{"id":15845,"date":"2025-09-29T11:54:40","date_gmt":"2025-09-29T11:54:40","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=15845"},"modified":"2025-09-29T11:54:40","modified_gmt":"2025-09-29T11:54:40","slug":"spa-2xt3-e3-2","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/spa-2xt3-e3-2\/","title":{"rendered":"SPA-2XT3\/E3"},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<h3 align=\"center\"><strong>SPA-2XT3\/E3 Specifications<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Product compatibility<\/strong><\/td>\n<td valign=\"top\">\u2022 Cisco 7304 Router<\/p>\n<p>\u2022 Cisco 7600 Series Routers<\/p>\n<p>\u2022 Cisco 12000 Series Routers<\/p>\n<p>\u2022 Cisco ASR 9000 Series Router<\/p>\n<p>\u2022 Cisco XR 12000 Series Routers<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Port density per SPA<\/strong><\/td>\n<td valign=\"top\">2- and 4-port options<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Physical Interface<\/strong><\/td>\n<td valign=\"top\">\u2022 1.0\/2.3 RF connector (75-ohm impedance)<\/p>\n<p>\u2022 1.0\/2.3 RF to BNC adapter cable option<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Protocols<\/strong><\/td>\n<td valign=\"top\">Serial encapsulations:<\/p>\n<p>\u2022\u00a0\u00a0HDLC<\/p>\n<p>\u2022\u00a0\u00a0PPP, RFC 1662<\/p>\n<p>\u2022\u00a0\u00a0Frame Relay, RFC 1490<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Features and functions<\/strong><\/td>\n<td valign=\"top\">\u2022 Up to 4 independent T3 or E3 ports configurable as either all T3 or all E3 only<\/p>\n<p>\u2022 Full-duplex connectivity at T3 rate (44.736 MHz) or E3 rate (34.368 MHz)<\/p>\n<p>\u2022 Subrate and scrambling support of Quick Eagle Networks (formerly Digital Link), Larscom, ADC Kentrox,<\/p>\n<p>Adtran, and Verilink DSUs<\/p>\n<p>\u2022 Internal or network clock selectable per channel<\/p>\n<p>\u2022 Line and payload loopback capabilities:<\/p>\n<p>\u2013 Local and remote loopback at the T3 level<\/p>\n<p>\u2013 Response to embedded loopback commands<\/p>\n<p>\u2013 Insertion of loopback commands into transmitted signal<\/p>\n<p>Bit-error-rate-testing (BERT) pattern generation and detection per channel<\/p>\n<p>\u2013 Selectable pseudorandom pattern up to 32 bits long, including all 0\u2019s, all 1\u2019s, 215, 220, 220 QuasiRandom<\/p>\n<p>Signal Sequence (QRSS), 223, alternating 0\u2019s and 1\u2019s<\/p>\n<p>\u2013 32-bit error-count and bit-count registers<\/p>\n<p>\u2013 Fully independent transmit and receive sections<\/p>\n<p>\u2013 Detection of test patterns with bit error rates up to 10-2<\/p>\n<p>\u2022 24-hour history maintained for error statistics and failure counts, at 15-minute intervals<\/p>\n<p>\u2022 16- and 32-bit cyclic redundancy check (CRC); 16-bit default<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>T3-specific features<\/strong><\/td>\n<td valign=\"top\">C-bit or M23 framing<\/p>\n<p>\u2022 Binary 3-zero substitution (B3ZS) line coding<\/p>\n<p>\u2022 T3 far-end alarm and control (FEAC) channel support<\/p>\n<p>\u2022 Compliant with T3 pulse mask per ANSI T1.102-1993<\/p>\n<p>\u2022 Maintenance data link (MDL)<\/p>\n<p>\u2022 Line build-out up to 450 feet (135 meters)<\/p>\n<p>\u2022 Alarm monitoring<\/p>\n<p>\u2013 Alarm indication signal (AIS)<\/p>\n<p>\u2013 Loss of signal (LOS)<\/p>\n<p>\u2013 Out of frame (OOF)<\/p>\n<p>\u2013 Far-end receive failure (FERF)<\/p>\n<p>\u2022 Performance data collection<\/p>\n<p>\u2013 Line coding violation (LCV)<\/p>\n<p>\u2013 Framing bit errors (F- or M-bit errors)<\/p>\n<p>\u2013 P-bit error counts<\/p>\n<p>\u2013 C-bit error counts<\/p>\n<p>\u2013 Far-end block error (FEBE) counts<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>E3-specific features<\/strong><\/td>\n<td valign=\"top\">G.751, or G.832 and unframed G.703 framing<\/p>\n<p>\u2022 High-density bipolar with three zeroes (HDB3) line coding<\/p>\n<p>\u2022 Compliant with E3 pulse mask<\/p>\n<p>\u2022 Software-configurable E3 national service bits<\/p>\n<p>\u2022 Alarm monitoring<\/p>\n<p>\u2013 Alarm indication signal (AIS)<\/p>\n<p>\u2013 Loss of signal (LOS)<\/p>\n<p>\u2013 Out of frame (OOF)<\/p>\n<p>\u2013 Far-end receive failure (FERF)<\/p>\n<p>\u2022 Performance data collection<\/p>\n<p>\u2013 Line coding violation (LCV)<\/p>\n<p>\u2013 Framing-pattern errors<\/p>\n<p>\u2013 FEBE counts<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Reliability and availability<\/strong><\/td>\n<td valign=\"top\">\u2022\u00a0\u00a0OIR<\/p>\n<p>\u2022\u00a0\u00a0Single SPA software reset<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>MIBs<\/strong><\/td>\n<td valign=\"top\">RFC 2496 MIB (T3 MIB) and T1.231 MIB<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Network management<\/strong><\/td>\n<td valign=\"top\">Simple Network Management Protocol (SNMP)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Physical specifications<\/strong><\/td>\n<td valign=\"top\">\u2022\u00a0\u00a0Weight: 0.75 lb (0.34 kg)<\/p>\n<p>\u2022\u00a0\u00a0Height: 0.8 in. (2.03 cm) (single height)<\/p>\n<p>\u2022\u00a0\u00a0Width: 6.75 in. (17.15 cm)<\/p>\n<p>\u2022\u00a0\u00a0Depth: 7.28 in. (18.49 cm)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Power<\/strong><\/td>\n<td valign=\"top\">\u2022\u00a0\u00a02-port: 7.7W maximum<\/p>\n<p>\u2022\u00a0\u00a04-port: 8.4W maximum<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Compliance and agency approvals<\/strong><\/td>\n<td valign=\"top\">CE Marking<\/p>\n<p>Safety<\/p>\n<p>\u2022 UL 60950<\/p>\n<p>\u2022 CSA 22.2 No.60950<\/p>\n<p>\u2022 IEC 60950<\/p>\n<p>\u2022 EN 60950<\/p>\n<p>\u2022 AS\/NZS 3260<\/p>\n<p>\u2022 TS001<\/p>\n<p>EMC<\/p>\n<p>\u2022 CFR47 Part 15<\/p>\n<p>\u2022 ICES 003<\/p>\n<p>\u2022 EN55022<\/p>\n<p>\u2022 CISPR 22<\/p>\n<p>\u2022 AS\/NZ 3548<\/p>\n<p>\u2022 VCCI<\/p>\n<p>\u2022 EN55024<\/p>\n<p>\u2022 EN50082-1<\/p>\n<p>\u2022 EN61000-6-1<\/p>\n<p>Telecom (T3)<\/p>\n<p>\u2022 ANSI T1 107<\/p>\n<p>\u2022 T1 404<\/p>\n<p>\u2022 AT&amp;T 54014<\/p>\n<p>Telecom (E3)<\/p>\n<p>\u2022 G.703<\/p>\n<p>\u2022 G.751<\/p>\n<p>\u2022 G.832<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Environmental specifications<\/strong><\/td>\n<td valign=\"top\">\u2022 Operating temperature: 41 to 104\u00b0F (5 to 40\u00b0C)<\/p>\n<p>\u2022 Storage temperature: \u201338 to 150\u00b0F (\u201340 to 70\u00b0C)<\/p>\n<p>\u2022 Operating humidity: 5 to 85% relative humidity<\/p>\n<p>\u2022 Storage humidity: 5 to 95% relative humidity<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>&lt; tbody &gt;<\/p>\n<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>SPA-2XT3\/E3 Cisco ASR 9000 Series Shared Port Adapter<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>Cisco ASR 9000 Adapter SPA-2XT3\/E3 2-port Clear Channel T3\/E3 Shared Port Adapter<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":57226,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[546],"product_tag":[],"class_list":{"0":"post-15845","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-router-asr-9000-cisco-routers","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/15845","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=15845"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/57226"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=15845"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=15845"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=15845"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=15845"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}