{"id":14142,"date":"2025-09-29T11:44:34","date_gmt":"2025-09-29T11:44:34","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=14142"},"modified":"2025-09-29T11:44:35","modified_gmt":"2025-09-29T11:44:35","slug":"asr1000-rp2","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/asr1000-rp2\/","title":{"rendered":"ASR1000-RP2"},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<h3 align=\"center\"><strong>ASR1000-RP2 Specifications<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Chassis support<\/td>\n<td valign=\"top\">Cisco ASR 1004, ASR 1006, ASR 1006-X, ASR 1009-X and ASR 1013 chassis<\/p>\n<p>(Note: The Cisco ASR 1002 and ASR 1002 Fixed chassis come with the Cisco ASR 1000 Series RP1 built into the chassis.)<\/p>\n<p>(Note: Cisco ASR 1001, ASR 1001-X, and ASR 1002-X (part numbers ASR1001, ASR1001-X, ASR1002-X) have an integrated Route Processor built in to the chassis that is not upgradable)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Software compatibility<\/td>\n<td valign=\"top\">Cisco IOS XE Software, which is based on Cisco IOS Software Release 12.2SR<\/p>\n<p>(Please consult your Cisco account representative for additional details.)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Software protocols<\/td>\n<td valign=\"top\">Refer to Cisco IOS Software 12.2SR protocol support<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Connectivity<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0Console port (RJ-45 connector)<\/p>\n<p>\u25cf\u00a0\u00a0Auxiliary port (RJ-45 connector)<\/p>\n<p>\u25cf\u00a0\u00a010\/100\/1000 Ethernet port (RJ-45 connector)<\/p>\n<p>\u25cf\u00a0\u00a0RJ-48 connector for BITS input clock and output source<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Memory options<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0Four 2-GB DDR2 mini-DIMMs<\/p>\n<p>\u25cf\u00a0\u00a0Four 4 GB DDR2 mini-DIMMs<\/p>\n<p>\u25cf\u00a0\u00a0Upgradable memory from 8-GB to 16-GB DRAM<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Storage options<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a080-GB HDD (hot-swappable)<\/p>\n<p>\u25cf\u00a0\u00a01-GB USB Compact Flash memory<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Performance<\/td>\n<td valign=\"top\">With 8-GB memory:<\/p>\n<p>\u25cf\u00a0\u00a0Up to 1,000,000 IPv4 routes or 1,000,000 IPv6 routes<\/p>\n<p>\u25cf\u00a0\u00a0BGP RR Scalability up to 8,000,000 IPv4 routes or 6,000,000 IPv6 routes<\/p>\n<p>With 16-GB memory:<\/p>\n<p>\u25cf\u00a0\u00a0Up to 4,000,000 IPv4 routes or 4,000,000 IPv6 routes<\/p>\n<p>\u25cf\u00a0\u00a0BGP RR Scalability up to 24,000,000 IPv4 routes or 17,000,000 IPv6 routes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Reliability and availability<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a01 + 1 redundancy in dual-route-processor configuration<\/p>\n<p>\u25cf\u00a0\u00a0Support for OIR<\/p>\n<p>\u25cf\u00a0\u00a0Support for NSF and SSO<\/p>\n<p>\u25cf\u00a0\u00a0Support for ISSU<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">MIBs<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0RFC 2737 compliant<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Network management<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0Telnet and SSH (CLI)<\/p>\n<p>\u25cf\u00a0\u00a0Console port (through the CLI)<\/p>\n<p>\u25cf\u00a0\u00a0SNMP<\/p>\n<p>\u25cf\u00a0\u00a0RFC 2665<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">LEDs<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0PWR &#8211; Power<\/p>\n<p>Green &#8211; All power rails are within specifications<\/p>\n<p>\u25cf\u00a0\u00a0STAT &#8211; Status<\/p>\n<p>Green &#8211; Cisco IOS Software has booted<\/p>\n<p>Yellow &#8211; BootROM has successfully loaded<\/p>\n<p>Red &#8211; System failure or during boot process<\/p>\n<p>\u25cf\u00a0\u00a0ACTV- Active<\/p>\n<p>Green &#8211; Active route processor<\/p>\n<p>\u25cf\u00a0\u00a0STBY &#8211; Standby<\/p>\n<p>Yellow &#8211; Standby route processor<\/p>\n<p>\u25cf\u00a0\u00a0CRIT &#8211; Critical Alarm<\/p>\n<p>Red &#8211; Critical alarm or during boot process<\/p>\n<p>\u25cf\u00a0\u00a0MAJ &#8211; Major Alarm<\/p>\n<p>Red &#8211; Major alarm<\/p>\n<p>\u25cf\u00a0\u00a0MIN &#8211; Minor Alarm<\/p>\n<p>Amber &#8211; Minor alarm<\/p>\n<p>\u25cf\u00a0\u00a0HD &#8211; Internal HDD<\/p>\n<p>FLASH Green &#8211; Activity indicator<\/p>\n<p>Off &#8211; No activity<\/p>\n<p>\u25cf\u00a0\u00a0USB &#8211; External Compact Flash<\/p>\n<p>FLASH green &#8211; Activity indicator<\/p>\n<p>\u25cf\u00a0\u00a0BF &#8211; Boot Flash (Internal)<\/p>\n<p>FLASH green &#8211; Activity indicator<\/p>\n<p>Off &#8211; No activity<\/p>\n<p>\u25cf\u00a0\u00a0CARRIER<\/p>\n<p>BITS I\/F Mode<\/p>\n<p>Off &#8211; Out of service or not configured<\/p>\n<p>Green &#8211; Normal or Bridging<\/p>\n<p>Amber &#8211; Fast<\/p>\n<p>\u25cf\u00a0\u00a0DTI Mode<br \/>\nOff &#8211; Warm-up, free-run, or holdover<br \/>\nGreen &#8211; In service or working properly<br \/>\nAmber &#8211; Fault or loop condition<\/p>\n<p>\u25cf\u00a0\u00a0LINK &#8211; Management Ethernet link status<br \/>\nSolid green &#8211; Link with no activity<br \/>\nFLASH green &#8211; Link with activity<br \/>\nOff &#8211; No link<\/p>\n<p>\u25cf\u00a0\u00a0DISK2 &#8211; Internal HDD<br \/>\nFLASH green &#8211; Activity indicator<br \/>\nOff &#8211; No activity<\/p>\n<p>\u25cf\u00a0\u00a0CARRIER &#8211; BITS interface<br \/>\nOff &#8211; Out of service<br \/>\nGreen &#8211; In frame and in service<br \/>\nAmber &#8211; Fault or loop condition<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Physical dimensions\u00a0(H\u00a0x W x D)<\/td>\n<td valign=\"top\">0.92 x 16.7 x 14.19 in. (0.02 x 0.428 x 0.36m)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Weight<\/td>\n<td valign=\"top\">5.0 lb (2.3 kg)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Approvals and compliance<\/td>\n<td valign=\"top\">Safety<\/p>\n<p>\u25cf\u00a0\u00a0UL60950-1 and CAN\/CSA-C22.2 No. 60950-1-03 Information technology equipment<\/p>\n<p>\u25cf\u00a0\u00a0AS\/NZS 60950-1<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN 60950-1 Information technology equipment<\/p>\n<p>\u25cf\u00a0\u00a073\/23\/EEC<\/p>\n<p>Electromagnetic Emissions Certification<\/p>\n<p>\u25cf\u00a0\u00a0CFR 47 Part 15: (FCC) Class A<\/p>\n<p>\u25cf\u00a0\u00a0ICES 003 Class A<\/p>\n<p>\u25cf\u00a0\u00a0AS\/NZ CISPR 22: Class A<\/p>\n<p>\u25cf\u00a0\u00a0CISPR 22 (EN55022) Class A<\/p>\n<p>\u25cf\u00a0\u00a0VCCI Class A<\/p>\n<p>\u25cf\u00a0\u00a0KN22<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN 61000-3-2 (or 3-12 as applicable): AC Power Line Harmonics<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN 61000-3-3 (or 3-11 as applicable): AC Voltage Fluctuations and Flicker<\/p>\n<p>Immunity<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN-61000-4-2: Electrostatic Discharge Immunity (8-kV Contact, 15-kV Air)<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN-61000-4-3: Radiated Immunity (10 V\/m)<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN-61000-4-4: Electrical Fast Transient Immunity (2-kV Power, 1-kV Signal)<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN-61000-4-5: Surge AC Port (4-kV CM, 2-kV DM)<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN-61000-4-5: Surge Signal Ports (1-kV indoor, 2-kV outdoor)<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN-61000-4-5: Surge DC Port 1-kV<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30 A\/m)<\/p>\n<p>\u25cf\u00a0\u00a0IEC\/EN-61000-4-11: Voltage Dips, Short Interruptions, and Voltage Variations<\/p>\n<p>Network Equipment Building Standards<\/p>\n<p>The module meets the following NEBS:<\/p>\n<p>\u25cf\u00a0\u00a0GR-1089-CORE<\/p>\n<p>\u25cf\u00a0\u00a0GR-63-CORE<\/p>\n<p>ETSI and EN Standards<\/p>\n<p>\u25cf\u00a0\u00a0EN300 386: Telecommunications Network Equipment (EMC), OTC<\/p>\n<p>\u25cf\u00a0\u00a0EN55022: Information Technology Equipment (Emissions)<\/p>\n<p>\u25cf\u00a0\u00a0EN55024: Information Technology Equipment (Immunity)<\/p>\n<p>\u25cf\u00a0\u00a0EN50082-1\/EN-61000-6-1: 1995-Generic Immunity Standard<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Environmental<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0Storage temperature: -38 to 150\u00b0F (-40 to 70\u00b0C)<\/p>\n<p>\u25cf\u00a0\u00a0Operating temperature, nominal: 41 to 104\u00b0F (5 to 40\u00b0C)<\/p>\n<p>\u25cf\u00a0\u00a0Operating temperature, short-term: 23 to 131\u00b0F (-5 to 55\u00b0C)<\/p>\n<p>\u25cf\u00a0\u00a0Storage relative humidity: 5 to 95% RH<\/p>\n<p>\u25cf\u00a0\u00a0Operating humidity, nominal: 5 to 85% RH<\/p>\n<p>\u25cf\u00a0\u00a0Operating humidity, short-term: 5 to 90% RH<\/p>\n<p>\u25cf\u00a0\u00a0Operating altitude: -60 to 4000m (up to 2000m conforms to IEC\/EN\/UL\/CSA 60950 requirements)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>&lt; tbody &gt;<\/p>\n<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>ASR1000-RP2 Cisco ASR 1000 Processor<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>Cisco ASR 1000 Processor ASR1000-RP2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":57197,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[521],"product_tag":[],"class_list":{"0":"post-14142","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-router-asr-1000-cisco-routers","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/14142","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=14142"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/57197"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=14142"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=14142"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=14142"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=14142"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}