{"id":12407,"date":"2025-09-29T11:31:40","date_gmt":"2025-09-29T11:31:40","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=12407"},"modified":"2025-09-29T11:31:41","modified_gmt":"2025-09-29T11:31:41","slug":"ws-x45-sup7l-e","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/ws-x45-sup7l-e\/","title":{"rendered":"WS-X45-SUP7L-E"},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<h3 align=\"center\"><strong>WS-X45-SUP7L-E Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<p align=\"center\"><strong>Feature<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Chassis compatibility<\/td>\n<td valign=\"top\">The Supervisor Engine\u00a07L-E is supported on the Catalyst 4503-E, Catalyst\u00a04506-E, Catalyst\u00a04507R-E, and the Catalyst\u00a04507R+E switch chassis. The Supervisor Engine\u00a07L-E is not supported on the Catalyst\u00a04510R-E or the Catalyst\u00a04510R+E switch chassis.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Software requirements (minimum)<\/td>\n<td valign=\"top\">Refer to your software release notes for the latest software release requirements.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Chassis slot restrictions<\/td>\n<td valign=\"top\">\u2022Catalyst 4503-E: Slot 1 only<\/p>\n<p>\u2022Catalyst 4506-E: Slot 1 only<\/p>\n<p>\u2022Catalyst 4507R-E and Catalyst 4507R+E: Slot 3 and slot 4<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Bandwidth per slot<\/td>\n<td valign=\"top\">48-Gbps<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\">Supervisor Engine\u00a07L-E Front Panel Features<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">STATUS LED<\/td>\n<td valign=\"top\">The STATUS LED indicates the current health of the supervisor engine and the current software state.<\/p>\n<p>\u2022Green\u2014All diagnostic tests have passed.<\/p>\n<p>\u2022Orange\u2014System boot or a diagnostic test is in progress.<\/p>\n<p>\u2022Red\u2014A diagnostic test failed.<\/p>\n<p>\u2022Off\u2014The supervisor engine is disabled or is not powered up.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">RESET switch<\/td>\n<td valign=\"top\">The RESET switch is used to reset and restart the switch.<\/p>\n<p>Note\u00a0Use a paper clip or other small, pointed object to press the RESET switch.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">ACTIVE SUP LED<\/td>\n<td valign=\"top\">The ACTIVE SUP LED indicates whether the supervisor engine is active or in standby mode in redundant supervisor engine configurations.<\/p>\n<p>\u2022Green\u2014Supervisor engine is active (in redundant supervisor engine configurations).<\/p>\n<p>\u2022Off\u2014Supervisor engine is in standby mode (in redundant supervisor engine configurations).<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">UTILIZATION LEDs<\/td>\n<td valign=\"top\">When the switch is operational, the eight UTILIZATION LEDs indicate the current traffic load over the backplane as an approximate percentage value. Each LED represents approximately 12.5\u00a0percent of load.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">USB connectors<\/td>\n<td valign=\"top\">Two USB 2.0 ports are provided:<\/p>\n<p>\u2022Port 1 is not supported at this time.<\/p>\n<p>\u2022Port 2 operates in host mode (downstream). It has a USB type A connector and a standard USB 2.0 device such as a flash memory device, can plug into this connector.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">SECURE DIGITAL slot<\/td>\n<td valign=\"top\">A standard Secure Data (SD) memory card interface is provided on the front panel.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">CONSOLE port<\/td>\n<td valign=\"top\">A 10\/100\/1000 port that uses an RJ-45 connector. The console port allows you to access the switch either locally (with a console terminal) or through a modem (remote). The port has an RJ-45 connector. The console port allows you to perform the following functions:<\/p>\n<p>\u2022Configure the switch from the CLI.<\/p>\n<p>\u2022Monitor network statistics and errors.<\/p>\n<p>\u2022Configure SNMP agent parameters.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">10\/100\/1000 MGT port<\/td>\n<td valign=\"top\">The Ethernet management port is a Layer 3 host port to which you can connect a PC. You can use the Ethernet management port instead of the switch console port for network management. When managing a switch, connect the PC to the Ethernet management port on a Catalyst\u00a04500 E-series switch.<\/p>\n<p>\u2022Green\u2014The link is operational.<\/p>\n<p>\u2022Orange\u2014The link is disabled by user.<\/p>\n<p>\u2022Flashing orange\u2014The power-on self-test indicates a faulty port.<\/p>\n<p>\u2022Off\u2014No signal is detected or there is a link configuration failure.<\/p>\n<p>Note\u00a0When connecting a PC to the Ethernet management port, you must assign an IP address.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">LINK LED<\/td>\n<td valign=\"top\">The 10\/100\/1000 MGT port has a LINK LED associated with it.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">UPLINK (SFP\/SFP+) ports<\/td>\n<td valign=\"top\">The Supervisor Engine\u00a07L-E has four uplink ports. Ports 1 and 2 support either 10GBASE SFP+ transceivers or 1000BASE SFP transceivers. Ports 3 and 4 support only 1000BASE SFP transceivers. There are restrictions on the use of the uplink ports in both single supervisor engine and redundant supervisor engine configurations and both 10-G and 1-G operation.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Uplink port LEDs<\/td>\n<td valign=\"top\">There are two types of LEDs associated with the supervisor engine uplink ports.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Uplink port ACTIVE LEDs<\/td>\n<td valign=\"top\">Uplink ports on the supervisor engine are active in pairs. Two LEDs on the front panel show this activity. One LED, labeled 1G\/10G 1-2 ACTIVE, indicates ports 1 and 2 are active; the other is labeled 1G 3-4 ACTIVE and indicates ports 3 and 4 are active.<\/p>\n<p>In standalone supervisor engine configurations operating in 1-Gigabit mode, all four uplink ports are active; both the 1-2 ACTIVE LED and 3-4 ACTIVE LED are lit green.<\/p>\n<p>In redundant supervisor engine configurations, only the 1-2 ACTIVE LED is lit green. When one supervisor engine is removed, both the 1-2 ACTIVE LED and 3-4 ACTIVE LED are lit green on the remaining supervisor engine when it is in 1-Gigabit operation. In 10-Gigabit mode, only the 1-2 ACTIVE LED is lit.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Uplink port STATUS LEDs<\/td>\n<td valign=\"top\">Uplink ports 1 and 2 each have two uplink port STATUS LEDs. The 1G LED displays port status when a 1-GB SFP transceiver is installed in the port socket. The 10G LED displays port status when a 10-GB SFP+ transceiver is installed in the port socket. Port 3 and Port 4 support only 1-GB SFP transceivers and have only the 1G port status LED.<\/p>\n<p>\u2022Green\u2014The link is operational.<\/p>\n<p>\u2022Orange\u2014The link is disabled by user.<\/p>\n<p>\u2022Flashing orange\u2014The power-on self-test indicates a faulty port.<\/p>\n<p>\u2022Off\u2014No signal is detected or there is a link configuration failure.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>&lt; tbody &gt;<\/p>\n<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>WS-X45-SUP7L-E Catalyst 4500 E-Series Supervisor Engine<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>Catalyst 4500 E-Series Supervisor Engine 7L-E &#8211; 520Gbps &#8211; VSS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Datasheet: <a href=\"https:\/\/gntme.com\/wp-content\/uploads\/2020\/05\/WS-X45-SUP7L-E-Datasheet.pdf\">WS-X45-SUP7L-E Datasheet<\/a><\/p>","protected":false},"featured_media":56782,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[648],"product_tag":[],"class_list":{"0":"post-12407","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-4500-switch-modules-cisco-modules-cards","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/12407","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=12407"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/56782"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=12407"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=12407"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=12407"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=12407"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}