{"id":11077,"date":"2025-09-29T11:20:55","date_gmt":"2025-09-29T11:20:55","guid":{"rendered":"https:\/\/greencode.ge\/?post_type=product&#038;p=11077"},"modified":"2025-09-29T11:20:56","modified_gmt":"2025-09-29T11:20:56","slug":"spa-4xct3-ds0","status":"publish","type":"product","link":"https:\/\/greencode.ge\/en\/product\/spa-4xct3-ds0\/","title":{"rendered":"SPA-4XCT3\/DS0"},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\">\n<h3 align=\"center\"><strong>SPA-4XCT3\/DS0 Specifications<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Product compatibility<\/strong><\/td>\n<td valign=\"top\">\u00b7\u00a0Cisco 7600 Series Routers<\/p>\n<p>\u00b7 Cisco ASR 1000 Series Aggregation Services Routers<\/p>\n<p>\u00b7 Cisco ASR 9000 Series Routers (4-port only)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Minimum software version<\/strong><\/td>\n<td valign=\"top\">\u00b7 Cisco 7600 Series Routers with Cisco IOS\u00ae\u00a0Software Release 15.4(2)S and Cisco IOS XE Software Release 3.12.0.0S<\/p>\n<p>\u00b7 Cisco ASR 1000 Series Router with Cisco IOS XE Software Release 3.12.0, 3.11.2, or 3.10.3<\/p>\n<p>\u00b7 Cisco ASR 9000 Series Router with Cisco IOS XR Software Release 5.2.0<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Port density per SPA<\/strong><\/td>\n<td valign=\"top\">4-port<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Physical interface<\/strong><\/td>\n<td valign=\"top\">\u00b7 1.0 and 2.3 RF connectors (75-ohm impedance)<\/p>\n<p>\u00b7 1.0 and 2.3 RF-to-BNC adapter cable option<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Protocols<\/strong><\/td>\n<td valign=\"top\">Serial encapsulations:<\/p>\n<p>\u00b7 High-Level Data Link Control (HDLC)<\/p>\n<p>\u00b7 Point-to-Point Protocol (PPP), RFC 1662<\/p>\n<p>\u00b7 Frame Relay, RFC 1490<\/p>\n<p>Multilink support (bundle limit dependent on number of links per bundle; maximum 12 T1 links per bundle)<\/p>\n<p>MLPPP, RFC 1990<\/p>\n<p>MLFR, FRF.16<\/p>\n<p>LFI over Frame Relay (FRF.12) and MLPPP<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Features and functions<\/strong><\/td>\n<td valign=\"top\">Up to 4 T3 ports<\/p>\n<p>\u00b7 Up to 112 T1 ports (28 T1 multiplexed onto a single T3)<\/p>\n<p>\u00b7 Up to 1024 n x DS-0 channels (where n is 1 to 24) with no T3 configured<\/p>\n<p>\u00b7 Up to 400 n x DS-0 channels (where n is 1 to 24) with one or more T3 configured<\/p>\n<p>\u00b7 Support for full-rate (clear channel) T3, Channelized T3 to T1, full-rate T1, Channelized T1, and fractional T1<\/p>\n<p>\u00b7 Integrated DSUs<\/p>\n<p>\u00b7 Internal or line-derived (loop) clocking selectable on each T3 or T1<\/p>\n<p>\u00b7 Loopback capabilities:<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Local and remote loopback at the T3 and T1 levels<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Response to embedded loopback commands<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Insertion of loopback commands into transmitted signal<\/p>\n<p>\u00b7 Bit-error-rate-testing (BERT) pattern generation and detection per channel<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Programmable pseudorandom pattern up to 32 bits long<\/p>\n<p>\u00b7 T3: All 0s, all 1s, 215, 220, 220 Quasi-Random Signal Sequence (QRSS), 223, alternating 0s and 1s, 1-in-8, and 3-in-24<\/p>\n<p>\u00b7 T1: All 0s, all 1s, 211, 215, 220, 220 QRSS, 223, alternating 0s and 1s, 1-in-8, and 3-in-24<\/p>\n<p>\u25e6\u00a0\u00a0\u00a032-bit error-count and bit-count registers<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Fully independent transmit and receive sections<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Detection of test patterns with bit error rates up to 10-2<\/p>\n<p>\u00b7 24-hour history maintained for error statistics and failure counts, at 15-minute intervals<\/p>\n<p>\u00b7 16- and 32-bit cyclic redundancy check (CRC); 16-bit default<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>T1-specific features<\/strong><\/td>\n<td valign=\"top\">\u00b7 Full-duplex connectivity at T1 rate (1.536 MHz)<\/p>\n<p>\u00b7 D4 Super Frame (SF) or Extended Super Frame (ESF) framing<\/p>\n<p>\u00b7 ANSI T1.403 and AT&amp;T TR 54016 Facility Data Link (FDL) support<\/p>\n<p>\u00b7 Alarm monitoring:<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Alarm indication signal (AIS)<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Out of frame (OOF)<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Far-end alarm failure (yellow or distant alarm)<\/p>\n<p>\u00b7 Performance data collection:<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0CRC and bit errors<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Framing bit errors (FERR)<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Line errored seconds<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Far-end errored seconds<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Far-end severely errored seconds<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Far-end unavailable seconds<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>T3-specific features<\/strong><\/td>\n<td valign=\"top\">\u00b7 Full-duplex connectivity at T3 rate (44.736 MHz)<\/p>\n<p>\u00b7 C-Bit or M23 framing<\/p>\n<p>\u00b7 Subrate and scrambling support of Quick Eagle Networks (formerly Digital Link), Larscom, ADC Kentrox, Adtran, and Verilink DSUs<\/p>\n<p>\u00b7 Binary 3-zero substitution (B3ZS) line coding<\/p>\n<p>\u00b7 Maintenance data link (MDL)<\/p>\n<p>\u00b7 T3 far-end alarm and control (FEAC) channel support<\/p>\n<p>\u00b7 Line build-out up to 450 ft (135m)<\/p>\n<p>\u00b7 Alarm monitoring:<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0AIS<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0OOF<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Loss of signal (LOS)<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Far-end receive failure (FERF)<\/p>\n<p>\u00b7 Performance data collection:<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Line coding violation (LCV)<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Framing bit errors (FERR) (F- or M-bit errors)<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0P-bit error counts (path-parity errors)<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0C-bit error counts<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Far-end block error (FEBE) counts<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Reliability and availability<\/strong><\/td>\n<td valign=\"top\">\u00b7 OIR<\/p>\n<p>\u00b7 Single SPA software reset<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>MIBs<\/strong><\/td>\n<td valign=\"top\">\u00b7 RFC 2495 MIB (DS-1\/E1 MIB)<\/p>\n<p>\u00b7 RFC 2496 MIB (DS-3 MIB)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Network management<\/strong><\/td>\n<td valign=\"top\">Simple Network Management Protocol (SNMP)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Physical specifications<\/strong><\/td>\n<td valign=\"top\">\u00b7 Weight: 0.75 lb (0.34 kg)<\/p>\n<p>\u00b7 Height: 0.8 in. (2.03 cm) (single height)<\/p>\n<p>\u00b7 Width: 6.75 in. (17.15 cm)<\/p>\n<p>\u00b7 Depth: 7.28 in. (18.49 cm)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Power<\/strong><\/td>\n<td valign=\"top\">\u00b7 2-port: 11.3W maximum<\/p>\n<p>\u00b7 4-port: 13.2W maximum<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Environmental specifications<\/strong><\/td>\n<td valign=\"top\">\u00b7 Operating temperature: 41 to 104\u00b0F (5 to 40\u00b0C)<\/p>\n<p>\u00b7 Storage temperature: \u201338 to 150\u00b0F (\u201340 to 70\u00b0C)<\/p>\n<p>\u00b7 Operating humidity: 5 to 85% relative humidity<\/p>\n<p>\u00b7 Storage humidity: 5 to 95% relative humidity<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Compliance and agency approvals<\/strong><\/td>\n<td valign=\"top\">CE Marking<\/p>\n<p>Safety<\/p>\n<p>\u00b7 UL 60950<\/p>\n<p>\u00b7 CSA 22.2 No.60950<\/p>\n<p>\u00b7 IEC 60950<\/p>\n<p>\u00b7 EN 60950<\/p>\n<p>\u00b7 AS\/NZS 3260<\/p>\n<p>\u00b7 TS001<\/p>\n<p>EMC<\/p>\n<p>\u00b7 CFR47 Part 15<\/p>\n<p>\u00b7 ICES 003<\/p>\n<p>\u00b7 EN55022<\/p>\n<p>\u00b7 CISPR 22<\/p>\n<p>\u00b7 AS\/NZ 3548<\/p>\n<p>\u00b7 VCCI<\/p>\n<p>\u00b7 EN55024<\/p>\n<p>\u00b7 EN50082-1<\/p>\n<p>\u00b7 EN61000-6-1<\/p>\n<p>Telecom (T3)<\/p>\n<p>\u00b7 ANSI T1 107<\/p>\n<p>\u00b7 T1 404<\/p>\n<p>\u00b7 AT&amp;T 54014<\/p>\n<p>\u00b7 ANSI T1.231<\/p>\n<p>Telecom (T1)<\/p>\n<p>\u00b7 ANSI T1.403<\/p>\n<p>\u00b7 AT&amp;T 54016<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>&lt; tbody &gt;<\/p>\n<table>\n<tbody>\n<tr>\n<td class=\"label\">Model:<\/td>\n<td>SPA-4XCT3\/DS0 Cisco ASR 9000 Series Shared Port Adapter<\/td>\n<\/tr>\n<tr>\n<td>Detail:<\/td>\n<td>Cisco ASR 9000 Adapter SPA-4XCT3\/DS0 4-port Channelized T3 to DS0 Shared Port Adapter<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":56459,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[546],"product_tag":[],"class_list":{"0":"post-11077","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco-router-asr-9000-cisco-routers","8":"first","9":"instock","10":"sale","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product\/11077","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/comments?post=11077"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media\/56459"}],"wp:attachment":[{"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/media?parent=11077"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_brand?post=11077"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_cat?post=11077"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greencode.ge\/en\/wp-json\/wp\/v2\/product_tag?post=11077"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}