{"id":14316,"date":"2025-09-29T11:45:38","date_gmt":"2025-09-29T11:45:38","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=14316"},"modified":"2025-09-29T11:45:38","modified_gmt":"2025-09-29T11:45:38","slug":"spa-2xoc48pos-rpr-2","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/spa-2xoc48pos-rpr-2\/","title":{"rendered":"SPA-2XOC48POS\/RPR"},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"100%\">\n<h3 align=\"center\"><strong>SPA-2XOC48POS\/RPR Specifications<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Type<\/strong><\/td>\n<td valign=\"top\" width=\"70%\">Cisco Router Shared Port Adapter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Product Compatibility<\/strong><\/td>\n<td valign=\"top\" width=\"70%\">Cisco Catalyst 6500 Series Switches<\/p>\n<p>Cisco 7600 Series Routers<\/p>\n<p>Cisco 12000 Series Routers<\/p>\n<p>Cisco XR 12000 Series Routers<\/p>\n<p>Cisco ASR 1000 Series Router<\/p>\n<p>Cisco ASR 9000 Series Router(2 port only)<\/p>\n<p>Cisco CRS Carrier Routing System(2 and 4 port only)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Port Density per SPA<\/strong><\/td>\n<td valign=\"top\" width=\"70%\">1, 2, and 4 ports<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Physical Interface<\/strong><\/td>\n<td valign=\"top\" width=\"70%\">OC-48c\/STM-16c SFP optics module (see optical parameters below)<\/p>\n<p>Visual status indicators (LEDs)<\/p>\n<p>\u2022 SPA status LED<\/p>\n<p>\u2022 Per port LEDs<\/p>\n<p>\u2022 Carrier\/Alarm<\/p>\n<p>\u2022 Active\/Loopback<\/p>\n<p>\u2022 Protect (DPT\/RPR mode)<\/p>\n<p>\u2022 Pass Through (DPT\/RPR mode)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Protocols (see table below for RPR\/SRP support info)<\/strong><\/td>\n<td valign=\"top\" width=\"70%\">High-Level Data Link Control (HDLC), RFC 2615<\/p>\n<p>Point-to-Point Protocol (PPP), RFC 1662<\/p>\n<p>Frame Relay, RFC 2427<\/p>\n<p>IPv4\/IPv6<\/p>\n<p>IEEE 802.17 &#8211; Resilient Packet Ring (RPR)<\/p>\n<p>IETF 2892 &#8211; Spatial Reuse Protocol (SRP)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Features and Functions<\/strong><\/td>\n<td valign=\"top\" width=\"70%\">Synchronization<\/p>\n<p>\u2022 Local (internal) or loop timed (recovered from network)<\/p>\n<p>\u2022 Stratum 3 clock accuracy (\u00b1 4.6 ppm) over full operating temperature<\/p>\n<p>\u2022 Pointer activity monitoring<\/p>\n<p>Local (diagnostic) and line (network) loopback<\/p>\n<p>Section DCC (SDCC) &#8211; Platform-dependent feature<\/p>\n<p>Payload mapping<\/p>\n<p>\u2022 1 + X^43 self-synchronous scrambler<\/p>\n<p>SONET\/SDH compliance<\/p>\n<p>\u2022 Telecordia (Bellcore) GR-253-CORE (as applicable)<\/p>\n<p>\u2022 ANSI T1.105, T1.231<\/p>\n<p>\u2022 ITU-T G.707, G.957, G.825 (as applicable)<\/p>\n<p>Supported SONET\/SDH alarm and signal events<\/p>\n<p>\u2022 Signal Failure Bit Error Rate (SF-BER)<\/p>\n<p>\u2022 Signal Degrade Bit Error Rate (SD-BER)<\/p>\n<p>\u2022 Signal Label Payload Construction (C2)<\/p>\n<p>\u2022 Path Trace Byte (J1)<\/p>\n<p>\u2022 Section<\/p>\n<p>\u2022 Loss of Signal (LOS)<\/p>\n<p>\u2022 Loss of Frame (LOF)<\/p>\n<p>\u2022 Error Counts for B1<\/p>\n<p>\u2022 Threshold Crossing Alarms (TCA) for B1<\/p>\n<p>\u2022 Line<\/p>\n<p>\u2022 Line Alarm Indication Signal (LAIS)<\/p>\n<p>\u2022 Line Remote Defect Indication (LRDI)<\/p>\n<p>\u2022 Line Remote Error Indication (LREI)<\/p>\n<p>\u2022 Error Counts for B2<\/p>\n<p>\u2022 Threshold Crossing Alarms (TCA) for B2<\/p>\n<p>\u2022 Path<\/p>\n<p>\u2022 Path Alarm Indication Signal (PAIS)<\/p>\n<p>\u2022 Path Remote Defect Indication (PRDI)<\/p>\n<p>\u2022 Path Remote Error Indication (PREI)<\/p>\n<p>\u2022 Error Counts for B3<\/p>\n<p>\u2022 Threshold Crossing Alarms (TCA) for B3<\/p>\n<p>\u2022 Loss of Pointer (LOP)<\/p>\n<p>\u2022 Positive Stuffing Event (PSE)<\/p>\n<p>\u2022 Negative Stuffing Event (NSE)<\/p>\n<p>\u2022 Path Unequipped Indication Signal (PUNEQ)<\/p>\n<p>\u2022 Path Payload Mismatch Indication Signal (PPLM)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Network Management<\/strong><\/td>\n<td valign=\"top\" width=\"70%\">RFC 2558 MIB (SONET\/SDH)<\/p>\n<p>Simple Network Management Protocol (SNMP)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Reliability and Availability<\/strong><\/td>\n<td valign=\"top\" width=\"70%\">Online insertion and removal (OIR)<\/p>\n<p>Field-replaceable SFP optical modules<\/p>\n<p>1+1 SONET Automatic Protection Switching (APS) and SDH Linear Multiplexer Section Protection (MSP) protocols<\/p>\n<p>Single SPA software reset<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Physical Specifications<\/strong><\/td>\n<td valign=\"top\" width=\"70%\">Weight: 0.75 lbs (0.34 kg)<\/p>\n<p>Height: 0.8 inches (2.03 cm)<\/p>\n<p>Width: 6.75 inches (17.15 cm)<\/p>\n<p>Depth: 7.28 inches (18.49 cm)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Power<\/strong><\/td>\n<td valign=\"top\" width=\"70%\">18 Watts maximum (4-port)<\/p>\n<p>15.5 Watts maximum (1-, 2-, and 4-Port)<\/p>\n<p>12 Watts maximum (1-port)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Environmental Specifications<\/strong><\/td>\n<td valign=\"top\" width=\"70%\">Operating temperature: 41\u00b0\u00a0to 104\u00b0F (5\u00b0\u00a0to 40\u00b0C)<\/p>\n<p>Storage temperature: -38\u00b0\u00a0to 150\u00b0F (-40\u00b0\u00a0to 70\u00b0C)<\/p>\n<p>Operating humidity: 5 to 85% relative humidity<\/p>\n<p>Storage humidity: 5 to 95% relative humidity<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Compliance and Agency Approvals<\/strong><\/td>\n<td valign=\"top\" width=\"70%\">Safety<\/p>\n<p>UL 60950<\/p>\n<p>CSA 22.2-No.60950<\/p>\n<p>EN60950<\/p>\n<p>IEC 60950 CB Scheme<\/p>\n<p>ACA TS001<\/p>\n<p>AS\/NZS 3260<\/p>\n<p>EN60825IEC60825 laser safety (SR, IR-Class 1) (VSR-Class 1M)1<\/p>\n<p>21CFR1040 -FDA Code of Federal Regulations (USA) laser safety (SR, IR-Class 1) (VSR-Class 1M)1<\/p>\n<p>EMC<\/p>\n<p>FCC Part 15 (CFR 47)<\/p>\n<p>ICES 003<\/p>\n<p>EN55022<\/p>\n<p>CISPR 22<\/p>\n<p>AS\/NZ 3548<\/p>\n<p>VCCI<\/p>\n<p>EN55024<\/p>\n<p>EN50082-1<\/p>\n<p>EN61000-6-1<\/p>\n<p>EN61000-3-2<\/p>\n<p>EN61000-3-3<\/p>\n<p>Network Equipment Building System (NEBS)<\/p>\n<p>This product is designed to meet the following requirements (official qualification may be in progress):<\/p>\n<p>SR-3580 &#8211; NEBS: criteria levels (Level 3 compliant)<\/p>\n<p>GR-63-Core &#8211; NEBS: physical protection<\/p>\n<p>GR-1089-Core &#8211; NEBS: EMC and safety<\/p>\n<p>European Telecommunications Standard Institute (ETSI)<\/p>\n<p>EN300 386\/EN300 386-2 Class B<\/p>\n<p>ETS 300 019 Storage Class 1.1<\/p>\n<p>ETS 300 019 Transportation Class 2.3<\/p>\n<p>ETS 300 019 Stationary Use Class 3.1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>&lt; tbody &gt;<\/p>\n<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>SPA-2XOC48POS\/RPR Cisco ASR 9000 Series Shared Port Adapter<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>Cisco ASR 9000 Adapter SPA-2XOC48POS\/RPR 2-port OC48\/STM16 POS\/RPR Shared Port Adapters<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":57242,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[546],"product_tag":[],"class_list":{"0":"post-14316","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-router-asr-9000-cisco-routers","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/14316","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=14316"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/57242"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=14316"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=14316"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=14316"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=14316"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}