{"id":12439,"date":"2025-09-29T11:31:50","date_gmt":"2025-09-29T11:31:50","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=12439"},"modified":"2025-09-29T11:31:50","modified_gmt":"2025-09-29T11:31:50","slug":"c4kx-nm-8sfp-2","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/c4kx-nm-8sfp-2\/","title":{"rendered":"C4KX-NM-8SFP+"},"content":{"rendered":"<table border=\"1\">\n<thead>\n<tr>\n<td colspan=\"2\" valign=\"bottom\">\n<h3 align=\"center\"><strong>C4KX-NM-8SFP+ Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"bottom\">\n<p align=\"center\"><strong>System<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Management Port<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>10\/100\/1000 Base-T<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>USB Port<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Type A (storage and boot) up-to 4 GB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Dual Power Supply<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Field Replaceable Fans<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Yes (5 fans)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Fan Redundancy<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>No performance impact with single fan failure<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"bottom\">\n<p align=\"center\"><strong>Scalability<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>System Throughput<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Up to 800 Gbps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>IPv4 Routing in Hardware<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Up to 250 Mpps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>IPv6 Routing in Hardware<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Up to 125 Mpps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>L2 Bridging in Hardware<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Up to 250 Mpps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Media Access Control (MAC) Entries<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>55K<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Flexible Netflow Entries<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>128K<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Switched Port Analyzer (SPAN), Remote Switched Port Analyzer (RSPAN)<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>8 line rate bidirectional sessions (ingress and egress)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Total VLANs<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>4094<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Total Switched Virtual Interfaces (SVIs)<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>4094<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>IGMP groups<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>32K<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Dynamic Host Configuration Protocol (DHCP) Snooping Entries<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>12K (DHCP snooping bindings)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>ARP Entries<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>47K<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Spanning Tree Protocol Instances<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>10K<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Jumbo Frame Support for Bridged and Routed Packets<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Up to 9216 bytes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"bottom\">\n<p align=\"center\"><strong>High Availability and Resiliency<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>High Availability Solution<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Virtual Switching System (VSS)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Number of stackable switches in VSS<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Up to 2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>VSS Throughput<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Up to 1.6 Tbps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Virtual Switch Link<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>1GE or 10GE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Max number of Virtual Switch Links<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>In-Service Software Upgrade<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Across the switches<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Nonstop Forwarding with Stateful Switchover<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Across the switches<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"bottom\">\n<p align=\"center\"><strong>CPU and Memory<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Onboard Memory (SRAM DDR-II)<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>4 GB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Port Buffers<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>32-MB Shared Memory<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>CPU<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Dual Core 1.5 GHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>NVRAM<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>2 GB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Optional External Memory (SD&nbsp;Card)<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>2 GB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"bottom\">\n<p align=\"center\"><strong>QoS Features<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Port Queues<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>8 Queues\/Port<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>CPU Queues<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>64<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>QoS Entries<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>128K (64K ingress and 64K in egress) Shared with ACL<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Aggregate Rate-Limiting<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Ingress port or VLAN and egress VLAN or Layer 3 port<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Rate-Limiting Level Types<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Committed Information Rate (CIR), Peak Information Rate (PIR)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Aggregate Traffic Rate-Limiting Policers (1K=1024)<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>16K<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Flow-Based Rate-Limiting Method; Number of Rates<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Supported using flow-records in the classification criteria and policing action<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Qos Policy Enforcement<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Per Port or Per Vlan or Per Port, Per VLAN Granularity<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Class of Service (CoS)<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Differentiated Services Code Point (DSCP)<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"bottom\">\n<p align=\"center\"><strong>Security Features<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Port Security<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>IEEE 802.1x and 802.1x Extensions<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>VLAN, Router, and Port ACLs<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Security ACL Entries (1K=1024)<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>128K (64K ingress and 64K in egress) Shared with QoS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Unicast Reverse Path Forwarding (uRPF) Check in Hardware<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>CPU Rate Limiters (DoS Protection) Includes Control Plane Policing<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Private VLANs<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Micro Flow Policer<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Yes. Supported using flow records in the class-map<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>CPU HW Rate Limiters by Packet Per Second (pps) and Bit Rate Policers (bps)<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Supported in hardware control-plane policing (CoPP)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Control Plane Policing (CoPP) for Multicast<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>ACL Labels<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Port ACL<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Traffic Storm Control (formally known as Broadcast\/Multicast Suppression)<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"bottom\">\n<p align=\"center\"><strong>Virtualization Features<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>VRF-Lite Scalability<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>64<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Easy Virtual Network (EVN) Scalability<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>32<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"bottom\">\n<p align=\"center\"><strong>Environmental Conditions<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Operating Temperature<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>0&deg;C to 40&deg;C (RH to 90%)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Storage Temperature<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>-40&deg;C to 70&deg;C (RH 93%)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Operating Altitude<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>60m below sea level to 3000m above sea level<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Relative Humidity<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Nonoperating Humidity: 95% RH<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Acoustic Noise Measured per ISO 7779 and Declared per ISO 9296 Bystander Positions Operating to an Ambient Temperature of 25&deg;C<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Industrial Product: 65 dBA maximum<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>RoHS<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Reduction of Hazardous Substances (ROHS) 5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"bottom\">\n<p align=\"center\"><strong>Power Supply<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>AC Power Max Rating<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>750W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>System Power Consumption<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>330W nominal\/400W max<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Input-Voltage Range and Frequency<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>AC 100 to 240 VAC 50-60 Hz\/DC -72 VDC to -40 VDC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>DC Power Max Rating<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>750W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>AC to DC failover and vice versa<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Total Output BTU (Note: 1000 BTU\/hr = 293W)<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>1122 BTU\/hr (330 W) nominal\/1365 BTU\/hr (400 W) max<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Input Current<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>AC 11A @ 110VAC, 6 A @ 200VAC\/DC 25A Max&nbsp;<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Output Ratings<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>12V @ 62A &amp; 3.3V @ 3A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Output Holdup Time<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>AC = 16 ms; DC = 4 ms @ maximum load<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Power-Supply Input Receptacles<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>AC IEC 60320 C15\/DC Custom detachable screw terminal (supplied)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Power Cord Rating<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>AC 15A\/DC 25A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"bottom\">\n<p align=\"center\"><strong>MTBF Information<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>WS-C4500X-24X-ES<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>209,330<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>WS-C4500X-40X-ES<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>199,720<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>WS-C4500X-F-16SFP+<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>209,330<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>WS-C4500X-F-32SFP+<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>199,720<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>C4KX-FAN-R<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>L10 Life 60,000 at 40C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"bottom\">\n<p align=\"center\"><strong>Regulatory Standards Compliance<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Regulatory Compliance<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>CE marking<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>EMI and EMC Compliance<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>47CFR Part 15 (CFR 47) Class A<\/p>\n<p>AS\/NZS CISPR22 Class A<\/p>\n<p>CISPR22 Class A<\/p>\n<p>EN55022 Class A<\/p>\n<p>ICES003 Class A<\/p>\n<p>VCCI Class A<\/p>\n<p>EN61000-3-2<\/p>\n<p>EN61000-3-3<\/p>\n<p>KN22 Class A<\/p>\n<p>CNS13438 Class A<\/p>\n<p>EN55024<\/p>\n<p>CISPR24<\/p>\n<p>EN300386<\/p>\n<p>KN24<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Safety Certifications<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>UL 60950-1 Second Edition<\/p>\n<p>CAN\/CSA-C22.2 No. 60950-1 Second Edition<\/p>\n<p>EN 60950-1 Second Edition<\/p>\n<p>IEC 60950-1 Second Edition<\/p>\n<p>AS\/NZS 60950-1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">\n<p>Industry EMC, Safety, and Environmental Standards<\/p>\n<\/td>\n<td valign=\"bottom\">\n<p>GR-63-Core Network Equipment Building Systems (NEBS) Level 3<\/p>\n<p>GR-1089-Core Level 3<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<table>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td itemprop=\"description\">Cisco Catalyst 4500-X 8 Port 10GE Ethernet port uplink Module C4KX-NM-8SFP+<\/td>\n<\/tr>\n<\/table>","protected":false},"featured_media":55437,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[648],"product_tag":[],"class_list":{"0":"post-12439","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-4500-switch-modules-cisco-modules-cards","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/12439","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=12439"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/55437"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=12439"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=12439"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=12439"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=12439"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}