{"id":12894,"date":"2025-09-29T11:34:56","date_gmt":"2025-09-29T11:34:56","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=12894"},"modified":"2025-09-29T11:34:56","modified_gmt":"2025-09-29T11:34:56","slug":"ws-x45-sup8l-e","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/ws-x45-sup8l-e\/","title":{"rendered":"WS-X45-SUP8L-E="},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"100%\">\n<h3 align=\"center\"><strong>WS-X45-SUP8L-E= Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"100%\">\n<p align=\"center\"><strong>Feature<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>STATUS LED<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>The status LED indicates the current health of the supervisor engine and the current software state.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>RESET switch (recessed)<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>The RESET switch is used to reset and restart the switch.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>UID LED and switch combination<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>A combination push button switch and LED indicator. The blue LED can be turned on either by pressing the UID switch on the front panel or through software.<\/p>\n<p>The main purpose of the beacon LED is to enable identification from a remote location during configuration or troubleshooting.<\/p>\n<p>The ability to turn on\/off the LED by pressing a switch allows you to walk to the other side of a fully populated rack and identify the switch. Pressing the blue beacon LED switch toggles the beacon LED on and off.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>USB ports<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>USB ports are supported.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>CONSOLE port (RJ-45 connector)<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>This is a 10\/100\/1000 port that uses an RJ-45 connector. The console port allows you to access the switch either locally (with a console terminal) or through a modem (remote). The port has an RJ-45 connector. The console port allows you to perform the following functions:<\/p>\n<p>Configure the switch from the CLI<\/p>\n<p>Monitor network statistics and errors<\/p>\n<p>Configure SNMP agent parameters<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>10\/100\/1000 MGT port (RJ-45 connector)<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>The Ethernet management port is a Layer 3 host port to which you can connect a PC. You can use the Ethernet management port instead of the switch console port for network management. When managing a switch, connect the PC to the Ethernet management port on a Catalyst 4500 E-series switch.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>LINK LED (Management port)<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>The 10\/100\/1000 MGT port has a link LED associated with it.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>SECURE DIGITAL slot<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>A standard Secure Data (SD) memory card interface is provided on the front panel.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>SD LED<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>The SD LED indicates the current status of the SD memory card slot.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>ACTIVE SUP LED<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>The active supervisor engine LED indicates whether the supervisor engine is active or in standby mode in redundant supervisor engine configurations.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>UTILIZATION LEDs<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>Eight LEDs indicate (as an approximate percentage) the current traffic load over the backplane.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>1G\/10G UPLINKS (SFP\/SFP+) ports .<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>The Supervisor Engine 8L-E has four 1-G or 10-G ports that use either small form-factor pluggable (SFP) transceivers or SFP+ transceivers.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>Uplink port LEDs<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>The uplink port LEDs display the status and activity of the uplink ports.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"100%\">\n<p align=\"center\"><strong>Supervisor Engine 8L-E Front Panel LEDs&mdash;Color and Meaning<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>STATUS<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>Indicates the status of the Supervisor Engine:<\/p>\n<p>Green&mdash;All diagniostic tests have passed.<\/p>\n<p>Orange&mdash;System boot or a diagnostic test is in progress.<\/p>\n<p>Red&mdash;A diagnostic test failed.<\/p>\n<p>Off&mdash;The supervisor engine is disabled or is not powered up.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>LINK<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>Indicates the status of the 10\/100\/1000 BASE-T Ethernet management port:<\/p>\n<p>Green&mdash;The link is operational.<\/p>\n<p>Off&mdash;No signal is detected, or there is a link configuration failure, or the link is disabled by user.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>SD<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>Indicates the status of the secure digital port:<\/p>\n<p>Green&mdash;SD card is inserted.<\/p>\n<p>Off&mdash;SD card has been removed, or the SD card is bad.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>ACTIVE SUP<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>Indicates whether the Supervisor Engine is active or in standby mode:<\/p>\n<p>Green&mdash;Supervisor engine is active (in redundant supervisor engine configurations)<\/p>\n<p>Off&mdash;Supervisor engine is in standby mode (in redundant supervisor engine configurations)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>UTILIZATION<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>When the switch is operational, the eight utilization LEDs indicate the current traffic load over the backplane as an approximate percentage value. Each LED-lit green indicates approximately 12.5 percent of load.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>Uplink port status<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>Indicates the status of the uplink port:<\/p>\n<p>Green&mdash;The link is operational.<\/p>\n<p>Orange&mdash;The link is disabled by user.<\/p>\n<p>Flashing orange&mdash;The power-on self-test indicates a faulty port.<\/p>\n<p>Off&mdash;No signal is detected or there is a link configuration failure.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"40%\">\n<p>Uplink port active<\/p>\n<\/td>\n<td valign=\"top\" width=\"59%\">\n<p>Two LEDs on the front panel show the uplink port activity:<\/p>\n<p>1-2 ACTIVE indicates that ports 1 and 2 are active<\/p>\n<p>3-4 ACTIVE indicates that ports 3 and 4 are active<\/p>\n<p>In standalone supervisor engine configurations, all four uplink ports are active; all of the ACTIVE LEDs are lit green.<\/p>\n<p>In redundant supervisor engine configurations, only the 1-2 ACTIVE LED is lit green.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<table>< tbody > <\/p>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>WS-X45-SUP8L-E= &#8211; Cisco Catalyst 4500-X Switch Module<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td itemprop=\"description\">Catalyst 4500 E-Series Supervisor 8L-E, Spare<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":56875,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[648],"product_tag":[],"class_list":{"0":"post-12894","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-4500-switch-modules-cisco-modules-cards","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/12894","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=12894"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/56875"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=12894"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=12894"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=12894"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=12894"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}