9006-ac-3\/","title":{"rendered":"ASR-9006-AC"},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"100%\">\n<h3 align=\"center\"><strong>ASR-9006-AC Specifications<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Description<\/td>\n<td valign=\"top\" width=\"79%\">Cisco ASR 9006 Chassis, ASR-9006-AC, ASR-9006 AC Chassis<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"100%\">\n<p align=\"center\"><strong>Cisco ASR 9006 Specs<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Physical specifications<\/td>\n<td valign=\"top\" width=\"79%\">Height: 17.50 in. (444.5 mm) (10 RU)<\/p>\n<p>Width: 17.38 in. (441.45 mm)<\/p>\n<p>Depth:<\/p>\n<p>\u00b7 With doors: 29.05 in. (737.9 mm)<\/p>\n<p>\u00b7 Without doors: 29.05 in. (737.9 mm)<\/p>\n<p>Weight:<\/p>\n<p>\u00b7 89.55 lb (40.7 kg) (chassis with PEM)<\/p>\n<p>150 lb (65.91 kg) (fully loaded, excluding line cards and power modules) \u2013 RSP, two v2 FAN trays, PEMs<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Slot orientation<\/td>\n<td valign=\"top\" width=\"79%\">Horizontal<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Cisco ASR 9000 Series RSP<\/td>\n<td valign=\"top\" width=\"79%\">Dual redundant RSPs with integrated fabric in 2 slots<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Cisco ASR 9000 Series line\u00a0cards<\/td>\n<td valign=\"top\" width=\"79%\">4 line-card slots<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\u201cCommons\u201d components<\/td>\n<td valign=\"top\" width=\"79%\">2 RSPs<\/p>\n<p>2 fan trays<\/p>\n<p>1 PEM (either DC or AC)<\/p>\n<p>1 fan filter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Reliability and availability<\/td>\n<td valign=\"top\" width=\"79%\">Fabric redundancy<\/p>\n<p>Fan redundancy<\/p>\n<p>Feed redundancy<\/p>\n<p>Power-supply redundancy<\/p>\n<p>RSP redundancy<\/p>\n<p>Software redundancy<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Rack mounting<\/td>\n<td valign=\"top\" width=\"79%\">19-in. default<\/p>\n<p>21- and 23-in. adapters available<\/p>\n<p>Note:\u00a0Minimum 17.75-in. opening between posts is needed for proper operation<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Cabinet mounting<\/td>\n<td valign=\"top\" width=\"79%\">Yes<\/p>\n<p>Note:\u00a0Doors not recommended in enclosed cabinets<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Wall mounting<\/td>\n<td valign=\"top\" width=\"79%\">No<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Airflow<\/td>\n<td valign=\"top\" width=\"79%\">Right-to-back, Front-to-back with baffle<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"100%\">\n<p align=\"center\"><strong>Performance<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Fabric<\/td>\n<td valign=\"top\" width=\"79%\">One per RSP:<\/p>\n<p>\u00b7 Active\/active nonblocking operation mode in dual-RSP redundant configuration<\/p>\n<p>\u00b7 Fully redundant in dual-RSP redundant configuration<\/p>\n<p>\u00b7 Built-in service-intelligence and traffic-prioritization capability<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Thermal<\/td>\n<td valign=\"top\" width=\"79%\">Two fan trays:<\/p>\n<p>\u00b7 6 high-efficiency fans per tray<\/p>\n<p>\u00b7 Variable-speed fans for optimal thermal performance<\/p>\n<p>\u00b7 No single point of failure<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"100%\">\n<p align=\"center\"><strong>Power<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Modularity<\/td>\n<td valign=\"top\" width=\"79%\">Pay-as-you-grow power for future scalability, available in AC and DC.<\/p>\n<p>Multiple power module types:<\/p>\n<p>\u00b7 3 kW AC power module<\/p>\n<p>\u00b7 2.1 kW DC power module<\/p>\n<p>Note:\u00a0Mixing of AC and DC modules is not supported<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Redundancy<\/td>\n<td valign=\"top\" width=\"79%\">\u00b7 AC: N+N redundancy<\/p>\n<p>\u00b7 DC: N+1 redundancy<\/p>\n<p>\u00b7 Power module redundancy<\/p>\n<p>\u00b7 A\/B Feed redundancy<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Power zones<\/td>\n<td valign=\"top\" width=\"79%\">No power zone restrictions<\/p>\n<p>Fully load-sharing power infrastructure<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Power input<\/td>\n<td valign=\"top\" width=\"79%\">Worldwide ranging AC (200-240V; 50-60 Hz; 16A\u00a0maximum)<\/p>\n<p>Worldwide ranging DC (-40 to -72V; 50A nominal, 60A\u00a0maximum)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Power-module airflow<\/td>\n<td valign=\"top\" width=\"79%\">Front-to-back<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p align=\"left\">Operating temperature (nominal)<\/p>\n<\/td>\n<td valign=\"top\" width=\"79%\">\n<p align=\"left\">41 to 104\u00baF (5 to 40\u00baC)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p align=\"left\">Operating temperature (short-term)<a href=\"https:\/\/www.cisco.com\/c\/en\/us\/products\/collateral\/routers\/asr-9000-series-aggregation-services-routers\/data_sheet_c78-501767.html#_ftn2\" target=\"_blank\" rel=\"noopener\"><strong><br \/>\n<\/strong><\/a><\/p>\n<\/td>\n<td valign=\"top\" width=\"79%\">\n<p align=\"left\">ASR 9006: 23 to 131\u00baF (-5 to 55\u00baC)<\/p>\n<p align=\"left\">ASR 9010: 23 to 122\u00baF (-5 to 50\u00baC)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p align=\"left\">Operating humidity (nominal) (relative humidity)<\/p>\n<\/td>\n<td valign=\"top\" width=\"79%\">\n<p align=\"left\">5 to 90%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p align=\"left\">Storage temperature<\/p>\n<\/td>\n<td valign=\"top\" width=\"79%\">\n<p align=\"left\">-40 to 158\u00baF (-40 to 70\u00baC)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p align=\"left\">Storage (relative humidity)<\/p>\n<\/td>\n<td valign=\"top\" width=\"79%\">\n<p align=\"left\">5 to 93%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p align=\"left\">Operating altitude<\/p>\n<\/td>\n<td valign=\"top\" width=\"79%\">\n<p align=\"left\">-60 to 4000m (up to 2000m conforms to IEC\/EN\/UL\/CSA 60950 requirements)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p align=\"left\">Network Equipment Building Standards (NEBS)<\/p>\n<\/td>\n<td valign=\"top\" width=\"79%\">\n<p align=\"left\">Cisco ASR 9006 is designed to meet:<\/p>\n<p align=\"left\">\u00b7 SR-3580: NEBS Criteria Levels (Level 3)<\/p>\n<p align=\"left\">\u00b7 GR-1089-CORE: NEBS EMC and Safety<\/p>\n<p align=\"left\">\u00b7 GR-63-CORE: NEBS Physical Protection<\/p>\n<p align=\"left\">\u00b7 VZ.TPR.9205: Verizon TEEER<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p align=\"left\">ETSI standards<\/p>\n<\/td>\n<td valign=\"top\" width=\"79%\">\n<p align=\"left\">Cisco ASR 9006 is designed to meet:<\/p>\n<p align=\"left\">\u00b7 EN300 386: Telecommunications Network Equipment (EMC)<\/p>\n<p align=\"left\">\u00b7 ETSI 300 019 Storage Class 1.1<\/p>\n<p align=\"left\">\u00b7 ETSI 300 019 Transportation Class 2.3<\/p>\n<p align=\"left\">\u00b7 ETSI 300 019 Stationary Use Class 3.1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p align=\"left\">EMC standards emission<\/p>\n<\/td>\n<td valign=\"top\" width=\"79%\">\n<p align=\"left\">Cisco ASR 9006 is designed to meet:<\/p>\n<p align=\"left\">\u00b7 FCC Class 47CFR15 A<\/p>\n<p align=\"left\">\u00b7 ICES 003 Class A<\/p>\n<p align=\"left\">\u00b7 AS\/NZS CISRP22 Class A<\/p>\n<p align=\"left\">\u00b7 CISPR 22 (EN55022) Class A<\/p>\n<p align=\"left\">\u00b7 VCCI Class A<\/p>\n<p align=\"left\">\u00b7 BSMI Class A<\/p>\n<p align=\"left\">\u00b7 IEC\/EN 61000-3-12: Power Line Harmonics<\/p>\n<p align=\"left\">\u00b7 IEC\/EN 61000-3-11: Voltage Fluctuations and Flicker<\/p>\n<p align=\"left\">\u00b7 EN55022: Information Technology Equipment (Emissions)<\/p>\n<p align=\"left\">\u00b7 EN 50121-4: Railway EMC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p align=\"left\">EMC standards immunity<\/p>\n<\/td>\n<td valign=\"top\" width=\"79%\">\n<p align=\"left\">Cisco ASR 9006 is designed to meet:<\/p>\n<p align=\"left\">\u00b7 IEC\/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)<\/p>\n<p align=\"left\">\u00b7 IEC\/EN-61000-4-3: Radiated Immunity (10V\/m)<\/p>\n<p align=\"left\">\u00b7 IEC\/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)<\/p>\n<p align=\"left\">\u00b7 IEC\/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)<\/p>\n<p align=\"left\">\u00b7 IEC\/EN-61000-4-5: Signal Surge Ports (1kV)<\/p>\n<p align=\"left\">\u00b7 IEC\/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)<\/p>\n<p align=\"left\">\u00b7 IEC\/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)<\/p>\n<p align=\"left\">\u00b7 IEC\/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A\/m)<\/p>\n<p align=\"left\">\u00b7 IEC\/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations<\/p>\n<p align=\"left\">\u00b7 EN55024: Information Technology Equipment (Immunity)<\/p>\n<p align=\"left\">\u00b7 EN50082-1\/EN-61000-6-1: Generic Immunity Standard<\/p>\n<p align=\"left\">\u00b7 EN 50121-4: Railway EMC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p align=\"left\">Safety<\/p>\n<\/td>\n<td valign=\"top\" width=\"79%\">\n<p align=\"left\">Cisco ASR 9006 is designed to meet:<\/p>\n<p align=\"left\">\u00b7 UL\/CSA\/IEC\/EN 60950-1<\/p>\n<p align=\"left\">\u00b7 IEC\/EN 60825 Laser Safety<\/p>\n<p align=\"left\">\u00b7 ACA TS001<\/p>\n<p align=\"left\">\u00b7 AS\/NZS 60950<\/p>\n<p align=\"left\">\u00b7 FDA Code of Federal Regulations Laser Safety<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>&lt; tbody &gt;<\/p>\n<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>ASR-9006-AC Cisco ASR 9006 Series Chassis<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>Cisco ASR 9006 ChassisASR-9006-ACASR-9006 AC Chassis<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":54252,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[546],"product_tag":[],"class_list":{"0":"post-15854","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-router-asr-9000-cisco-routers","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/15854","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=15854"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/54252"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=15854"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=15854"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=15854"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=15854"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}